OFFICIAL FAULT CODEi30
Atlantic
Atlantic // OFFICIAL DIAGNOSTIC BENCH

Atlantic i30

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code i30:ElectroluxI30AEGI30V-ZugI30ZanussiI30Arthur MartinI30SchulthessI30FAGORI30Schaub LorenzI30AirluxI30CastorI30

Symptom / Description

FAULT

Dishwasher has stopped and may be beeping continuously

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

Anti-flood device has been activated due to a leak in the base of the machine.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Turn off water and power supply. Tilt the machine to drain water from the base. Find and repair the source of the leak.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Atlantic Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Atlantic I30

FAQ TREE
What does error code I30 mean on a Atlantic appliance?

Atlantic error code I30 indicates: Dishwasher has stopped and may be beeping continuously.

What is the root cause of Atlantic error code I30?

The primary root cause for Atlantic code I30 is: Anti-flood device has been activated due to a leak in the base of the machine..

How do I fix or resolve Atlantic error code I30?

To resolve error code I30: Turn off water and power supply. Tilt the machine to drain water from the base. Find and repair the source of the leak.

Is it safe to clear Atlantic error code I30 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Atlantic code I30 persists, the physical component causing Anti-flood device has been activated due to a leak in the base of the machine. must be inspected or replaced.

How do I test electrical resistance for Atlantic code I30 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Atlantic code I30?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ATLANTIC

Related Atlantic Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E21Drainage System & Drain Pump
Water is not draining or draining too slowly
Inspect Protocol
E3NTC Temperature Sensor & Thermistor
Dishes are still dirty and wet after cycle / Water is cold
Inspect Protocol
E4Water Level Pressure Switch & Air Dome
Dishwasher has too much water inside / Overfills
Inspect Protocol
F11Drive Motor, Inverter & Tachometer Sensor
Wash motor or circulation pump error
Inspect Protocol
F12Water Inlet Valve, Aquastop & Flowmeter
No water entering the appliance
Inspect Protocol
F6Drive Motor, Inverter & Tachometer Sensor
Poor cleaning performance, usually on one rack
Inspect Protocol
i20Drainage System & Drain Pump
Water left in the bottom of dishwasher after cycle
Inspect Protocol
AL01Water Inlet Valve, Aquastop & Flowmeter
Boiler operation stopped, low pressure alert
Inspect Protocol
AL02General System & Mechanical Integration
Problem with domestic hot water temperature
Inspect Protocol
AL03Heating Element, Thermostat & Safety Fuse
Problem with central heating temperature
Inspect Protocol
AL06NTC Temperature Sensor & Thermistor
Boiler lockout related to flue safety
Inspect Protocol
E01Drainage System & Drain Pump
Ignition failure, boiler will not start
Inspect Protocol
E02Heating Element, Thermostat & Safety Fuse
Boiler overheated and locked out
Inspect Protocol
E03Water Level Pressure Switch & Air Dome
Atlantic E03: Water level pressure sensor/switch frequency anomaly detected in Water Heater ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy