OEM VERIFIED BENCH
OFFICIAL FAULT CODEAL02
Atlantic
Atlantic // OFFICIAL DIAGNOSTIC BENCH

Atlantic AL02

BoilerGeneral System & Mechanical Integration
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Boiler
Other Brands Sharing Code AL02:MieleAL02BauknechtAL02V-ZugAL02De DietrichAL02LiebherrAL02GaggenauAL02SchulthessAL02FAGORAL02RosieresAL02SauterAL02

Symptom / Description

FAULT

Problem with domestic hot water temperature

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The domestic hot water (DHW) sensor (probe) is faulty or has a bad connection.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check the connection of the DHW probe. If the connection is good, the probe will need to be tested and likely replaced.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Atlantic Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLGeneral System & Mechanical IntegrationWater Heater / Boiler
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Protective Earth Bonding & Incoming Mains Voltage
Test Pins & Connections
PROBE (+)
PROBE (-)
Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N
Tolerance & Diagnostic CriteriaProtective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical mains plug or trip dedicated circuit breaker before servicing.
  • !Wait at least 5 minutes before opening any casing panels to reset volatile microcontrollers and bleed residual charges.
  • !Operate in a dry workshop environment; never bypass internal electrical thermal cutouts.
3. Preliminary Mechanical & Visual Checks
  • Check appliance leveling with a spirit level; adjust threaded leveling feet for perfect stability.
  • Check door and lid perimeter rubber gaskets for tears, gaps, or foreign object obstruction.
  • Inspect shock absorbers, suspension springs, and rubber dampers for mechanical fatigue or excessive play.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Atlantic AL02

FAQ TREE
What does error code AL02 mean on a Atlantic appliance?

Atlantic error code AL02 indicates: Problem with domestic hot water temperature.

What is the root cause of Atlantic error code AL02?

The primary root cause for Atlantic code AL02 is: The domestic hot water (DHW) sensor (probe) is faulty or has a bad connection..

How do I fix or resolve Atlantic error code AL02?

To resolve error code AL02: Check the connection of the DHW probe. If the connection is good, the probe will need to be tested and likely replaced.

Is it safe to clear Atlantic error code AL02 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code AL02 persists, the physical component causing The domestic hot water (DHW) sensor (probe) is faulty or has a bad connection. must be inspected or replaced.

How do I test electrical resistance for Atlantic code AL02 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Protective Earth Bonding & Incoming Mains Voltage across Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N. Expected nominal reading is Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.. Tolerance: Protective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load..

What safety protocol must be followed before servicing Atlantic code AL02?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ATLANTIC

Related Atlantic Water Heater / Boiler Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

AL03Heating Element, Thermostat & Safety Fuse
Problem with central heating temperature
Inspect Protocol
AL06NTC Temperature Sensor & Thermistor
Boiler lockout related to flue safety
Inspect Protocol
E01Drainage System & Drain Pump
Ignition failure, boiler will not start
Inspect Protocol
E02Heating Element, Thermostat & Safety Fuse
Boiler overheated and locked out
Inspect Protocol
E03Water Level Pressure Switch & Air Dome
Atlantic E03: Water level pressure sensor/switch frequency anomaly detected in Water Heater ...
Inspect Protocol
E04Water Level Pressure Switch & Air Dome
Atlantic E04: Water inlet / filling timeout in Water Heater / Boiler; appliance fails to fil...
Inspect Protocol
E25Heating Element, Thermostat & Safety Fuse
Circulation fault or pump blockage
Inspect Protocol
E35Heating Element, Thermostat & Safety Fuse
Atlantic E35: Operational cycle fault detected during Water Heater / Boiler program execution.
Inspect Protocol
F1Heating Element, Thermostat & Safety Fuse
Atlantic F1: Water/air heating failure in Water Heater / Boiler; heating circuit does not re...
Inspect Protocol
F2NTC Temperature Sensor & Thermistor
Atlantic F2: NTC temperature sensor signal out of range (open or short circuit) in Water Hea...
Inspect Protocol
F22Water Inlet Valve, Aquastop & Flowmeter
Low water pressure warning
Inspect Protocol
F3NTC Temperature Sensor & Thermistor
Atlantic F3: NTC temperature sensor signal out of range (open or short circuit) in Water Hea...
Inspect Protocol
F37General System & Mechanical Integration
Incorrect system water pressure
Inspect Protocol
F4Heating Element, Thermostat & Safety Fuse
Atlantic F4: Operational cycle fault detected during Water Heater / Boiler program execution.
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy