Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Atlantic E25
FAQ TREEWhat does error code E25 mean on a Atlantic appliance?
Atlantic error code E25 indicates: Circulation fault or pump blockage.
What is the root cause of Atlantic error code E25?
The primary root cause for Atlantic code E25 is: Primary water circulation is poor. The pump may be blocked or has failed..
How do I fix or resolve Atlantic error code E25?
To resolve error code E25: Check if radiator valves are open. Inspect the central heating pump for blockages or failure.
Is it safe to clear Atlantic error code E25 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code E25 persists, the physical component causing Primary water circulation is poor. The pump may be blocked or has failed. must be inspected or replaced.
How do I test electrical resistance for Atlantic code E25 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..
What safety protocol must be followed before servicing Atlantic code E25?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?