Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Rosieres AL02
FAQ TREEWhat does error code AL02 mean on a Rosieres appliance?
Rosieres error code AL02 indicates: Rosieres AL02: Cooling circuit or defrost system anomaly in Refrigerator / Freezer; compartment temperature deviation..
What is the root cause of Rosieres error code AL02?
The primary root cause for Rosieres code AL02 is: The sensor attached to the evaporator coil (part of the cooling system) is faulty..
How do I fix or resolve Rosieres error code AL02?
To resolve error code AL02: This sensor is involved in the defrost cycle. It will need to be accessed and replaced by a service technician.
Is it safe to clear Rosieres error code AL02 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code AL02 persists, the physical component causing The sensor attached to the evaporator coil (part of the cooling system) is faulty. must be inspected or replaced.
How do I test electrical resistance for Rosieres code AL02 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Rosieres code AL02?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?