Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code Door Alarm registered by the microcomputer controller. Door left open optical and acoustic warning tone active >60 seconds
Compressor Motor Windings (Run/Start) & Defrost Heater
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code E0 registered by the microcomputer controller. Communication loss between door display and base power module
Compressor Motor Windings (Run/Start) & Defrost Heater
Liebherr Gourmet Built-in Convection Oven: Diagnostic fault code E4 registered by the microcomputer controller. Liebherr: Communication error between user interface and power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Liebherr Gourmet Built-in Convection Oven: Diagnostic fault code E8 registered by the microcomputer controller. Liebherr E8: Motor drive or inverter rotation anomaly in Oven / Microwave; drum/motor fails to spin at target RPM.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Liebherr Gourmet Built-in Convection Oven: Diagnostic fault code E9 registered by the microcomputer controller. Liebherr E9: NTC temperature sensor signal out of range (open or short circuit) in Oven / Microwave.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code E14 registered by the microcomputer controller. Mains power frequency out of 50 Hz ± 3 Hz tolerance range
Compressor Motor Windings (Run/Start) & Defrost Heater
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F3 registered by the microcomputer controller. Freezer interior air temperature measurement out of specification
Compressor Motor Windings (Run/Start) & Defrost Heater
Liebherr Premium AquaStop Integrated Dishwasher: Diagnostic fault code F11 registered by the microcomputer controller. Liebherr F11: Water drainage failure detected in Dishwasher; drain pump cannot evacuate water within safety time limit.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code SN registered by the microcomputer controller. Internal serial network bus communication timeout between boards
Compressor Motor Windings (Run/Start) & Defrost Heater
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F21 registered by the microcomputer controller. BluPerformance plinth condenser cooling fan motor BLDC speed error
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: base fan stalled by dust buildup Metrological tolerance verification: 12V DC supply; tachometer pulses present..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: clear plinth lint screen and verify fan speed telemetry. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F22 registered by the microcomputer controller. BioFresh-Plus variable aperture air baffle stepper motor error
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: stepper motor drive gear jammed Metrological tolerance verification: phase coil resistance ~250 Ω per phase..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure stepper phase windings and test mechanical baffle travel. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F23 registered by the microcomputer controller. Evaporator defrost heating element open circuit
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: defrost heater element wire broken Metrological tolerance verification: nominal 230 Ω ± 7% (230W / 230V)..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure defrost heater resistance across terminals (expected ~230 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: thermal fuse opened at 84°C due to defrost overheat Metrological tolerance verification: continuity 0.0 Ω normal, infinite Ω blown..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: replace inline thermal fuse assembly and inspect defrost thermostat. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F25 registered by the microcomputer controller. Condensate evaporation drain pan heating element open circuit
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: drain pan heater wire broken Metrological tolerance verification: nominal 750 Ω to 850 Ω (65W / 230V)..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across drain pan heater element leads. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F26 registered by the microcomputer controller. Dual-circuit bistable pulse magnetic refrigerant diverter valve error
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: valve solenoid coil open or spool valve stuck Metrological tolerance verification: bistable coil resistance ~1.8 kΩ to 2.2 kΩ..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure valve coil resistance and test pulse switching with magnet. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: IGBT bridge shorted or inverter gate driver destroyed Metrological tolerance verification: DC bus voltage 310V DC; motor winding balanced 9.5-14.5 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test compressor windings across U-V-W and check inverter output. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F28 registered by the microcomputer controller. Compressor motor three-phase windings phase resistance imbalance
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: compressor stator winding inter-turn short circuit Metrological tolerance verification: resistance 9.5 Ω to 14.5 Ω balanced across U-V, V-W, W-U..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance between all three compressor pins; must be identical within 0.3 Ω. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F29 registered by the microcomputer controller. SmartDeviceBox 2.4 GHz wireless communication module offline
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: WLAN module unseated or USB interface communication timeout Metrological tolerance verification: 5V DC USB supply rail present..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: reseat SmartDeviceBox module in slot and verify 5V power. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code F30 registered by the microcomputer controller. Main control PCB microprocessor hardware watchdog reset trigger
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: microcontroller software crash or electrical surge disturbance Metrological tolerance verification: reset line 5V DC stable..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect power board filter capacitors and verify mains ground integrity. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
On Liebherr appliances engineered with Liebherr electronic wash management, flow-through heater, and AquaSafe leak protection: The control board has detected a fault with the pressure switch (level sensor), which may be stuck on or off. Metrological tolerance verification: pressure switch contacts 0.0 Ω closed; trip threshold 35 mbar (350 mm WC).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect pressure dome for blockages and test switch continuity (0.0 Ω closed). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn off unit. Hold Start/Pause while turning on power switch, release after 4 seconds, then press Start/Pause 3 times to enter service reset mode.
Liebherr Premium AquaStop Integrated Dishwasher: Diagnostic fault code F52 registered by the microcomputer controller. Dishwasher heating element fault.. Liebherr Premium AquaStop Integrated Dishwasher: Diagnostic fault code F52 reported by internal controller.
On Liebherr appliances engineered with Liebherr electronic wash management, flow-through heater, and AquaSafe leak protection: The water is not heating. The heating element is faulty, or the relay on the control board has failed. Metrological tolerance verification: tubular heating element resistance nominal 26.5 Ω to 28.5 Ω (2000W / 230V AC).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across heating element terminals (expected ~27.5 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn off unit. Hold Start/Pause while turning on power switch, release after 4 seconds, then press Start/Pause 3 times to enter service reset mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code Fb registered by the microcomputer controller. BioFresh motorized air flap damper servo motor stall
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: damper gear teeth stripped or limit microswitch open Metrological tolerance verification: stepper motor coil resistance ~250 Ω per phase..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test damper motor phase coils and verify free mechanical flap movement. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code Fc registered by the microcomputer controller. Condenser coil critical high temperature safety cutoff
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: condenser temperature exceeded 75°C due to clogged ventilation Metrological tolerance verification: thermal sensor resistance < 900 Ω indicates high heat..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: vacuum base plinth condenser matrix and verify condenser fan operation. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code Fd registered by the microcomputer controller. NoFrost evaporator defrost heating cycle exceeded maximum safety time
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: defrost heater failed to clear evaporator within 70 minutes Metrological tolerance verification: defrost heater element nominal 230 Ω ± 7% (230W / 230V)..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure defrost heater resistance (expected ~230 Ω) and thermal fuse continuity. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code FE registered by the microcomputer controller. Electronic IceMaker microprocessor communication timeout
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: IceMaker internal control PCB unresponsive on serial line Metrological tolerance verification: bidirectional UART data link at 5V logic level..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: verify wiring harness across door hinge and check IceMaker 12V DC supply. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code FF registered by the microcomputer controller. Freezer evaporator fan motor stalled or power supply disconnected
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: fan blade blocked by ice accumulation Metrological tolerance verification: fan motor coil ~45 Ω or 12V BLDC driver..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: defrost evaporator housing and verify 12V DC power to fan motor. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code FO registered by the microcomputer controller. BluPerformance base air intake ambient thermistor fault
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: plinth intake air temperature NTC probe open circuit Metrological tolerance verification: nominal 4.7 kΩ at 25°C..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure base sensor resistance across terminals at power board. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: refrigerant charge low, capillary restriction, or compressor weak Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: wine cellar air filter timer elapsed Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Electronic Control Board (PCB) & Bus Communications
Liebherr Touch-Control Induction Hob: Diagnostic fault code L1 registered by the microcomputer controller. Induction hob power board fault.. Liebherr Touch-Control Induction Hob: Diagnostic fault code L1 reported by internal controller.
On Liebherr appliances engineered with Liebherr high-efficiency planar inductors and dual micro-fan heatsink cooling: Error on the left side power module of the induction hob. Metrological tolerance verification: microcontroller regulated logic rail 5.0V DC ± 0.1V; I2C/SPI bus clock 100 kHz.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure stabilized 5.0V DC logic supply voltage at test points on main PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: De-energize circuit breaker for 3 minutes. Power on, touch Key-lock key for 4 seconds, then slide zone 1 slider from 0 to 9 twice.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code NA registered by the microcomputer controller. Power cut occurred during absence; display indicates warmest temp reached
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: mains power interrupted during operation Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code PF registered by the microcomputer controller. Mains electricity interrupted; controller resumed on default profile
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: mains brownout or brief power failure Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Electronic Control Board (PCB) & Bus Communications
Liebherr Touch-Control Induction Hob: Diagnostic fault code R1 registered by the microcomputer controller. Induction hob power board fault.. Liebherr Touch-Control Induction Hob: Diagnostic fault code R1 reported by internal controller.
On Liebherr appliances engineered with Liebherr high-efficiency planar inductors and dual micro-fan heatsink cooling: Error on the right side power module of the induction hob. Metrological tolerance verification: microcontroller regulated logic rail 5.0V DC ± 0.1V; I2C/SPI bus clock 100 kHz.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure stabilized 5.0V DC logic supply voltage at test points on main PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: De-energize circuit breaker for 3 minutes. Power on, touch Key-lock key for 4 seconds, then slide zone 1 slider from 0 to 9 twice.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code SN registered by the microcomputer controller. Internal serial network bus communication timeout between boards
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: RS-485 / LIN bus cable disconnected Metrological tolerance verification: differential bus voltage 2.5V-3.5V DC..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect wiring harnesses connecting display, power board, and inverter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Electronic Control Board (PCB) & Bus Communications
Liebherr Touch-Control Induction Hob: Diagnostic fault code T1 registered by the microcomputer controller. Touch control panel error.. Liebherr Touch-Control Induction Hob: Diagnostic fault code T1 reported by internal controller.
On Liebherr appliances engineered with Liebherr high-efficiency planar inductors and dual micro-fan heatsink cooling: A button on the touch panel is stuck, or the panel has a general malfunction. Metrological tolerance verification: capacitive surface impedance < 50 Ω due to conductive film; logic rail 5.0V DC.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure stabilized 5.0V DC logic supply and verify track isolation > 20 MΩ when dry. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: De-energize circuit breaker for 3 minutes. Power on, touch Key-lock key for 4 seconds, then slide zone 1 slider from 0 to 9 twice.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code T7 registered by the microcomputer controller. Wine cellar circulating air ventilation fan motor failure
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: internal air circulation fan stalled Metrological tolerance verification: fan motor coil resistance ~180 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check fan blade for obstruction and test 230V AC supply to fan motor. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code Filter Symbol registered by the microcomputer controller. Internal water purification cartridge lifespan expired (6 months / 750L)
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: water filter timer elapsed Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: demo mode enabled in service menu Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.
Liebherr BioFresh / BluPerformance / Monolith / NoFrost Premium Refrigerator & Wine Cellar: Diagnostic fault code Flashing minus sign registered by the microcomputer controller. Display shows flashing minus sign: freezer temperature warmer than 0°C
On Liebherr appliances engineered with BioFresh climate chambers, BluPerformance base refrigeration module, DuoCooling dual refrigerant circuits, and VCC inverter compressor with 4.7 kΩ NTC thermistors: freezer compartment thawed Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance on. Hold SuperFrost (or Alarm) for 5 seconds until 'c' or 'C' menu appears. Press Up/Down to navigate to '0' or 'rS', then press SuperFrost for 3 seconds to clear the fault log and exit service test mode.