OEM VERIFIED BENCH
OFFICIAL FAULT CODEE10
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch Dishwasher E10

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
BSH Group: Equivalent Code Across OEM Group Brands
BSH Electronic Architecture (Bosch / Siemens / Neff / Gaggenau)
SiemensE10NeffE10GaggenauE10
Other Brands Sharing Code E10:SamsungE10LGE10ElectroluxE10AEGE10BekoE10HaierE10CandyE10V-ZugE10

Symptom / Description

FAULT

Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Scale build-up on heating element E10; reduced heat transfer efficiency and slow water temperature rise.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bosch dishwashers: Heavy lime scale deposit insulating heating element surface, depleted softening salt in ion exchanger, or hard water setting wrong.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Refill salt container with coarse dishwasher salt. Run intensive descaling cycle with citric acid descaler. Check hardness setting according to local water supply. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E10

FAQ TREE
What does error code E10 mean on a Bosch appliance?

Bosch error code E10 indicates: Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Scale build-up on heating element E10; reduced heat transfer efficiency and slow water temperature rise..

What is the root cause of Bosch error code E10?

The primary root cause for Bosch code E10 is: On Bosch dishwashers: Heavy lime scale deposit insulating heating element surface, depleted softening salt in ion exchanger, or hard water setting wrong..

How do I fix or resolve Bosch error code E10?

To resolve error code E10: Refill salt container with coarse dishwasher salt. Run intensive descaling cycle with citric acid descaler. Check hardness setting according to local water supply. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.

Is it safe to clear Bosch error code E10 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E10 persists, the physical component causing On Bosch dishwashers: Heavy lime scale deposit insulating heating element surface, depleted softening salt in ion exchanger, or hard water setting wrong. must be inspected or replaced.

How do I test electrical resistance for Bosch code E10 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Bosch code E10?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Bosch error code E10 mean on a Dishwasher?

Bosch error code E10 on a Dishwasher indicates: Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Scale build-up on heating element E10; reduced heat transfer efficiency and slow water temperature rise.. Primary cause: On Bosch dishwashers: Heavy lime scale deposit insulating heating element surface, depleted softening salt in ion exchanger, or hard water setting wrong.. Recommended solution: Refill salt container with coarse dishwasher salt. Run intensive descaling cycle with citric acid descaler. Check hardness setting according to local water supply. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off..

What does Bosch error code E10 mean on a Refrigerator / Freezer?

Bosch error code E10 on a Refrigerator / Freezer indicates: Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Compressor inverter communication failure E10; master control board loses serial telemetry link with inverter PCB.. Primary cause: On Bosch refrigerators: Broken PWM control harness between main PCB and compressor inverter box, blown auxiliary power fuse, or failed optocoupler.. Recommended solution: Check PWM control signal wiring continuity between main PCB and inverter module (< 0.5 Ω). Measure frequency/voltage on PWM pins (approx. 2–5V pulse). Press and hold Super/Alarm Off button for 10 seconds until acoustic chime confirms fault log reset..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Bosch E10 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Bosch E10 — Dishwasher

[ACTIVE]
Symptom / Description:

Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Scale build-up on heating element E10; reduced heat transfer efficiency and slow water temperature rise.

Root Cause:

On Bosch dishwashers: Heavy lime scale deposit insulating heating element surface, depleted softening salt in ion exchanger, or hard water setting wrong.

Repair Instructions:

Refill salt container with coarse dishwasher salt. Run intensive descaling cycle with citric acid descaler. Check hardness setting according to local water supply. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.

Bosch E10 — Refrigerator / Freezer

Symptom / Description:

Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Compressor inverter communication failure E10; master control board loses serial telemetry link with inverter PCB.

Root Cause:

On Bosch refrigerators: Broken PWM control harness between main PCB and compressor inverter box, blown auxiliary power fuse, or failed optocoupler.

Repair Instructions:

Check PWM control signal wiring continuity between main PCB and inverter module (< 0.5 Ω). Measure frequency/voltage on PWM pins (approx. 2–5V pulse). Press and hold Super/Alarm Off button for 10 seconds until acoustic chime confirms fault log reset.

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E11Dishwasher
NTC Temperature Sensor & Thermistor
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: NTC temperature sensor f...
Inspect Protocol
E13Dishwasher
NTC Temperature Sensor & Thermistor
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: High water inlet tempera...
Inspect Protocol
E14Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Flowmeter turbine impuls...
Inspect Protocol
E15Dishwasher
Water Level Pressure Switch & Air Dome
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: AquaStop safety flood pr...
Inspect Protocol
E16Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Uncontrolled water inflo...
Inspect Protocol
E17Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: High water inlet pressur...
Inspect Protocol
E18Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Low water flow inlet tim...
Inspect Protocol
E19Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Dispenser actuator / hea...
Inspect Protocol
E20Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Circulation pump BLDC wi...
Inspect Protocol
E21Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Circulation pump motor j...
Inspect Protocol
E22Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Sump filter blocked / re...
Inspect Protocol
E23Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain pump winding resis...
Inspect Protocol
E24Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain hose obstruction /...
Inspect Protocol
E25Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain pump impeller lock...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy