Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Rosieres AL05
FAQ TREEWhat does error code AL05 mean on a Rosieres appliance?
Rosieres error code AL05 indicates: Rosières RLI / RDS Grande Capacité Built-in Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit..
What is the root cause of Rosieres error code AL05?
The primary root cause for Rosieres code AL05 is: On Rosières dishwashers utilizing Grande Capacité built-in hydraulic circuit, triple-arm spray system, and acoustic soundproofing: Scaled water supply tap, blocked metal strainer mesh in inlet hose connector, or defective inlet valve (~3.5–4.5 kΩ)..
How do I fix or resolve Rosieres error code AL05?
To resolve error code AL05: Check faucet flow rate with bucket test. Remove supply hose and rinse out particulate debris from inlet filter. Measure valve solenoid (~3.5–4.5 kΩ). Press and hold Start/Cancel button for 6 seconds until all cycle lights extinguish, then switch off mains toggle switch.
Is it safe to clear Rosieres error code AL05 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code AL05 persists, the physical component causing On Rosières dishwashers utilizing Grande Capacité built-in hydraulic circuit, triple-arm spray system, and acoustic soundproofing: Scaled water supply tap, blocked metal strainer mesh in inlet hose connector, or defective inlet valve (~3.5–4.5 kΩ). must be inspected or replaced.
How do I test electrical resistance for Rosieres code AL05 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Rosieres code AL05?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?