DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure I60
FAQ TREEWhat does error code I60 mean on a Faure appliance?
Faure error code I60 indicates: Faure FDF Series / Clean&Dry / MaxiWash Dishwasher: Water heating general malfunction i60; wash water fails to heat to target temperature within cycle window..
What is the root cause of Faure error code I60?
The primary root cause for Faure code I60 is: On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Flow-through heating element open circuit (nominal 25–28 Ω, ~2000W), tripped Klixon safety thermostat, heating relay contact burnt on PCB, or NTC failure..
How do I fix or resolve Faure error code I60?
To resolve error code I60: Measure resistance across heater element terminals with multimeter (nominal 25–28 Ω). Check continuity of inline thermal fuses (< 1 Ω). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code I60 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code I60 persists, the physical component causing On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Flow-through heating element open circuit (nominal 25–28 Ω, ~2000W), tripped Klixon safety thermostat, heating relay contact burnt on PCB, or NTC failure. must be inspected or replaced.
How do I test electrical resistance for Faure code I60 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Faure code I60?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.