OFFICIAL FAULT CODEAL05
Siltal
Siltal // OFFICIAL DIAGNOSTIC BENCH

Siltal AL05

DishwasherDrive Motor, Inverter & Tachometer Sensor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code AL05:CandyAL05SchulthessAL05ArdoAL05NovomaticAL05SangiorgioAL05

Symptom / Description

FAULT

No water circulation, dishes remain dirty

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The main wash pump (circulation motor) is faulty, its capacitor has failed, or it is blocked.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check for obstructions in the wash pump. Test the motor's starting capacitor. Test the motor windings for continuity. Replace the pump/motor assembly if needed.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Siltal Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrive Motor, Inverter & Tachometer SensorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Test Pins & Connections
PROBE (+)
PROBE (-)
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Tolerance & Diagnostic CriteriaBLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol & DC Bus: Wait at least 5 minutes after power cutoff to allow inverter DC bus capacitors (380V DC) to bleed down.
  • !Verify 0V DC across inverter filter capacitors before unplugging motor harness connectors.
  • !Keep hands clear of drive belt and pulleys during any manual rotation tng.
3. Preliminary Mechanical & Visual Checks
  • Slip off drive belt and spin drum/motor shaft by hand to check for roaring or seized ball bearings.
  • For universal motors: verify carbon brushes have at least 10mm remaining length and smooth contact faces.
  • Inspect motor suspension rubber mounts and drive belt tension/groove profile.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Siltal AL05

FAQ TREE
What does error code AL05 mean on a Siltal appliance?

Siltal error code AL05 indicates: No water circulation, dishes remain dirty.

What is the root cause of Siltal error code AL05?

The primary root cause for Siltal code AL05 is: The main wash pump (circulation motor) is faulty, its capacitor has failed, or it is blocked..

How do I fix or resolve Siltal error code AL05?

To resolve error code AL05: Check for obstructions in the wash pump. Test the motor's starting capacitor. Test the motor windings for continuity. Replace the pump/motor assembly if needed.

Is it safe to clear Siltal error code AL05 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Siltal code AL05 persists, the physical component causing The main wash pump (circulation motor) is faulty, its capacitor has failed, or it is blocked. must be inspected or replaced.

How do I test electrical resistance for Siltal code AL05 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test 3-Phase Motor Windings / Tacho Generator / Carbon Brushes across Across phase pins U-V, V-W, U-W on motor harness; across tacho pins. Expected nominal reading is 3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator). Tolerance: BLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho..

What safety protocol must be followed before servicing Siltal code AL05?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // SILTAL

Related Siltal Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

AL06Water Level Pressure Switch & Air Dome
Machine overfills with water
Inspect Protocol
E1Water Inlet Valve, Aquastop & Flowmeter
Dishwasher stops mid-cycle, beeping
Inspect Protocol
E2Drainage System & Drain Pump
Dishwasher cycle finishes with dirty water inside
Inspect Protocol
E3NTC Temperature Sensor & Thermistor
Dishes are not being cleaned with hot water, cycle is cold
Inspect Protocol
E4Drainage System & Drain Pump
Dishwasher has stopped and is continuously trying to drain
Inspect Protocol
E5NTC Temperature Sensor & Thermistor
Cycle is not heating correctly or stops before heating phase
Inspect Protocol
E6NTC Temperature Sensor & Thermistor
Siltal E6: NTC temperature sensor signal out of range (open or short circuit) in Dishwasher.
Inspect Protocol
E7NTC Temperature Sensor & Thermistor
Water overheats or cycle stops unexpectedly
Inspect Protocol
AL01Drainage System & Drain Pump
Machine stops, drain pump may run continuously
Inspect Protocol
AL02Water Inlet Valve, Aquastop & Flowmeter
Dishwasher does not fill with water
Inspect Protocol
AL03Drainage System & Drain Pump
Dishwasher does not drain
Inspect Protocol
E01Door Lock Mechanism & Safety Interlock
Machine won't start, door light flashing
Inspect Protocol
E02Water Inlet Valve, Aquastop & Flowmeter
Machine not filling with water
Inspect Protocol
E03Drainage System & Drain Pump
Machine not draining water, cycle stops with water inside
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy