Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
Brandt • Central Diagnostic Dictionary
136 Verified Codes in Database

Brandt Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Brandt appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum

Brandt — Complete OEM Fault Code Matrix & Reference Table

Official diagnostic reference matrix of Brandt error codes, symptom descriptions, and verified technical inspection points.

136 / 136 results
Official diagnostic reference matrix of Brandt error codes, symptom descriptions, and verified technical inspection points.
CodeAppliancesSymptom / Fault DescriptionPrimary Component / Test PointAction
A1Hob

Brandt Induction Hob displays 'A1' on the cooking zone digital readout and ceases heating the cookware.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
A2Hob

Brandt Induction Hob flashes 'A2' across touch control sliders and refuses to activate any cooking zones.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
AL01Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: High temperature alarm in freezer compartment AL01; internal temperature rises above -9°C and audible buzzer sounds.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
AL02Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Door open warning signal persistent AL02; acoustic door alarm sounds and interior light remains energized with door shut.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
ASHob

Brandt BPI / BTI MaxiZone Induction Cooktop: Auto-Stop safety timeout triggered AS; all induction cooking zones shut down automatically after liquid spillover or prolonged cooking.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
CFWashing Machine

Brandt Malice Top-loading Washer halts mid-cycle and displays 'CF' with flashing Posistop drum light.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d01Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Water fill timeout d01; appliance fails to fill with adequate water volume within 4 minutes of program launch.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d01Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Condensation water reservoir full d01; dryer halts cycle and triggers acoustic water tank warning.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d01Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Fridge compartment temperature sensor failure d01; internal cold air temperature fluctuates uncontrollably.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d01Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Water intake timeout d01; tub water level does not reach wash threshold within 6 minutes of valve opening.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
d02Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Drain pump timeout d02; dirty wash water remains pooled in the sump tub after 3 minutes of pumpout.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d02Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Condensate lift pump failure d02; water fails to pump up into collection tank and accumulates in chassis sump base.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d02Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Freezer evaporator defrost sensor error d02; automatic defrost termination fails causing frost build-up.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d02Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Drain pump timeout d02; water remains in the drum after 4 minutes of continuous drain pump operation.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d03Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Wash heating system failure d03; water remains unheated during wash cycles and dishes exit wet and unwashed.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d03Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Process air heating circuit fault d03; tumble dryer rotates cold air and clothes remain damp after prolonged running.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
d03Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Ambient room temperature sensor error d03; unit cannot adapt cooling cycles to room climate variations.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d03Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Heating circuit timeout d03; water temperature fails to increase by more than 2°C within 30 minutes of wash cycle.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
d04Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Sump NTC temperature thermistor fault d04; temperature readings deviate outside 0°C to 85°C operating parameters.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d04Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Drum motor drive stall d04; drive motor hums loudly or fails to turn the drum loaded with damp laundry.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d04Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Defrost heating element or thermal fuse circuit fault d04; evaporator coil blocked with solid ice, stopping airflow.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d04Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Motor drive electronic fault d04; drum spins at uncontrollable high speed immediately upon cycle start.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d05Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Wash circulation pump stall d05; main wash motor hums but fails to rotate spray arms and wash dishes.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d05Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Front exhaust air NTC thermistor fault d05; controller registers out-of-bounds temperature signal on lint filter duct.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d05Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Evaporator circulation fan motor failure d05; cold air does not circulate into the refrigeration compartments.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d05Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Wash NTC temperature sensor fault d05; microcomputer detects out-of-range sensor readings (< -10°C or > 105°C).

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d06Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Wash motor overcurrent cutoff d06; power electronic controller trips due to excessive electric current draw by the circulation pump.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d06Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Rear heating duct NTC thermistor fault d06; heater bank inlet temperature measurement is erratic or open.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d06Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Motorized air damper flap malfunction d06; fresh food compartment either freezes contents or remains too warm.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d06Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Motor tachometer signal fault d06; drum does not rotate or motor starts then immediately stops after speed feedback loss.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d07Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: AquaSafe anti-flood base pan float triggered d07; machine halts wash cycle and forces continuous drain pumpout.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d07Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Air circulation restriction detected d07; airflow differential pressure drops significantly across condenser heat exchanger.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d07Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Condenser cooling fan motor failure d07; compressor overheats, trips overload protector, and cooling stops.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d07Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Door interlock safety fault d07; cycle will not begin because electronic module cannot confirm closed door contact.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
d08Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Alternating spray distributor valve motor fault d08; wash water does not alternate between upper and lower spray arms.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d08Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Electronic moisture sensing fault d08; conductivity sensors detect zero resistance or short-circuit across drum paddles.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d08Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Inverter compressor drive or communication failure d08; compressor fails to start or rapidly cuts out after clicking.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d08Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Drum rotation reversal fault d08; drum rotates only in one direction during wash tumble phases.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
d09Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Internal control bus communication error d09; display fascia loses synchronism with main hydraulic power board.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d09Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Electronic control EEPROM checksum error d09; program options corrupt or cycle parameters fail digital verification.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
d09Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Automatic ice maker mechanism failure d09; ice cubes are not ejected into storage bucket or water fill fails.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d09Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Program selector encoder fault d09; control module receives conflicting or erratic program selection binary code.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
d10Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Continuous uncontrolled water fill d10; water continues entering appliance after target fill level is achieved.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
d10Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Heat pump compressor start failure d10; refrigeration compressor fails to pressurize thermodynamic circuit during drying.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
d10Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Main electronic control PCB memory error d10; unit resets intermittently or fails to execute temperature programs.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
d10Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Overflow safety level reached d10; machine forces emergency drain pump operation to prevent flood.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
d11Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Pressure switch chamber clogged d11; water column sensing membrane is sluggish or fails to return to zero.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
d11Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Heat pump evaporator NTC thermistor fault d11; low-temperature thermodynamic evaporator sensor reading is open or aberrant.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d11Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Abnormal heating in rinse cycle d11; water heats unexpectedly during cold water rinse phases.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
d12Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Dynamic water level loss d12; water level drops excessively once wash circulation pump starts spraying.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
d12Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Heat pump condenser NTC thermistor fault d12; high-pressure refrigerant condenser temperature sensor signal is out of bounds.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d12Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Residual water detected after pumpout d12; pressure sensor fails to register empty tub state after drain sequence.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
d13Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Water temperature overheating cutoff d13; sump temperature exceeds 75°C safety threshold during cycle.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d13Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Drum drive belt broken or tensioner open d13; motor spins freely but drum does not rotate.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d13Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Spin unbalance cutoff d13; drum spin ramp is terminated repeatedly due to uneven laundry mass distribution.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d14Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Wash pump cavitation / water fill discrepancy d14; circulation motor draws irregular current due to aerated water foam.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
d14Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: High-limit thermal safety thermostat tripped d14; heater element deactivated immediately upon cycle initiation.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
d14Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Detergent dispenser cam error d14; motorized water distributor mechanism fails to index correct product compartment.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d15Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Inverter drum motor communication loss d15; variable speed motor controller fails to respond to main microprocessor commands.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d15Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Electronic pressure switch frequency fault d15; analog level sensor outputs erratic frequency signal to main PCB.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
d16Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Door latch open during cycle d16; cycle pauses immediately as door contact microswitch opens during active operation.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
d16Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Inverter module bus link error d16; main controller loses communication with 3-phase BLDC motor inverter card.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d17Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Top-loading dryer drum positioning fault d17; drum doors fail to orient toward top opening when cycle completes.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d17Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Posistop top-loader drum positioning error d17; drum doors fail to halt facing upward at cycle finish.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d18Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Maximum drying cycle timeout exceeded d18; machine aborts after running for over 180 minutes without reaching target dry state.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d18Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Mains supply frequency out of bounds d18; line frequency deviates outside 47 Hz – 63 Hz operational tolerances.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d19Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: Electrical mains frequency error d19; line frequency fluctuates outside the valid 50 Hz / 60 Hz operating window.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d19Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Inverter module heatsink overtemperature d19; motor drive heat sink temperature exceeds 95°C during active wash cycle.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d20Tumble Dryer

Brandt Malice / Condensation & Heat Pump Tumble Dryer: User interface display communication timeout d20; display panel loses serial synchronization with main power controller.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
d20Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Water distributor stepper motor fault d20; water stream cannot be directed to the selected additive compartment.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d21Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Display to power board communication loss d21; control panel lights flash or display is completely blank while machine halts.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
d22Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Washer-dryer drying heating circuit fault d22; air heating duct fails to reach target temperature during drying cycle.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
d23Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Condenser drying NTC thermistor fault d23; temperature sensing on the condensation duct fails verification.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
d24Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Washer-dryer ventilation fan failure d24; process air blower fails to spin during drying phase.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d25Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Repetitive unbalance abort d25; machine terminates program before final spin after 15 unsuccessful redistribution attempts.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d26Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: BLDC motor inverter overcurrent fault d26; peak motor phase current exceeds safe hardware protection threshold.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d27Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Door unlock timeout at cycle completion d27; door remains securely locked after wash program finishes and drum stops.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E0Refrigerator

Brandt Spazio Refrigerator shows 'E0' on door panel and emits acoustic chime, disabling temperature adjustments.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E1Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Touch control panel link failure E1; induction zones flash 'E1' and power sliders do not respond to fingertip touch.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E2Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Induction coil temperature sensor fault E2; zone display flashes 'E2' and cuts power to prevent glass overheating.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E3Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Mains overvoltage protection trip E3; cooktop disables high-power induction generators when voltage exceeds 265 V RMS.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E4Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Mains undervoltage protection trip E4; cooktop shuts down zones because electrical line voltage drops below 180 V RMS.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E5Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Power generator heatsink overtemperature E5; cooktop throttles or halts cooking because aluminum heatsink exceeds 95°C.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E6Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Induction power board inverter stage failure E6; breaker trips or error E6 displays when attempting to energize zones.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E7Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Electronics cooling fan motor failure E7; cooktop detects stalled or disconnected fan motor during boot diagnostics.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E8Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Pan detection resonant circuit fault E8; zone display flashes 'E8' and fails to acknowledge presence of magnetic cookware.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E9Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Microcontroller configuration jumper / EEPROM mismatch E9; power board variant coding does not match user interface.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E40Washing Machine

Brandt Intellect Washing Machine displays 'E40' and cycle will not start; door lock solenoid fails to latch.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er00Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Electronic programmer time clock error Er00; display flashes '00:00' or error code and refuses to begin heating mode.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er01Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Cavity temperature probe circuit open or shorted Er01; oven immediately halts cooking and beeps continuously.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er02Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Cavity high-temperature limit exceeded Er02; oven safety system triggers after cavity exceeds 320°C in non-pyrolytic baking mode.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
Er03Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Tangential cooling fan motor tachometer fault Er03; oven aborts heating cycle because cabinet cooling airflow cannot be verified.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
Er04Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Pyrolytic door lock mechanism timeout Er04; motorized latch fails to lock the oven door when initiating self-clean mode.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
Er05Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Pyrolytic door unlock failure Er05; oven door remains locked after pyrolytic cleaning completes and cavity cools below 280°C.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
Er06Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Main power board communication timeout Er06; display module loses digital data exchange with the internal power relay board.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
Er07Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: EEPROM memory configuration error Er07; oven parameters fail boot verification and controls freeze.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
Er08Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Meat probe temperature sensor fault Er08; core food probe reads short-circuit or abnormal value when plugged into internal socket.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er09Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Combi-steam boiler generator fault Er09; steam generator dry-boil thermal protection or NTC thermistor error detected.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er10Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Steam boiler water evacuation fault Er10; drain pump fails to pump residual water out of the steam boiler.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
Er11Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Upper heating grill element relay fault Er11; top grill element glows red continuously without cooking program active.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
Er12Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Lower heating sole element relay fault Er12; bottom oven cavity continues heating unchecked regardless of thermostat setting.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
Er13Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Circular convection fan heating element open circuit Er13; convection forced air mode blows air without heating.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
Er14Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Capacitive touch panel continuous keypress error Er14; touch control button registers continuous contact for longer than 10 seconds.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er15Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Electronics housing ambient overtemperature Er15; onboard PCB ambient thermal sensor registers temperatures exceeding 85°C.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F0Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: No cookware detected or unsuitable pan base F0; zone display alternates 'F0' and heating output is withheld.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F01Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Temperature sensor probe open circuit F01; controller senses completely broken cavity temperature sensor loop.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F01Washing Machine

Brandt Intellect / OptiA / Malice Top-Loading Washer: Basque electronic platform water fill fault F01; water inlet solenoid valve fails to supply water within allocated timeout.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
F1Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Water inlet pressure drop error F1; flowmeter impeller does not register incoming pulses during filling phase.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
F1Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: User interface keyboard communication timeout F1; touch control panel loses synchronization with induction power board.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F1Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Defrost evaporator sensor error F1; freezer display blinks warning code and defrost cycle does not terminate properly.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F02Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Temperature sensor probe short circuit F02; controller registers zero resistance on cavity thermal loop.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F2Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Sump water evacuation timeout F2; water remains detected in the bottom sump basin after drain phase timing expires.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
F2Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Induction coil thermal probe circuit anomaly F2; cooking zone halts heating immediately after detecting open or shorted NTC.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F2Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Refrigerator compartment air temperature probe failure F2; display alternates temperature and fault code.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F03Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Tangential cooling fan speed error F03; fan operates at insufficient RPM or tachometer signal is missing.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F3Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Heating system malfunction F3; temperature fails to climb during wash segment, aborting heating cycle.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
F3Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: High voltage surge protection active F3; power board shuts down induction frequency generation to prevent semiconductor destruction.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F3Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Freezer compartment air temperature probe failure F3; freezer temperature control loses precision and warning flashes.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F04Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Pyrolytic door lock motor drive failure F04; latch actuator fails to reach locked position within 60 seconds.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F4Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Sump NTC sensor open or short circuit F4; controller senses disconnected or shorted thermal sensor circuit.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F4Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Generator DC bus undervoltage trip F4; internal filtered rectified voltage collapses under induction pulse load.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F4Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Defrost heater cycle timeout F4; maximum defrost heating duration exceeded without reaching cutout temperature.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F05Oven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Pyrolytic latch microswitch position error F05; position feedback microswitch does not toggle when door unlatches.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F5Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Circulation wash motor electrical fault F5; wash pump fails to run and cycle stalls during wash stages.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
F5Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Induction power stage thermal overload F5; cooling fan cannot dissipate heat quickly enough, triggering thermal power foldback.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F5Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Evaporator fan motor feedback failure F5; fan motor does not achieve target operating RPM during cooling demand.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F6Dishwasher

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Continuous water entry / water level safety fault F6; water continues to rise after program attempts shut-off.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
F6Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Short-circuited IGBT power semiconductor F6; circuit breaker trips with an audible pop when zone is turned on.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F6Refrigerator

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Door display communication fault F6; user interface loses digital connection to the main power board.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F7Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Cooling fan blocked or low RPM stall F7; electronic safety cuts zone power when fan fails to achieve operational speed.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F08Washing Machine

Brandt Washing Machine reports 'F08' during wash phase; water remains cold and program aborts before rinse.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F8Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Continuous pan sensing resonance failure F8; induction coil pulses loudly but cannot sustain stable magnetic field coupling.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F9Hob

Brandt BPI / BTI MaxiZone Induction Cooktop: Control board EEPROM calibration checksum failure F9; factory power table values are corrupted and zones will not operate.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F10Oven

Brandt Built-in Pyrolytic Oven stops during high-temp cooking and flashes 'F10', locking the oven door latch.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F13Washing Machine

Brandt Washing Machine drum makes a brief violent spin jerk then shuts down, displaying fault code 'F13'.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
SAFEOven

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Child safety control lock active SAFE; display shows 'SAFE' and oven controls are locked against accidental activation.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose

Brandt — Known Error Codes

CodeAppliancesFault / DiagnosticsRepair InstructionsAction
Er02
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Cavity high-temperature limit exceeded Er02; oven safety system triggers after cavity exceeds 320°C in non-pyrolytic baking mode.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Welded heating element relay on power PCB feeding current continuously, or drifted PT500 probe.

Cut mains power immediately and let oven cool down. Test heater relay contacts with power disconnected (must be open). Check PT500 resistance. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er03
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Tangential cooling fan motor tachometer fault Er03; oven aborts heating cycle because cabinet cooling airflow cannot be verified.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Jammed cross-flow fan wheel, seized sleeve bearings, disconnected Hall sensor harness, or open fan motor coil (~240–320 Ω).

Spin tangential blower drum by hand to check for mechanical binding. Measure fan motor winding resistance (~240–320 Ω). Check 5V DC Hall sensor signal. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er04
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Pyrolytic door lock mechanism timeout Er04; motorized latch fails to lock the oven door when initiating self-clean mode.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Jammed door latch cam mechanism, broken lock gear motor coil (~4.5–6.0 kΩ), or pitted locking microswitch.

Inspect door lock latch above door cavity. Measure lock motor winding resistance (~4.5–6.0 kΩ). Verify microswitch contacts close (~0 Ω) when locked. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er05
Oven / Microwave
Door Lock Mechanism & Safety Interlock

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Pyrolytic door unlock failure Er05; oven door remains locked after pyrolytic cleaning completes and cavity cools below 280°C.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Deformed door latch hook under thermal stress, stuck unlock microswitch, or PT500 probe falsely reading high.

Allow oven to reach room temperature. Press door inward to relieve mechanical latch friction. Test unlock microswitch contact continuity (~0 Ω). Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er06
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Main power board communication timeout Er06; display module loses digital data exchange with the internal power relay board.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Loosened data ribbon harness, electrical interference spikes, or dropped 12V DC auxiliary supply rail.

Reseat multi-core data harness connecting user interface and relay power PCB. Measure 12V DC and 5V DC supply rails on test pads. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er07
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: EEPROM memory configuration error Er07; oven parameters fail boot verification and controls freeze.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Corrupted non-volatile EEPROM storage sector caused by power grid surge during active baking.

Isolate mains breaker for 15 minutes to force microcomputer memory cold boot. If Er07 persists on power up, replace main control board. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er08
Oven / Microwave
NTC Temperature Sensor & Thermistor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Meat probe temperature sensor fault Er08; core food probe reads short-circuit or abnormal value when plugged into internal socket.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Internal jack socket grease contamination, punctured probe cable insulation, or damaged probe thermistor tip.

Unplug probe. Clean female jack receptacle inside oven with electronics cleaner. Measure resistance across probe plug pins with a multimeter. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er09
Oven / Microwave
NTC Temperature Sensor & Thermistor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Combi-steam boiler generator fault Er09; steam generator dry-boil thermal protection or NTC thermistor error detected.

On Brandt steam combi ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Heavy mineral limescale obstructing boiler heat transfer, open steam heater (~45–60 Ω), or defective boiler NTC (~10 kΩ at 25°C).

Execute automated descaling procedure with commercial sulfamic acid descaler. Measure boiler heating element resistance (~45–60 Ω) and boiler NTC (~10 kΩ at 25°C). Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er10
Oven / Microwave
Drainage System & Drain Pump

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Steam boiler water evacuation fault Er10; drain pump fails to pump residual water out of the steam boiler.

On Brandt steam combi ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Calcium flakes wedging the mini drain pump impeller, blocked silicone drain tube, or open pump coil (~150–220 Ω).

Inspect mini drainage pump below steam generator. Clear scale obstructions from pump chamber. Measure pump coil resistance (~150–220 Ω). Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er11
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Upper heating grill element relay fault Er11; top grill element glows red continuously without cooking program active.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Welded or arced grill power relay contacts on the main power relay circuit board.

Disconnect mains breaker immediately. Measure grill element resistance (~22–26 Ω). Test relay contacts with power off; replace power relay PCB if shorted. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er12
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Lower heating sole element relay fault Er12; bottom oven cavity continues heating unchecked regardless of thermostat setting.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Welded relay contacts on lower bake heating circuit on main power board.

Isolate breaker. Measure bottom bake element resistance (~35–45 Ω). Measure continuity across bake relay contacts with power off (must be open). Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er13
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Circular convection fan heating element open circuit Er13; convection forced air mode blows air without heating.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Burned-out circular calrod heating element surrounding the rear convection fan (~25–32 Ω).

Disconnect power and remove rear internal fan shroud inside oven cavity. Measure resistance across circular element terminals (~25–32 Ω). Replace element. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er14
Oven / Microwave
General System & Mechanical Integration

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Capacitive touch panel continuous keypress error Er14; touch control button registers continuous contact for longer than 10 seconds.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Greasy residue, condensation film over glass front, or detached conductive foam spacer under glass.

Clean front glass panel with a microfiber cloth and glass cleaner. Ensure hands are dry. Power cycle circuit breaker for 60 seconds to recalibrate capacitance. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
Er15
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Electronics housing ambient overtemperature Er15; onboard PCB ambient thermal sensor registers temperatures exceeding 85°C.

On Brandt built-in ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Defective tangential cooling blower, blocked cabinetry ventilation chimney, or damaged upper heat deflector.

Turn off oven and allow cooling. Ensure kitchen cabinet has minimum 50mm rear ventilation gap. Verify tangential cooling fan runs freely. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
F0
Hob / Cooktop
General System & Mechanical Integration

Brandt BPI / BTI MaxiZone Induction Cooktop: No cookware detected or unsuitable pan base F0; zone display alternates 'F0' and heating output is withheld.

On Brandt cooktops utilizing MaxiZone 28cm induction generator, 10-point safety pack, and responsive touch slider controls: Non-ferromagnetic cookware (copper, pure aluminum, ceramic glass), or warped base diameter smaller than 120mm.

Use an induction-compatible pan with a thick flat steel or cast-iron base. Verify with a refrigerator magnet (must stick securely to pan bottom). Wipe glass surface completely dry, power down main circuit breaker for 60 seconds, restore power and press Key Lock sensor for 4 seconds.

Diagnose
F01
Oven / Microwave
NTC Temperature Sensor & Thermistor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Temperature sensor probe open circuit F01; controller senses completely broken cavity temperature sensor loop.

On Brandt ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Broken internal PT500 RTD platinum filament, disconnected connector behind rear insulation, or fractured probe wires.

Unplug oven from power. Measure probe resistance (~540 Ω at 20°C). Inspect sensor wiring behind rear fiberglass blanket. Replace probe if open. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
F01
Washing Machine
Water Inlet Valve, Aquastop & Flowmeter

Brandt Intellect / OptiA / Malice Top-Loading Washer: Basque electronic platform water fill fault F01; water inlet solenoid valve fails to supply water within allocated timeout.

On Brandt washing machines featuring SAV55X chassis with Posistop drum positioning, Flash 30' wash profile, and OptiA 39min cycle logic: Closed external supply tap, clogged inlet hose mesh, or open inlet solenoid coil (~3.8 kΩ).

Verify tap water pressure. Remove and rinse the mesh filter screen at the rear valve inlet. Measure coil resistance (~3.8 kΩ). Turn selector knob to Off, press and hold Start/Pause and Spin Speed keys for 5 seconds until 'd00' or display cleared, then switch on.

Diagnose
F1
Dishwasher
Drainage System & Drain Pump

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Water inlet pressure drop error F1; flowmeter impeller does not register incoming pulses during filling phase.

On Brandt dishwashers featuring Hydrosafe anti-overflow hydraulic circuit, Cyclone wash system, and 44dB acoustic damping: Closed tap, clogged inlet valve screen, stuck flowmeter turbine, or defective reed contact on air break.

Open tap fully. Clean inline filter screen. Measure reed switch pulse closure with a multimeter while water enters air break. Press and hold the Start/Cancel button for 4 seconds until the status LED stops flashing, close door to allow 30s drainage, then power off.

Diagnose
F1
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Brandt BPI / BTI MaxiZone Induction Cooktop: User interface keyboard communication timeout F1; touch control panel loses synchronization with induction power board.

On Brandt cooktops utilizing MaxiZone 28cm induction generator, 10-point safety pack, and responsive touch slider controls: Oxidized ribbon cable pin headers, electrical line transient spikes, or defective 5V DC low-voltage regulator.

Inspect multi-strand cable linking touch panel to power module. Measure 5V DC on logic supply test pads. Reseat connectors firmly. Wipe glass surface completely dry, power down main circuit breaker for 60 seconds, restore power and press Key Lock sensor for 4 seconds.

Diagnose
F1
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Defrost evaporator sensor error F1; freezer display blinks warning code and defrost cycle does not terminate properly.

On Brandt refrigeration units featuring Spazio Total No-Frost multi-channel airflow, fast cooling boost, and dual evaporator electronic management: Fagor Innova platform evaporator NTC sensor out of ohmic range, broken wire harness in cabinet foaming, or plug oxidation.

Measure evaporator NTC resistance at board plug: approx. 10.0 kΩ at 25°C and 32.5 kΩ at 0°C. If value deviates by >15%, replace the probe using service repair kit. Press and hold the Super Cold and Temperature Selection buttons simultaneously for 6 seconds until the acoustic tone confirms memory reset.

Diagnose
F02
Oven / Microwave
NTC Temperature Sensor & Thermistor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Temperature sensor probe short circuit F02; controller registers zero resistance on cavity thermal loop.

On Brandt ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Pinch in braided high-temperature leads, crushed probe sheath touching cavity chassis, or internal short in RTD element.

Disconnect sensor at PCB plug. Measure resistance across pins (must not be zero; nominal ~540 Ω at 20°C). Inspect wiring harness for chassis contact. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
F2
Dishwasher
Drainage System & Drain Pump

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Sump water evacuation timeout F2; water remains detected in the bottom sump basin after drain phase timing expires.

On Brandt dishwashers featuring Hydrosafe anti-overflow hydraulic circuit, Cyclone wash system, and 44dB acoustic damping: Blocked sink spigot connection, debris in drain pump volute, or open drain pump winding (~180–220 Ω).

Check sink drain connector and punch out membrane if newly installed. Measure drain pump motor resistance (~180–220 Ω). Press and hold the Start/Cancel button for 4 seconds until the status LED stops flashing, close door to allow 30s drainage, then power off.

Diagnose
F2
Hob / Cooktop
NTC Temperature Sensor & Thermistor

Brandt BPI / BTI MaxiZone Induction Cooktop: Induction coil thermal probe circuit anomaly F2; cooking zone halts heating immediately after detecting open or shorted NTC.

On Brandt cooktops utilizing MaxiZone 28cm induction generator, 10-point safety pack, and responsive touch slider controls: Fractured coil center thermistor glass bead (~100 kΩ at 25°C), or wire severance under coil mounting disc.

Disconnect coil thermistor plug from power module. Measure resistance across probe leads (~100 kΩ at 25°C). Replace central coil sensor if damaged. Wipe glass surface completely dry, power down main circuit breaker for 60 seconds, restore power and press Key Lock sensor for 4 seconds.

Diagnose
F2
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Refrigerator compartment air temperature probe failure F2; display alternates temperature and fault code.

On Brandt refrigeration units featuring Spazio Total No-Frost multi-channel airflow, fast cooling boost, and dual evaporator electronic management: Open-circuit or short-circuit in the refrigerator compartment NTC thermistor sensor, or disconnected harness.

Check sensor resistance at pins on main PCB: nominal 5.0 kΩ at 25°C and 16.3 kΩ at 0°C. If open or shorted, install service replacement NTC probe. Press and hold the Super Cold and Temperature Selection buttons simultaneously for 6 seconds until the acoustic tone confirms memory reset.

Diagnose
F03
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Tangential cooling fan speed error F03; fan operates at insufficient RPM or tachometer signal is missing.

On Brandt ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Degraded blower motor run winding, dusty fan bearings, or failed Hall sensor IC.

Clean fan roller of lint and dust. Measure motor coil resistance (~240–320 Ω). Verify tachometer signal line voltage (pulses 0–5V DC). Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
F3
Dishwasher
Water Level Pressure Switch & Air Dome

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Heating system malfunction F3; temperature fails to climb during wash segment, aborting heating cycle.

On Brandt dishwashers featuring Hydrosafe anti-overflow hydraulic circuit, Cyclone wash system, and 44dB acoustic damping: Open heater resistance element (~25–28 Ω), blown inline thermal fuse, or open safety pressure switch.

Measure heating element terminals for continuity (~25–28 Ω). Verify safety pressure switch closes when circulation pump creates water pressure. Press and hold the Start/Cancel button for 4 seconds until the status LED stops flashing, close door to allow 30s drainage, then power off.

Diagnose
F3
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Brandt BPI / BTI MaxiZone Induction Cooktop: High voltage surge protection active F3; power board shuts down induction frequency generation to prevent semiconductor destruction.

On Brandt cooktops utilizing MaxiZone 28cm induction generator, 10-point safety pack, and responsive touch slider controls: Lightning strike transient, sudden line inductive load switching, or missing neutral on 400V 3-phase hookup.

Isolate cooktop for 10 minutes. Check supply voltage across all terminals (must be steady 230V AC to Neutral). Ensure neutral is connected solidly. Wipe glass surface completely dry, power down main circuit breaker for 60 seconds, restore power and press Key Lock sensor for 4 seconds.

Diagnose
F3
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Brandt BFL / BFA Spazio Total No-Frost Refrigerator: Freezer compartment air temperature probe failure F3; freezer temperature control loses precision and warning flashes.

On Brandt refrigeration units featuring Spazio Total No-Frost multi-channel airflow, fast cooling boost, and dual evaporator electronic management: Freezer air NTC sensor failure, wire harness pinch at cabinet bottom, or moisture infiltration into sensor body.

Measure freezer sensor resistance: expected approx. 10.0 kΩ at 25°C, 32.5 kΩ at 0°C, and 85 kΩ at -18°C. Replace sensor if resistance does not match temperature curve. Press and hold the Super Cold and Temperature Selection buttons simultaneously for 6 seconds until the acoustic tone confirms memory reset.

Diagnose
F04
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Brandt Soléis / Masterchef / BXP Pyrolytic Built-in Oven: Pyrolytic door lock motor drive failure F04; latch actuator fails to reach locked position within 60 seconds.

On Brandt ovens featuring Soléis Quattro Pulse thermal distribution, Smart Assist guided cooking, and high-density pyrolytic insulation: Open actuator motor coil (~4.8 kΩ), cracked reduction gears, or door hook misalignment.

Check door latch motor coil resistance (~4.8 kΩ). Verify latch mechanism rotates freely without binding against chassis sheet metal. Turn the function dial to 0, isolate the power supply circuit breaker for 60 seconds, restore mains power and set the electronic clock.

Diagnose
F4
Dishwasher
NTC Temperature Sensor & Thermistor

Brandt Hydrosafe / Aquasafe / Silence 44dB Dishwasher: Sump NTC sensor open or short circuit F4; controller senses disconnected or shorted thermal sensor circuit.

On Brandt dishwashers featuring Hydrosafe anti-overflow hydraulic circuit, Cyclone wash system, and 44dB acoustic damping: Defective NTC thermistor element (~47 kΩ at 25°C), disconnected wiring harness, or moisture bridging pins.

Unplug NTC sensor from sump. Measure resistance across probe pins (~47 kΩ at 25°C). Inspect wiring harness for pin push-back. Press and hold the Start/Cancel button for 4 seconds until the status LED stops flashing, close door to allow 30s drainage, then power off.

Diagnose
← Previous PagePage 4 of 5 (136 results)Next Page →

Brandt — Complete Error Code Catalog

136 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Brandt — Dishwasher20

d01d02d03d04d05d06d07d08d09d10d11d12d13d14F1F2F3F4F5F6

Brandt — Washing Machine32

CFd01d02d03d04d05d06d07d08d09d10d11d12d13d14d15d16d17d18d19d20d21d22d23d24d25d26d27E40F01F08F13

Brandt — Tumble Dryer20

d01d02d03d04d05d06d07d08d09d10d11d12d13d14d15d16d17d18d19d20

Brandt — Oven / Microwave23

Er00Er01Er02Er03Er04Er05Er06Er07Er08Er09Er10Er11Er12Er13Er14Er15F01F02F03F04F05F10SAFE

Brandt — Hob / Cooktop22

A1A2ASE1E2E3E4E5E6E7E8E9F0F1F2F3F4F5F6F7F8F9

Brandt — Refrigerator / Freezer19

AL01AL02d01d02d03d04d05d06d07d08d09d10E0F1F2F3F4F5F6

Need Help? Call a Certified Technician

Our official certified partners service Brandt appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy