Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Siltal AL02
FAQ TREEWhat does error code AL02 mean on a Siltal appliance?
Siltal error code AL02 indicates: Dishwasher does not fill with water.
What is the root cause of Siltal error code AL02?
The primary root cause for Siltal code AL02 is: Water fill timeout. This is an alternative code for E1 on some models..
How do I fix or resolve Siltal error code AL02?
To resolve error code AL02: Check that the water tap is on. Inspect the inlet hose and filter for blockages. Test the water inlet valve.
Is it safe to clear Siltal error code AL02 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Siltal code AL02 persists, the physical component causing Water fill timeout. This is an alternative code for E1 on some models. must be inspected or replaced.
How do I test electrical resistance for Siltal code AL02 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..
What safety protocol must be followed before servicing Siltal code AL02?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?