DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Atlantic E07
FAQ TREEWhat does error code E07 mean on a Atlantic appliance?
Atlantic error code E07 indicates: Atlantic Naema / Perfinox / Effinox / Varmax Gas Condensing & Hybrid Boiler: Diagnostic fault code E07 registered by the microcomputer controller. Outdoor weather compensation temperature sensor open or short circuit.
What is the root cause of Atlantic error code E07?
The primary root cause for Atlantic code E07 is: On Atlantic appliances engineered with Siemens gas burner management microcomputer, stainless steel premix condensing heat exchanger, flame rectification ionization electrode (≥ 3.0 µA DC), and 10 kΩ primary heating NTC thermistors: outdoor weather compensation temperature sensor cable severed, terminal oxidation, or QAC34 probe failed Metrological tolerance verification: Siemens QAC34 NTC 1.0 kΩ at 25°C or standard NTC 10 kΩ at 25°C..
How do I fix or resolve Atlantic error code E07?
To resolve error code E07: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure DC resistance at boiler terminal block; check for cable damage or moisture ingress in outdoor enclosure. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the illuminated 'Reset' button on the boiler fascia for 3 to 5 seconds until 'rSt' flashes on the digital display and burner pre-purge begins. If lockout repeats, verify gas cock is fully open and inlet pressure is 20 mbar natural gas / 37 mbar propane before further resets.
Is it safe to clear Atlantic error code E07 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code E07 persists, the physical component causing On Atlantic appliances engineered with Siemens gas burner management microcomputer, stainless steel premix condensing heat exchanger, flame rectification ionization electrode (≥ 3.0 µA DC), and 10 kΩ primary heating NTC thermistors: outdoor weather compensation temperature sensor cable severed, terminal oxidation, or QAC34 probe failed Metrological tolerance verification: Siemens QAC34 NTC 1.0 kΩ at 25°C or standard NTC 10 kΩ at 25°C. must be inspected or replaced.
How do I test electrical resistance for Atlantic code E07 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Atlantic code E07?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?