Ocean F10 — Dishwasher
[ACTIVE]Ocean Oceanica / AquaStop Electronic Built-in & Freestanding Dishwasher: Diagnostic fault code F10 registered by the microcomputer controller. Wash water sump temperature NTC thermistor circuit open or shorted, heating regulation halted
System architecture (Ocean wash module, synchronous circulation pump, 1800W flow-through heater, and float safety microswitch): cracked NTC thermistor sensor pill, water ingress into sensor casing, or broken tub wire lead. Metrological test specification: NTC thermistor resistance 15.0 kΩ at 20°C, 12.0 kΩ at 25°C, 2.1 kΩ at 65°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: disconnect NTC plug from sump base; measure resistance across sensor pins with digital multimeter (~15 kΩ). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: press and hold the Program / Reset button for 5 seconds until the status indicator turns off and the drain pump runs for 30 seconds to evacuate residual water.