Scholtès F16 — Oven
[ACTIVE]Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F16 registered by the microcomputer controller. Touch control optical panel keys locked / persistent contact (>15s)
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: grease or moisture film over touch glass Metrological tolerance verification: nominal PT1000 platinum RTD sensor 1080 Ω at 20°C (1000 Ω at 0°C).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure probe resistance across harness terminals (expected ~1080 Ω at 20°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.