Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEi30
V-Zug
V-Zug // OFFICIAL DIAGNOSTIC BENCH

V-Zug Dishwasher i30

DishwasherWater Inlet Valve, Aquastop & Flowmeter
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Swiss & Nordic Precision Group: Equivalent Code Across OEM Group Brands
Swiss & Nordic High-Precision Engineering Architecture
Schulthessi30FORSi30Merkeri30
Other Brands Sharing Code i30:ElectroluxI30AEGI30ZanussiI30Arthur MartinI30FAGORI30Schaub LorenzI30AirluxI30AtlanticI30CastorI30

Symptom / Description

FAULT

Anti-flood system activated. Diagnostic error code i30 reported on V-Zug Dishwasher.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On V-Zug Dishwasher: Water has leaked into the base of the dishwasher, tripping the safety float switch.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1On V-Zug Dishwasher: Turn off the water and power to the appliance. The leak source must be identified and repaired by a qualified technician before resetting the system.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide V-Zug Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Water Inlet, Aquastop & Flowmeter Loop

Inlet Solenoid Valve Y1, Reed Turbine Flowmeter & Aquastop Float S2

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III3.84 kΩVΩCOMINLET VALVE Y1SOLENOID Y1: 4.0 kΩFLOWMETER B1 (REED)AQUASTOP SWITCH S2: 0.0Ω
Target Component
Solenoid Valve Coil / Aquastop Pneumatic Valve
Nominal Resistance / Test Range
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)
Test Harness Pins
Across coil spade terminals (disconnect harness first)
Diagnostic Verification Rule
OL on solenoid indicates open coil. Closed contact on float switch S2 indicates base pan leak.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Inlet Valve, Aquastop & FlowmeterDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Solenoid Valve Coil / Aquastop Pneumatic Valve
Test Pins & Connections
PROBE (+)
PROBE (-)
Across coil spade terminals (disconnect harness first)
Tolerance & Diagnostic Criteria±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical power before touching solenoid valve coils or Aquastop connectors.
  • !Firmly shut off the domc water supply tap before unscrewing the inlet hose fitting.
  • !Check safety base drip tray for accumulated water triggering the anti-flood polystyrene float switch.
3. Preliminary Mechanical & Visual Checks
  • Remove and clean sediment and sand particles from the 3/4" inlet hose metal mesh filter.
  • Verify domestic dynamic water pressure is between 1.0 and 10.0 bar (0.1 to 1.0 MPa).
  • Inspect outer Aquastop hose jacket for expansion, pinch damage, or internal leak reservoir triggering.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: V-Zug I30

FAQ TREE
What does error code I30 mean on a V-Zug appliance?

V-Zug error code I30 indicates: Anti-flood system activated. Diagnostic error code i30 reported on V-Zug Dishwasher..

What is the root cause of V-Zug error code I30?

The primary root cause for V-Zug code I30 is: On V-Zug Dishwasher: Water has leaked into the base of the dishwasher, tripping the safety float switch..

How do I fix or resolve V-Zug error code I30?

To resolve error code I30: On V-Zug Dishwasher: Turn off the water and power to the appliance. The leak source must be identified and repaired by a qualified technician before resetting the system.

Is it safe to clear V-Zug error code I30 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if V-Zug code I30 persists, the physical component causing On V-Zug Dishwasher: Water has leaked into the base of the dishwasher, tripping the safety float switch. must be inspected or replaced.

How do I test electrical resistance for V-Zug code I30 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..

What safety protocol must be followed before servicing V-Zug code I30?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // V-ZUG

Related V-Zug Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

i50Dishwasher
Drive Motor, Inverter & Tachometer Sensor
Wash pump or circulation pump fault. Diagnostic error code i50 reported on V-Zug Dishwasher.
Inspect Protocol
i60Dishwasher
NTC Temperature Sensor & Thermistor
V-Zug I60: NTC temperature sensor signal out of range (open or short circuit) in Dishwasher.
Inspect Protocol
iC0Dishwasher
Electronic Control Board (PCB) & Bus Communications
V-Zug IC0: Operational cycle fault detected during Dishwasher program execution.
Inspect Protocol
C1Dishwasher
General System & Mechanical Integration
V-Zug C1: Operational cycle fault detected during Dishwasher program execution.
Inspect Protocol
E01Dishwasher
Water Level Pressure Switch & Air Dome
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Water fill timeout E01; su...
Inspect Protocol
E02Dishwasher
Drainage System & Drain Pump
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Waste water draining fault...
Inspect Protocol
E03Dishwasher
NTC Temperature Sensor & Thermistor
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Water heating failure E03;...
Inspect Protocol
E04Dishwasher
Drainage System & Drain Pump
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Base pan leak detection E0...
Inspect Protocol
E05Dishwasher
NTC Temperature Sensor & Thermistor
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Temperature sensor communi...
Inspect Protocol
E06Dishwasher
Drive Motor, Inverter & Tachometer Sensor
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Circulation pump motor sta...
Inspect Protocol
E07Dishwasher
Drive Motor, Inverter & Tachometer Sensor
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Spray diverter positioning...
Inspect Protocol
E08Dishwasher
Water Inlet Valve, Aquastop & Flowmeter
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Water softener circuit fau...
Inspect Protocol
E09Dishwasher
Door Lock Mechanism & Safety Interlock
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: AquaSensor turbidity calib...
Inspect Protocol
E10Dishwasher
Door Lock Mechanism & Safety Interlock
V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Appliance configuration er...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy