OEM VERIFIED BENCH
OFFICIAL FAULT CODEEd
Rosieres
Rosieres // OFFICIAL DIAGNOSTIC BENCH

Rosieres Ed

DishwasherDrive Motor, Inverter & Tachometer Sensor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code Ed:HaierEDCandyEDHooverEDGEEDIbernaEDZerowattED

Symptom / Description

FAULT

Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Detergent dispenser actuator fault Ed; tablet door flap fails to trip open during primary wash cycle.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Rosières dishwashers powered by Grande Capacité built-in hydraulic circuit, triple-arm spray system, and acoustic soundproofing: Open dispenser wax motor or solenoid actuator coil (~1.5–3.0 kΩ), mechanical latch jam, or broken door wiring.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Remove inner door panel. Measure dispenser actuator coil resistance (~1.5–3.0 kΩ). Check spring-loaded flap latch for smooth movement. Press and hold Start/Cancel button for 6 seconds until all cycle lights extinguish, then switch off mains toggle switch.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Rosieres Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrive Motor, Inverter & Tachometer SensorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Test Pins & Connections
PROBE (+)
PROBE (-)
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Tolerance & Diagnostic CriteriaBLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol & DC Bus: Wait at least 5 minutes after power cutoff to allow inverter DC bus capacitors (380V DC) to bleed down.
  • !Verify 0V DC across inverter filter capacitors before unplugging motor harness connectors.
  • !Keep hands clear of drive belt and pulleys during any manual rotation tng.
3. Preliminary Mechanical & Visual Checks
  • Slip off drive belt and spin drum/motor shaft by hand to check for roaring or seized ball bearings.
  • For universal motors: verify carbon brushes have at least 10mm remaining length and smooth contact faces.
  • Inspect motor suspension rubber mounts and drive belt tension/groove profile.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Rosieres ED

FAQ TREE
What does error code ED mean on a Rosieres appliance?

Rosieres error code ED indicates: Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Detergent dispenser actuator fault Ed; tablet door flap fails to trip open during primary wash cycle..

What is the root cause of Rosieres error code ED?

The primary root cause for Rosieres code ED is: On Rosières dishwashers powered by Grande Capacité built-in hydraulic circuit, triple-arm spray system, and acoustic soundproofing: Open dispenser wax motor or solenoid actuator coil (~1.5–3.0 kΩ), mechanical latch jam, or broken door wiring..

How do I fix or resolve Rosieres error code ED?

To resolve error code ED: Remove inner door panel. Measure dispenser actuator coil resistance (~1.5–3.0 kΩ). Check spring-loaded flap latch for smooth movement. Press and hold Start/Cancel button for 6 seconds until all cycle lights extinguish, then switch off mains toggle switch.

Is it safe to clear Rosieres error code ED by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code ED persists, the physical component causing On Rosières dishwashers powered by Grande Capacité built-in hydraulic circuit, triple-arm spray system, and acoustic soundproofing: Open dispenser wax motor or solenoid actuator coil (~1.5–3.0 kΩ), mechanical latch jam, or broken door wiring. must be inspected or replaced.

How do I test electrical resistance for Rosieres code ED using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test 3-Phase Motor Windings / Tacho Generator / Carbon Brushes across Across phase pins U-V, V-W, U-W on motor harness; across tacho pins. Expected nominal reading is 3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator). Tolerance: BLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho..

What safety protocol must be followed before servicing Rosieres code ED?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ROSIÈRES

Related Rosières Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

EFWater Level Pressure Switch & Air Dome
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Flowmeter pulse overflow anomaly EF;...
Inspect Protocol
EhNTC Temperature Sensor & Thermistor
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Heating circuit safety thermal overh...
Inspect Protocol
ELWater Inlet Valve, Aquastop & Flowmeter
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Low incoming water pressure detected...
Inspect Protocol
AL03Drainage System & Drain Pump
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Drain evacuation alarm AL03; sump fa...
Inspect Protocol
AL05Water Level Pressure Switch & Air Dome
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Water filling timeout alarm AL05; wa...
Inspect Protocol
E01Water Inlet Valve, Aquastop & Flowmeter
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Water fill solenoid valve circuit fa...
Inspect Protocol
E02Water Inlet Valve, Aquastop & Flowmeter
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Fill meter pulse count error E02; tu...
Inspect Protocol
E03Drainage System & Drain Pump
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Drain pump evacuation timeout E03; w...
Inspect Protocol
E04Drainage System & Drain Pump
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Bottom tray anti-flood switch activa...
Inspect Protocol
E05NTC Temperature Sensor & Thermistor
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Water temperature sensor measurement...
Inspect Protocol
E06Electronic Control Board (PCB) & Bus Communications
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Main control board EEPROM verificati...
Inspect Protocol
E07Drive Motor, Inverter & Tachometer Sensor
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Circulation wash pump motor rotation...
Inspect Protocol
E08Heating Element, Thermostat & Safety Fuse
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Flow-through heater circuit open E08...
Inspect Protocol
E1Water Inlet Valve, Aquastop & Flowmeter
Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Water inlet fill failure E1; applian...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy