Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEi30
Philco
Philco // OFFICIAL DIAGNOSTIC BENCH

Philco i30

DishwasherWater Inlet Valve, Aquastop & Flowmeter
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code i30:ElectroluxI30AEGI30V-ZugI30ZanussiI30Arthur MartinI30SchulthessI30FAGORI30Schaub LorenzI30AirluxI30AtlanticI30

Symptom / Description

FAULT

Leakage / Anti-flood system activated

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The safety system in the base of the dishwasher has detected a water leak.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Turn off the water and power supply. The machine will need to be pulled out to find and fix the source of the internal leak.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Philco Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Inlet Valve, Aquastop & FlowmeterDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Solenoid Valve Coil / Aquastop Pneumatic Valve
Test Pins & Connections
PROBE (+)
PROBE (-)
Across coil spade terminals (disconnect harness first)
Tolerance & Diagnostic Criteria±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical power before touching solenoid valve coils or Aquastop connectors.
  • !Firmly shut off the domc water supply tap before unscrewing the inlet hose fitting.
  • !Check safety base drip tray for accumulated water triggering the anti-flood polystyrene float switch.
3. Preliminary Mechanical & Visual Checks
  • Remove and clean sediment and sand particles from the 3/4" inlet hose metal mesh filter.
  • Verify domestic dynamic water pressure is between 1.0 and 10.0 bar (0.1 to 1.0 MPa).
  • Inspect outer Aquastop hose jacket for expansion, pinch damage, or internal leak reservoir triggering.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Philco I30

FAQ TREE
What does error code I30 mean on a Philco appliance?

Philco error code I30 indicates: Leakage / Anti-flood system activated.

What is the root cause of Philco error code I30?

The primary root cause for Philco code I30 is: The safety system in the base of the dishwasher has detected a water leak..

How do I fix or resolve Philco error code I30?

To resolve error code I30: Turn off the water and power supply. The machine will need to be pulled out to find and fix the source of the internal leak.

Is it safe to clear Philco error code I30 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Philco code I30 persists, the physical component causing The safety system in the base of the dishwasher has detected a water leak. must be inspected or replaced.

How do I test electrical resistance for Philco code I30 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..

What safety protocol must be followed before servicing Philco code I30?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // PHILCO

Related Philco Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

i44Water Level Pressure Switch & Air Dome
Philco I44: Water level pressure sensor/switch frequency anomaly detected in Dishwasher.
Inspect Protocol
i50Drive Motor, Inverter & Tachometer Sensor
Philco I50: Motor drive or inverter rotation anomaly in Dishwasher; drum/motor fails to spin...
Inspect Protocol
i60NTC Temperature Sensor & Thermistor
Philco I60: NTC temperature sensor signal out of range (open or short circuit) in Dishwasher.
Inspect Protocol
iC0Electronic Control Board (PCB) & Bus Communications
Philco IC0: Operational cycle fault detected during Dishwasher program execution.
Inspect Protocol
AL03Heating Element, Thermostat & Safety Fuse
Philco AL03: Water/air heating failure in Dishwasher; heating circuit does not reach set tem...
Inspect Protocol
i10Water Level Pressure Switch & Air Dome
Philco I10: Water inlet / filling timeout in Dishwasher; appliance fails to fill to minimum ...
Inspect Protocol
i20Drainage System & Drain Pump
Philco I20: Water drainage failure detected in Dishwasher; drain pump cannot evacuate water ...
Inspect Protocol
LDoor Lock Mechanism & Safety Interlock
Philco L: Door lock safety interlock fault in Hob / Cooktop; door switch contact fails to cl...
Inspect Protocol
OPNTC Temperature Sensor & Thermistor
Open sensor circuit (Freezer)
Inspect Protocol
SHNTC Temperature Sensor & Thermistor
Shorted sensor circuit (Fridge)
Inspect Protocol
STOPGeneral System & Mechanical Integration
Pyrolytic cleaning cycle stopped
Inspect Protocol
UDrive Motor, Inverter & Tachometer Sensor
Unsuitable cookware detected
Inspect Protocol
EElectronic Control Board (PCB) & Bus Communications
General sensor or communication error
Inspect Protocol
E1NTC Temperature Sensor & Thermistor
Refrigerator compartment sensor fault
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy