Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Iberna • Central Diagnostic Dictionary
165 Verified Codes in Database

Iberna Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Iberna appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
E20
Washing Machine
NTC Temperature Sensor & Thermistor

Iberna ILF / EcoTime Pro Inverter Washing Machine: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.

On Iberna washing machines powered by reliable GIAS compact micro-controller, high-efficiency wash group, and fast-response NTC thermistors: Blocked pressure tube, punctured silicone diaphragm, or defective oscillator in electronic pressure switch (~25.6 kHz empty).

Inspect rubber pressure hose for pinholes or splits. Blow through tube towards tub to clear compression dome. Measure sensor output frequency (~25.6 kHz empty). Move program selector to Stop, hold Start/Pause and Spin keys together for 5 seconds until status LEDs extinguish, then restart.

Diagnose
E21
Tumble Dryer
NTC Temperature Sensor & Thermistor

Iberna ITD AirFlow Condenser Tumble Dryer: Moisture sensing calibration amplifier fault E21; analog-to-digital converter receives out-of-scale conductance baseline.

On Iberna tumble dryers utilizing AirFlow condensation duct system, front/rear NTC temperature sensors, and capacitive run motor: Wet conductive fluff bridging sensor strips to chassis, moisture inside front fascia harness, or operational amplifier IC drift.

Thoroughly vacuum lint from sensor bar mounting insulator. Check resistance between sensor strips and chassis (must be infinite >20 MΩ when dry). Set selector to 0, hold Start/Pause and Half Heat buttons for 5 seconds until beep acknowledges memory wipe, then return to Off.

Diagnose
E21
Washing Machine
NTC Temperature Sensor & Thermistor

Iberna ILF / EcoTime Pro Inverter Washing Machine: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.

On Iberna washing machines featuring reliable GIAS compact micro-controller, high-efficiency wash group, and fast-response NTC thermistors: Mechanically weeping solenoid valve diaphragm allowing slow drip, or moisture condensation inside the pressure switch transducer.

Turn off water tap overnight to verify if tub collects water (confirms weeping valve; replace valve). Inspect pressure switch tubing for water droplets. Move program selector to Stop, hold Start/Pause and Spin keys together for 5 seconds until status LEDs extinguish, then restart.

Diagnose
E22
Washing Machine
NTC Temperature Sensor & Thermistor

Iberna ILF / EcoTime Pro Inverter Washing Machine: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.

On Iberna washing machines featuring reliable GIAS compact micro-controller, high-efficiency wash group, and fast-response NTC thermistors: Drain hose installed too low (<65 cm height), drain hose pushed too far into standpipe creating airtight siphon seal.

Ensure top of drain hose bend is suspended between 65 cm and 100 cm above floor level. Use anti-siphon curved elbow and provide air gap in standpipe. Move program selector to Stop, hold Start/Pause and Spin keys together for 5 seconds until status LEDs extinguish, then restart.

Diagnose
EA
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Iberna IR / Total FrostFree Combi Refrigerator: Condenser tube temperature sensor error EA; discharge line thermistor reading indicates abnormal thermal overload.

On Iberna refrigeration units featuring Total FrostFree air circulation evaporator, defrost termination bi-metal, and compressor start relay: Blocked condenser air intake, failed condenser cooling fan, or drifted discharge thermistor resistance.

Clean rear air grilles and condenser mesh. Check condenser NTC sensor resistance (~5 kΩ at 25°C). Ensure minimum 5 cm clearance from rear wall. Reset: Press and hold Fast Freeze button for 8 seconds until warning buzzer stops sounding, confirming internal microprocessor reset.

Diagnose
Ed
Dishwasher
Heating Element, Thermostat & Safety Fuse

Iberna IDI / Standard Wash System Dishwasher: Detergent dispenser actuator fault Ed; tablet door flap fails to trip open during primary wash cycle.

On Iberna dishwashers powered by Standard Wash System hydraulic circuit, solenoid fill valve control, and heating element flow-through tube: Open dispenser wax motor or solenoid actuator coil (~1.5–3.0 kΩ), mechanical latch jam, or broken door wiring.

Remove inner door panel. Measure dispenser actuator coil resistance (~1.5–3.0 kΩ). Check spring-loaded flap latch for smooth movement. Press and hold Start button for 5 seconds until buzzer sounds, close door to allow pump-out cycle to complete, then switch off.

Diagnose
Ed
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Iberna IR / Total FrostFree Combi Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.

On Iberna refrigeration units featuring Total FrostFree air circulation evaporator, defrost termination bi-metal, and compressor start relay: Blown thermal cutoff fuse (72°C/77°C), burned calrod or glass defrost heating element, or stuck defrost relay.

Check defrost heating element resistance (typically 180-280 Ω). Verify continuity across thermal fuse (0 Ω; replace if open). Check 230V AC output from main PCB defrost relay. Reset: Press and hold Fast Freeze button for 8 seconds until warning buzzer stops sounding, confirming internal microprocessor reset.

Diagnose
EF
Dishwasher
Water Level Pressure Switch & Air Dome

Iberna IDI / Standard Wash System Dishwasher: Flowmeter pulse overflow anomaly EF; impulse count exceeds maximum safety tank volume during filling phase.

On Iberna dishwashers featuring Standard Wash System hydraulic circuit, solenoid fill valve control, and heating element flow-through tube: Siphoning water leaking continuously out of drain hose during fill, or defective pressure switch failing to register water depth.

Check drain hose standpipe height (must be between 65 cm and 100 cm). Clear pressure switch dome in sump. Check pressure transducer contacts. Press and hold Start button for 5 seconds until buzzer sounds, close door to allow pump-out cycle to complete, then switch off.

Diagnose
EF
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Iberna IR / Total FrostFree Combi Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.

On Iberna refrigeration units featuring Total FrostFree air circulation evaporator, defrost termination bi-metal, and compressor start relay: Heavy Frost buildup surrounding fan blades, ice intrusion into motor hub, or shorted motor phase winding.

Perform complete 24h manual defrost to clear ice jacket. Verify fan spins freely by hand. Check winding resistance; replace fan if winding shorted. Reset: Press and hold Fast Freeze button for 8 seconds until warning buzzer stops sounding, confirming internal microprocessor reset.

Diagnose
Eh
Dishwasher
NTC Temperature Sensor & Thermistor

Iberna IDI / Standard Wash System Dishwasher: Heating circuit safety thermal overheat Eh; water temperature sensor detects temperature exceeding 85°C.

On Iberna dishwashers utilizing Standard Wash System hydraulic circuit, solenoid fill valve control, and heating element flow-through tube: Welded heating relay contacts on main PCB keeping heater powered continually, or defective NTC sensor.

Disconnect mains immediately. Measure heater relay output voltage with machine in standby (must be 0V AC; if 230V AC present, relay is welded). Press and hold Start button for 5 seconds until buzzer sounds, close door to allow pump-out cycle to complete, then switch off.

Diagnose
EL
Dishwasher
Water Inlet Valve, Aquastop & Flowmeter

Iberna IDI / Standard Wash System Dishwasher: Low incoming water pressure detected EL; flowmeter pulse cadence indicates line pressure under 0.5 bar.

On Iberna dishwashers featuring Standard Wash System hydraulic circuit, solenoid fill valve control, and heating element flow-through tube: Partially open supply stopcock, clogged sediment pre-filter in building plumbing, or shared simultaneous water usage.

Open inlet stopcock fully. Disconnect fill hose and run water into bucket to measure flow rate (minimum 8 liters per minute required). Press and hold Start button for 5 seconds until buzzer sounds, close door to allow pump-out cycle to complete, then switch off.

Diagnose
Er
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Iberna IR / Total FrostFree Combi Refrigerator: Electronic controller EEPROM checksum error Er; microcontroller fails internal data validation checksum on power-up.

On Iberna refrigeration units featuring Total FrostFree air circulation evaporator, defrost termination bi-metal, and compressor start relay: Mains voltage surge or lightning strike spike, electrical storm noise, or degraded non-volatile memory cell.

Disconnect mains plug for 10 minutes to allow DC capacitors to discharge completely. If fault persists on reboot, replace programmed main board. Reset: Press and hold Fast Freeze button for 8 seconds until warning buzzer stops sounding, confirming internal microprocessor reset.

Diagnose
Er01
Oven / Microwave
NTC Temperature Sensor & Thermistor

Iberna IB / Classic Convection & Pyrolytic Oven: Cavity temperature sensor open circuit Er01; electronic controller reads infinite resistance from the PT500 / PT1000 oven probe.

On Iberna ovens utilizing Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Broken platinum resistor probe inside cavity, heat-damaged silicone wiring behind rear insulation, or loose PCB terminal.

Isolate power at breaker. Disconnect sensor plug at rear. Measure probe resistance (~538 Ω for PT500 or ~1078 Ω for PT1000 at 20°C). Replace if infinite. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er02
Oven / Microwave
NTC Temperature Sensor & Thermistor

Iberna IB / Classic Convection & Pyrolytic Oven: Cavity temperature sensor short circuit Er02; measured resistance across probe terminals drops below 100 Ω threshold.

On Iberna ovens powered by Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Pinching of probe lead wires by rear metal backplate screws, crushed fiberglass sleeving, or internal short in sensing bulb.

Inspect wiring harness from probe to PCB for pinched insulation. Verify probe resistance disconnected from PCB (nominal ~538 Ω / ~1078 Ω at 20°C). Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er03
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.

On Iberna ovens featuring Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Welded heating element relay contacts on power board keeping elements energized continuously, or defective probe.

Disconnect power breaker immediately. Allow oven to cool down completely. Test heating element relay contacts on power PCB for short circuit. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
ER03
Hob / Cooktop
General System & Mechanical Integration

Iberna IH Touch Induction & Radiant Cooktop: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls.

On Iberna cooktops utilizing IH Touch induction power converters, radiant coil zones, and touch-sensitive key lockout: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone.

Remove all pots and utensils from glass. Sponge up all liquids and dry touch area thoroughly with a clean microfiber cloth. Clear moisture from control area, power down circuit breaker for 40 seconds, restore power and touch Lock Key for 5 seconds.

Diagnose
Er04
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Tangential cooling fan failure Er04; electronics cooling blower tachometer signal absent or speed falls below minimum RPM.

On Iberna ovens utilizing Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Jammed cross-flow fan impeller, open fan motor winding (~180–350 Ω), or defective Hall effect tachometer sensor.

Inspect tangential fan above cavity for free spin. Measure fan motor coil resistance (~180–350 Ω across terminals). Check Hall sensor 5V DC supply. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er05
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.

On Iberna ovens powered by Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Misaligned door catch hook, open synchronous latch motor coil (~2.0–4.5 kΩ), or defective lock microswitch.

Check door alignment and latch hook entry. Measure door lock synchronous motor resistance (~2.0–4.5 kΩ). Verify cam microswitch continuity when latched. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er06
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Pyrolysis door unlock timeout Er06; motorized latch mechanism fails to retract after cavity cools below safe temperature (~250°C).

On Iberna ovens utilizing Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Jammed mechanical cam linkage, defective unlock feedback switch, or power failure during unlock stroke.

Confirm cavity has fully cooled to room temperature. Manually actuate unlock cam mechanism from upper service access. Replace latch motor assembly. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er07
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Food meat probe circuit fault Er07; internal core thermometer probe reads short-circuited or out-of-scale temperature.

On Iberna ovens featuring Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Liquid grease ingress inside meat probe jack socket on cavity wall, punctured probe silicone cord, or shorted connector.

Unplug meat probe from wall jack. Clean socket contact pins with isopropyl alcohol. Measure probe resistance with multimeter (~10 kΩ or ~1000 Ω depending on type). Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er08
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.

On Iberna ovens utilizing Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Disconnected or heat-damaged communication ribbon cable, power board transformer failure, or lost 12V DC rail.

Inspect multi-conductor cable connecting display to rear relay board. Reseat connectors and verify 12V DC and 5V DC power rails with voltmeter. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er09
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Stuck touch control key error Er09; capacitive glass touch pad detects continuous activation for longer than 30 seconds.

On Iberna ovens powered by Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Grease film, liquid spillage, metal pot handle resting against touch glass, or damaged capacitive sensing spring.

Clean and dry the entire glass control fascia with microfiber cloth and glass cleaner. Ensure no objects touch glass. Power cycle breaker if persists. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er15
Oven / Microwave
NTC Temperature Sensor & Thermistor

Iberna IB / Classic Convection & Pyrolytic Oven: Electronics housing ambient overtemperature Er15; control board internal thermal sensor detects temperature exceeding 85°C.

On Iberna ovens utilizing Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Failed cooling fan motor, blocked cabinetry ventilation slots, or thermal insulation blanket compression.

Verify cooling fan operates during bake cycle. Ensure cabinet has minimum 50 mm rear air ventilation gap. Check board NTC sensor calibration. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
Er20
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Microcontroller flash memory checksum fault Er20; internal processor ROM memory block verification fails at boot.

On Iberna ovens powered by Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Mains power surge damage to microcontroller flash sector, electrical line noise, or incomplete firmware programming.

Power down at breaker for 15 minutes to clear RAM. If error reoccurs upon power restoration, main control module requires replacement. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
ER20
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Iberna IH Touch Induction & Radiant Cooktop: Microcontroller flash / EEPROM checksum error ER20; induction power board parameter registers corrupted.

On Iberna cooktops featuring IH Touch induction power converters, radiant coil zones, and touch-sensitive key lockout: High-voltage inductive spike from cooking zone switching, mains supply transient, or memory cell fatigue.

Power off cooker circuit breaker for 10 minutes to reset microcomputer registers. If error persists on power up, replace induction power board. Clear moisture from control area, power down circuit breaker for 40 seconds, restore power and touch Lock Key for 5 seconds.

Diagnose
Er21
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.

On Iberna ovens utilizing Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Dried electrolytic filter capacitors on switch-mode power supply, shorted optocoupler, or excessive relay coil current draw.

Measure DC voltages across power supply test points with multimeter (must read clean 5.0V DC and 12.0V DC without AC ripple). Replace power board if low. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
ER21
Hob / Cooktop
General System & Mechanical Integration

Iberna IH Touch Induction & Radiant Cooktop: Ambient electronics housing temperature exceeded ER21; internal temperature inside cooktop enclosure exceeds 85°C.

On Iberna cooktops powered by IH Touch induction power converters, radiant coil zones, and touch-sensitive key lockout: Blocked cabinetry ventilation intake/exhaust, pyrolytic oven installed underneath running a self-clean cycle, or failed cooling fan.

Turn off all cooking zones and allow 20 minutes to cool. Verify cabinetry ventilation slots are unobstructed. Check cooling fan rotation. Clear moisture from control area, power down circuit breaker for 40 seconds, restore power and touch Lock Key for 5 seconds.

Diagnose
Er22
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Touch control panel matrix evaluation error Er22; touch controller detects invalid internal scanning line pattern.

On Iberna ovens featuring Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Moisture condensation between glass panel and touch PCB, mechanical displacement of touch springs, or controller IC defect.

Dismantle fascia panel and clean/dry glass inner surface. Ensure all conductive spring contacts sit centered on designated capacitive pad zones. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
ER22
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Iberna IH Touch Induction & Radiant Cooktop: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.

On Iberna cooktops utilizing IH Touch induction power converters, radiant coil zones, and touch-sensitive key lockout: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage.

Open hob housing. Inspect touch sensor PCB for liquid stains or corrosion. Clean contacts with isopropyl alcohol. Replace touch PCB if hardware damaged. Clear moisture from control area, power down circuit breaker for 40 seconds, restore power and touch Lock Key for 5 seconds.

Diagnose
Er31
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Iberna IB / Classic Convection & Pyrolytic Oven: Appliance variant model configuration error Er31; EEPROM parameters do not match installed hardware options (rotisserie, pyro, steam).

On Iberna ovens utilizing Classic convection heating elements, rotary thermostat regulation, and tangential cooling airflow: Unprogrammed replacement PCB installed, incorrect service code entered during board replacement, or memory corruption.

Enter factory diagnostic mode and input the 16-digit variant configuration code from the oven side rating label. Confirm and store settings. Turn thermostat and selector dials to 0, switch off main breaker for 60 seconds, restore circuit and set clock time.

Diagnose
← Previous PagePage 4 of 6 (165 results)Next Page →

Iberna — Complete Error Code Catalog

77 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher30

AL03AL05E01E1E02E2E03E3E04E4E05E5E06E6E07E7E08E8E9E10E12E14E15E16E17E18EdEFEhEL

Washing Machine8

CLrE20E22FAFC0FC1FC2Unb

Tumble Dryer10

E09E11E13E21F1F2F3F4F5F6

Oven / Microwave19

Er01Er02Er03Er04Er05Er06Er07Er08Er09Er15Er20Er21Er22Er31Er36Er47Er56LocSabb

Hob / Cooktop6

E0F0F7F8F9U

Refrigerator / Freezer4

AL01AL02EAEr

Need Help? Call a Certified Technician

Our official certified partners service Iberna appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy