Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEAL05
GE
GE // OFFICIAL DIAGNOSTIC BENCH

GE AL05

DishwasherWater Level Pressure Switch & Air Dome
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code AL05:HaierAL05CandyAL05HooverAL05SchulthessAL05RosieresAL05ArdoAL05IbernaAL05NovomaticAL05SangiorgioAL05SiltalAL05

Symptom / Description

FAULT

GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On GE dishwashers utilizing Cafe / Profile UltraFresh Microban wash filtration, dedicated deep clean silverware jets, and SmartHQ telemetry: Scaled water supply tap, blocked metal strainer mesh in inlet hose connector, or defective inlet valve (~3.5–4.5 kΩ).

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check faucet flow rate with bucket test. Remove supply hose and rinse out particulate debris from inlet filter. Measure valve solenoid (~3.5–4.5 kΩ). Press and hold Start button for 3 seconds to cancel cycle, wait 2 minutes for drain cycle to conclude, then power cycle.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide GE Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Level Pressure Switch & Air DomeDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Test Pins & Connections
PROBE (+)
PROBE (-)
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Tolerance & Diagnostic CriteriaMechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Cut 230V mains power before accessing the upper chassis or pressure switch terminals.
  • !Drain appliance tub completely before disconnecting pressure switch sensing hoses.
  • !Never blow high-pressure compressed air into electronic analog pressure sensors: internal diaphragms will rupture!
3. Preliminary Mechanical & Visual Checks
  • Disconnect the silicone pressure tube from the lower air trap and inspect for soap sludge, lint, or water blockage.
  • Inspect the flexible rubber hose along its entire length for pinholes, cracks, or loose clamp fit.
  • Thoroughly flush the lower compression chamber (air dome) with hot water to dissolve detergent buildup.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: GE AL05

FAQ TREE
What does error code AL05 mean on a GE appliance?

GE error code AL05 indicates: GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit..

What is the root cause of GE error code AL05?

The primary root cause for GE code AL05 is: On GE dishwashers utilizing Cafe / Profile UltraFresh Microban wash filtration, dedicated deep clean silverware jets, and SmartHQ telemetry: Scaled water supply tap, blocked metal strainer mesh in inlet hose connector, or defective inlet valve (~3.5–4.5 kΩ)..

How do I fix or resolve GE error code AL05?

To resolve error code AL05: Check faucet flow rate with bucket test. Remove supply hose and rinse out particulate debris from inlet filter. Measure valve solenoid (~3.5–4.5 kΩ). Press and hold Start button for 3 seconds to cancel cycle, wait 2 minutes for drain cycle to conclude, then power cycle.

Is it safe to clear GE error code AL05 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if GE code AL05 persists, the physical component causing On GE dishwashers utilizing Cafe / Profile UltraFresh Microban wash filtration, dedicated deep clean silverware jets, and SmartHQ telemetry: Scaled water supply tap, blocked metal strainer mesh in inlet hose connector, or defective inlet valve (~3.5–4.5 kΩ). must be inspected or replaced.

How do I test electrical resistance for GE code AL05 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..

What safety protocol must be followed before servicing GE code AL05?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // GE

Related GE Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E01Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Water fill solenoid valve circuit...
Inspect Protocol
E02Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Fill meter pulse count error E02;...
Inspect Protocol
E03Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Drain pump evacuation timeout E03...
Inspect Protocol
E04Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Bottom tray anti-flood switch act...
Inspect Protocol
E05NTC Temperature Sensor & Thermistor
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Water temperature sensor measurem...
Inspect Protocol
E06Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Main control board EEPROM verific...
Inspect Protocol
E07Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Circulation wash pump motor rotat...
Inspect Protocol
E08Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Flow-through heater circuit open ...
Inspect Protocol
E1Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Water inlet fill failure E1; appl...
Inspect Protocol
E10Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Water diverter valve timeout E10;...
Inspect Protocol
E12Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Software sequence logic fault E12...
Inspect Protocol
E14Water Level Pressure Switch & Air Dome
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Flowmeter signal missing during f...
Inspect Protocol
E15Water Level Pressure Switch & Air Dome
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Spray arm rotation / water pressu...
Inspect Protocol
E16Drainage System & Drain Pump
GE Profile / Cafe UltraFresh Microban Built-in Dishwasher: Water softener regeneration valve...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy