OFFICIAL FAULT CODEAL05
Atlantic
Atlantic // OFFICIAL DIAGNOSTIC BENCH

Atlantic AL05

BoilerNTC Temperature Sensor & Thermistor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Boiler
Other Brands Sharing Code AL05:HaierAL05CandyAL05HooverAL05SchulthessAL05RosieresAL05ArdoAL05GEAL05IbernaAL05NovomaticAL05RiberAL05

Symptom / Description

FAULT

Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic fault code AL05 registered by the microcomputer controller. Premix combustion air fan motor speed or tachometer feedback failure

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Atlantic appliances engineered with Siemens gas burner management microcomputer, stainless steel premix condensing heat exchanger, flame rectification ionization electrode (≥ 3.0 µA DC), and 10 kΩ primary heating NTC thermistors: premix combustion fan brushless motor bearing seizure or Hall effect tachometer feedback open circuit Metrological tolerance verification: supply 230V AC or 24V DC; tachometer square wave 0V-5V DC proportional to blower RPM.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check motor supply voltage and measure frequency / square wave output of tachometer wire. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the illuminated 'Reset' button on the boiler fascia for 3 to 5 seconds until 'rSt' flashes on the digital display and burner pre-purge begins. If lockout repeats, verify gas cock is fully open and inlet pressure is 20 mbar natural gas / 37 mbar propane before further resets.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Atlantic Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorWater Heater / Boiler
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Atlantic AL05

FAQ TREE
What does error code AL05 mean on a Atlantic appliance?

Atlantic error code AL05 indicates: Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic fault code AL05 registered by the microcomputer controller. Premix combustion air fan motor speed or tachometer feedback failure.

What is the root cause of Atlantic error code AL05?

The primary root cause for Atlantic code AL05 is: On Atlantic appliances engineered with Siemens gas burner management microcomputer, stainless steel premix condensing heat exchanger, flame rectification ionization electrode (≥ 3.0 µA DC), and 10 kΩ primary heating NTC thermistors: premix combustion fan brushless motor bearing seizure or Hall effect tachometer feedback open circuit Metrological tolerance verification: supply 230V AC or 24V DC; tachometer square wave 0V-5V DC proportional to blower RPM..

How do I fix or resolve Atlantic error code AL05?

To resolve error code AL05: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check motor supply voltage and measure frequency / square wave output of tachometer wire. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the illuminated 'Reset' button on the boiler fascia for 3 to 5 seconds until 'rSt' flashes on the digital display and burner pre-purge begins. If lockout repeats, verify gas cock is fully open and inlet pressure is 20 mbar natural gas / 37 mbar propane before further resets.

Is it safe to clear Atlantic error code AL05 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code AL05 persists, the physical component causing On Atlantic appliances engineered with Siemens gas burner management microcomputer, stainless steel premix condensing heat exchanger, flame rectification ionization electrode (≥ 3.0 µA DC), and 10 kΩ primary heating NTC thermistors: premix combustion fan brushless motor bearing seizure or Hall effect tachometer feedback open circuit Metrological tolerance verification: supply 230V AC or 24V DC; tachometer square wave 0V-5V DC proportional to blower RPM. must be inspected or replaced.

How do I test electrical resistance for Atlantic code AL05 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Atlantic code AL05?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ATLANTIC

Related Atlantic Water Heater / Boiler Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

AL06NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
AL07NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
AL08NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E01NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E02NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E03NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E04NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E07NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E12NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E25NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
E35NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
F1NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
F2NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
F22NTC Temperature Sensor & Thermistor
Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic faul...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy