Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEi60
Arthur Martin
Arthur Martin // OFFICIAL DIAGNOSTIC BENCH

Arthur Martin Dishwasher i60

DishwasherNTC Temperature Sensor & Thermistor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Electrolux Group: Equivalent Code Across OEM Group Brands
EWM / EDW / EDR Shared Electronic Architecture
AEGi60Electroluxi60Zanussii60Faurei60Zoppasi60Castori60
Other Brands Sharing Code i60:V-ZugI60SchulthessI60AirluxI60FavoritI60ForsI60

Symptom / Description

FAULT

Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water heating general malfunction i60; wash water fails to heat to target temperature within cycle window.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Arthur Martin (Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher) models: Flow-through heating element open circuit (nominal 25–28 Ω, ~2000W), tripped Klixon safety thermostat, heating relay contact burnt on PCB, or NTC failure.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Measure resistance across heater element terminals with multimeter (nominal 25–28 Ω). Check continuity of inline thermal fuses (< 1 Ω). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Arthur Martin Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Arthur Martin I60

FAQ TREE
What does error code I60 mean on a Arthur Martin appliance?

Arthur Martin error code I60 indicates: Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water heating general malfunction i60; wash water fails to heat to target temperature within cycle window..

What is the root cause of Arthur Martin error code I60?

The primary root cause for Arthur Martin code I60 is: On Arthur Martin (Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher) models: Flow-through heating element open circuit (nominal 25–28 Ω, ~2000W), tripped Klixon safety thermostat, heating relay contact burnt on PCB, or NTC failure..

How do I fix or resolve Arthur Martin error code I60?

To resolve error code I60: Measure resistance across heater element terminals with multimeter (nominal 25–28 Ω). Check continuity of inline thermal fuses (< 1 Ω). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.

Is it safe to clear Arthur Martin error code I60 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Arthur Martin code I60 persists, the physical component causing On Arthur Martin (Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher) models: Flow-through heating element open circuit (nominal 25–28 Ω, ~2000W), tripped Klixon safety thermostat, heating relay contact burnt on PCB, or NTC failure. must be inspected or replaced.

How do I test electrical resistance for Arthur Martin code I60 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Arthur Martin code I60?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ARTHUR MARTIN

Related Arthur Martin Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

i61Dishwasher
NTC Temperature Sensor & Thermistor
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Heating timeout or insuffic...
Inspect Protocol
i63Dishwasher
NTC Temperature Sensor & Thermistor
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water heating temperature s...
Inspect Protocol
i64Dishwasher
Heating Element, Thermostat & Safety Fuse
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Heating element relay conta...
Inspect Protocol
i70Dishwasher
NTC Temperature Sensor & Thermistor
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Wash tub NTC temperature th...
Inspect Protocol
i80Dishwasher
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: EEPROM communication fault ...
Inspect Protocol
i90Dishwasher
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: User interface display boar...
Inspect Protocol
iA0Dishwasher
Drive Motor, Inverter & Tachometer Sensor
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Lower spray arm rotation se...
Inspect Protocol
iB0Dishwasher
General System & Mechanical Integration
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Turbidity optical sensor ca...
Inspect Protocol
iC0Dishwasher
Electronic Control Board (PCB) & Bus Communications
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: User interface logic protoc...
Inspect Protocol
iD0Dishwasher
Drive Motor, Inverter & Tachometer Sensor
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Tachometer signal missing f...
Inspect Protocol
iF0Dishwasher
Water Inlet Valve, Aquastop & Flowmeter
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water fill timeout due to s...
Inspect Protocol
iF1Dishwasher
Water Level Pressure Switch & Air Dome
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water level overfill warnin...
Inspect Protocol
AL5Dishwasher
Water Level Pressure Switch & Air Dome
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water fill failure AL5 (leg...
Inspect Protocol
AL6Dishwasher
Heating Element, Thermostat & Safety Fuse
Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water heating failure AL6 (...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.