Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF10
Indesit
Indesit // OFFICIAL DIAGNOSTIC BENCH

Indesit Dishwasher F10

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Whirlpool / Indesit Group: Equivalent Code Across OEM Group Brands
Whirlpool / Indesit Global Electronic Architecture
WhirlpoolF10AristonF10HotpointF10BauknechtF10IgnisF10MaytagF10
Other Brands Sharing Code F10:MieleF10BrandtF10De DietrichF10LiebherrF10SchulthessF10SauterF10ScholtèsF10

Symptom / Description

FAULT

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Heating circuit safety relay stuck open F10; DEA700 power module fails to close high-current heater contact.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Indesit dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Inspect DEA700 power module for burned solder pads under heater relay. Measure relay coil continuity (nominal 350–450 Ω). Replace power board if relay damaged. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Indesit Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Indesit F10

FAQ TREE
What does error code F10 mean on a Indesit appliance?

Indesit error code F10 indicates: Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Heating circuit safety relay stuck open F10; DEA700 power module fails to close high-current heater contact..

What is the root cause of Indesit error code F10?

The primary root cause for Indesit code F10 is: On Indesit dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop..

How do I fix or resolve Indesit error code F10?

To resolve error code F10: Inspect DEA700 power module for burned solder pads under heater relay. Measure relay coil continuity (nominal 350–450 Ω). Replace power board if relay damaged. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Is it safe to clear Indesit error code F10 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Indesit code F10 persists, the physical component causing On Indesit dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop. must be inspected or replaced.

How do I test electrical resistance for Indesit code F10 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Indesit code F10?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Indesit error code F10 mean on a Dishwasher?

Indesit error code F10 on a Dishwasher indicates: Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Heating circuit safety relay stuck open F10; DEA700 power module fails to close high-current heater contact.. Primary cause: On Indesit dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop.. Recommended solution: Inspect DEA700 power module for burned solder pads under heater relay. Measure relay coil continuity (nominal 350–450 Ω). Replace power board if relay damaged. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF..

What does Indesit error code F10 mean on a Tumble Dryer?

Indesit error code F10 on a Tumble Dryer indicates: Indesit MyTime & Push&Go Condenser Tumble Dryer: Motor control module thermal cutoff activation F10; MCU inverter temperature exceeds safe operating threshold (> 85°C).. Primary cause: On Indesit tumble dryers: Blocked lower air cooling intake vents, heavy lint accumulation over electronics heatsink, or bearing friction on motor shaft.. Recommended solution: Clean base ventilation grilles. Vacuum lint from inverter heatsink fins. Check motor shaft for free spin without radial play. Allow unit to cool 30 minutes. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter..

What does Indesit error code F10 mean on a Oven?

Indesit error code F10 on a Oven indicates: Indesit Aria & Turn&Cook Multifunction Oven: Cavity slow heating rate or temperature drift F10; cavity fails to climb by at least 50°C within 15 minutes of heating startup.. Primary cause: On Indesit ovens: Defective circular fan heating element (convection ring element open), degraded door perimeter gasket, or low mains supply voltage (< 205V).. Recommended solution: Inspect circular convection heating element (nominal 24–32 Ω, ~2000W). Check door gasket seal integrity with paper strip test. Verify 230V mains voltage under load. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer..

What does Indesit error code F10 mean on a Washing Machine?

Indesit error code F10 on a Washing Machine indicates: Indesit Innex & Push&Go MyTime Washing Machine: Motor control unit thermal cutoff F10; MCU inverter heatsink temperature sensor detects overheating or pressure state conflict.. Primary cause: On Indesit washing appliances: Inadequate heatsink ventilation, excessive drum friction from bearing failure, or degraded thermal paste on IPM inverter module.. Recommended solution: Inspect drum rotation by hand for bearing drag. Check MCU heatsink for dust buildup and renew thermal paste on IPM module. Verify motor phase balance (6.5–8.5 Ω). Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Indesit F10 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Indesit F10 — Dishwasher

[ACTIVE]
Symptom / Description:

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Heating circuit safety relay stuck open F10; DEA700 power module fails to close high-current heater contact.

Root Cause:

On Indesit dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop.

Repair Instructions:

Inspect DEA700 power module for burned solder pads under heater relay. Measure relay coil continuity (nominal 350–450 Ω). Replace power board if relay damaged. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Indesit F10 — Dryer

Symptom / Description:

Indesit MyTime & Push&Go Condenser Tumble Dryer: Motor control module thermal cutoff activation F10; MCU inverter temperature exceeds safe operating threshold (> 85°C).

Root Cause:

On Indesit tumble dryers: Blocked lower air cooling intake vents, heavy lint accumulation over electronics heatsink, or bearing friction on motor shaft.

Repair Instructions:

Clean base ventilation grilles. Vacuum lint from inverter heatsink fins. Check motor shaft for free spin without radial play. Allow unit to cool 30 minutes. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Indesit F10 — Oven

Symptom / Description:

Indesit Aria & Turn&Cook Multifunction Oven: Cavity slow heating rate or temperature drift F10; cavity fails to climb by at least 50°C within 15 minutes of heating startup.

Root Cause:

On Indesit ovens: Defective circular fan heating element (convection ring element open), degraded door perimeter gasket, or low mains supply voltage (< 205V).

Repair Instructions:

Inspect circular convection heating element (nominal 24–32 Ω, ~2000W). Check door gasket seal integrity with paper strip test. Verify 230V mains voltage under load. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Indesit F10 — Washing Machine

Symptom / Description:

Indesit Innex & Push&Go MyTime Washing Machine: Motor control unit thermal cutoff F10; MCU inverter heatsink temperature sensor detects overheating or pressure state conflict.

Root Cause:

On Indesit washing appliances: Inadequate heatsink ventilation, excessive drum friction from bearing failure, or degraded thermal paste on IPM inverter module.

Repair Instructions:

Inspect drum rotation by hand for bearing drag. Check MCU heatsink for dust buildup and renew thermal paste on IPM module. Verify motor phase balance (6.5–8.5 Ω). Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

SEMANTIC KNOWLEDGE GRAPH // INDESIT

Related Indesit Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F11Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: BLDC circulation pump inverter drive ...
Inspect Protocol
F12Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Power PCB to user display communicati...
Inspect Protocol
F13Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Detergent dispenser actuator triac fa...
Inspect Protocol
F14Dishwasher
Water Level Pressure Switch & Air Dome
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Virtual water level sensor calculatio...
Inspect Protocol
F15Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Circulation pump motor Hall sensor di...
Inspect Protocol
F2Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: AquaStop base tray leak detected F2; ...
Inspect Protocol
F3Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Wash heating system failure F3; wash ...
Inspect Protocol
F4Dishwasher
Water Level Pressure Switch & Air Dome
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Draining timeout failure F4; water le...
Inspect Protocol
F5Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Wash rotor stalled or low spray press...
Inspect Protocol
F6Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Water inlet tap closed error F6; insu...
Inspect Protocol
F7Dishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Flowmeter turbine sensor impulse faul...
Inspect Protocol
F8Dishwasher
Water Level Pressure Switch & Air Dome
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Sump water level inconsistency or div...
Inspect Protocol
F9Dishwasher
Water Level Pressure Switch & Air Dome
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Continuous water fill detected F9; in...
Inspect Protocol
FADishwasher
Drainage System & Drain Pump
Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Optical Water Indicator (OWI) turbidi...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy