Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Atlantic AL06
FAQ TREEWhat does error code AL06 mean on a Atlantic appliance?
Atlantic error code AL06 indicates: Boiler lockout related to flue safety.
What is the root cause of Atlantic error code AL06?
The primary root cause for Atlantic code AL06 is: The flue gas temperature sensor (probe) has detected an issue or has failed..
How do I fix or resolve Atlantic error code AL06?
To resolve error code AL06: Ensure the flue is not blocked. If the flue is clear, the sensor itself may be faulty and require replacement.
Is it safe to clear Atlantic error code AL06 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code AL06 persists, the physical component causing The flue gas temperature sensor (probe) has detected an issue or has failed. must be inspected or replaced.
How do I test electrical resistance for Atlantic code AL06 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Atlantic code AL06?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?