Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Philco I60
FAQ TREEWhat does error code I60 mean on a Philco appliance?
Philco error code I60 indicates: Philco I60: NTC temperature sensor signal out of range (open or short circuit) in Dishwasher..
What is the root cause of Philco error code I60?
The primary root cause for Philco code I60 is: The dishwasher is not heating the water, or has overheated. This could be a faulty heating element, NTC sensor, or a wiring issue..
How do I fix or resolve Philco error code I60?
To resolve error code I60: This error usually requires a technician to test the heating circuit components (element, thermostat, sensor) and replace the faulty part.
Is it safe to clear Philco error code I60 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Philco code I60 persists, the physical component causing The dishwasher is not heating the water, or has overheated. This could be a faulty heating element, NTC sensor, or a wiring issue. must be inspected or replaced.
How do I test electrical resistance for Philco code I60 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Philco code I60?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?