OFFICIAL FAULT CODEAL06
Atlantic
Atlantic // OFFICIAL DIAGNOSTIC BENCH

Atlantic AL06

BoilerNTC Temperature Sensor & Thermistor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Boiler
Other Brands Sharing Code AL06:SiltalAL06

Symptom / Description

FAULT

Boiler lockout related to flue safety

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The flue gas temperature sensor (probe) has detected an issue or has failed.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Ensure the flue is not blocked. If the flue is clear, the sensor itself may be faulty and require replacement.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Atlantic Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorWater Heater / Boiler
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Atlantic AL06

FAQ TREE
What does error code AL06 mean on a Atlantic appliance?

Atlantic error code AL06 indicates: Boiler lockout related to flue safety.

What is the root cause of Atlantic error code AL06?

The primary root cause for Atlantic code AL06 is: The flue gas temperature sensor (probe) has detected an issue or has failed..

How do I fix or resolve Atlantic error code AL06?

To resolve error code AL06: Ensure the flue is not blocked. If the flue is clear, the sensor itself may be faulty and require replacement.

Is it safe to clear Atlantic error code AL06 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code AL06 persists, the physical component causing The flue gas temperature sensor (probe) has detected an issue or has failed. must be inspected or replaced.

How do I test electrical resistance for Atlantic code AL06 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Atlantic code AL06?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ATLANTIC

Related Atlantic Water Heater / Boiler Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E01Drainage System & Drain Pump
Ignition failure, boiler will not start
Inspect Protocol
E02Heating Element, Thermostat & Safety Fuse
Boiler overheated and locked out
Inspect Protocol
E03Water Level Pressure Switch & Air Dome
Atlantic E03: Water level pressure sensor/switch frequency anomaly detected in Water Heater ...
Inspect Protocol
E04Water Level Pressure Switch & Air Dome
Atlantic E04: Water inlet / filling timeout in Water Heater / Boiler; appliance fails to fil...
Inspect Protocol
E25Heating Element, Thermostat & Safety Fuse
Circulation fault or pump blockage
Inspect Protocol
E35Heating Element, Thermostat & Safety Fuse
Atlantic E35: Operational cycle fault detected during Water Heater / Boiler program execution.
Inspect Protocol
F1Heating Element, Thermostat & Safety Fuse
Atlantic F1: Water/air heating failure in Water Heater / Boiler; heating circuit does not re...
Inspect Protocol
F2NTC Temperature Sensor & Thermistor
Atlantic F2: NTC temperature sensor signal out of range (open or short circuit) in Water Hea...
Inspect Protocol
F22Water Inlet Valve, Aquastop & Flowmeter
Low water pressure warning
Inspect Protocol
F3NTC Temperature Sensor & Thermistor
Atlantic F3: NTC temperature sensor signal out of range (open or short circuit) in Water Hea...
Inspect Protocol
F37General System & Mechanical Integration
Incorrect system water pressure
Inspect Protocol
F4Heating Element, Thermostat & Safety Fuse
Atlantic F4: Operational cycle fault detected during Water Heater / Boiler program execution.
Inspect Protocol
F5Water Level Pressure Switch & Air Dome
Air pressure switch or fan fault
Inspect Protocol
AL01Water Inlet Valve, Aquastop & Flowmeter
Boiler operation stopped, low pressure alert
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy