OEM VERIFIED BENCH
OFFICIAL FAULT CODEE31
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch Dishwasher E31

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
BSH Group: Equivalent Code Across OEM Group Brands
BSH Electronic Architecture (Bosch / Siemens / Neff / Gaggenau)
SiemensE31NeffE31GaggenauE31
Other Brands Sharing Code E31:ElectroluxE31AEGE31ZanussiE31Arthur MartinE31CastorE31FaureE31ForsE31

Symptom / Description

FAULT

Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith heat pump overheating safety trip E31; thermal cutout on drying container activated.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bosch dishwashers: Blocked drying air inlet or exhaust inside tub, fan blower failed during regeneration, or water entered zeolite container.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check drying air outlet cap in right rear corner of tub for obstructions. Measure Zeolith heater resistance (nominal ~35–45 Ω). Check thermal fuse continuity. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E31

FAQ TREE
What does error code E31 mean on a Bosch appliance?

Bosch error code E31 indicates: Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith heat pump overheating safety trip E31; thermal cutout on drying container activated..

What is the root cause of Bosch error code E31?

The primary root cause for Bosch code E31 is: On Bosch dishwashers: Blocked drying air inlet or exhaust inside tub, fan blower failed during regeneration, or water entered zeolite container..

How do I fix or resolve Bosch error code E31?

To resolve error code E31: Check drying air outlet cap in right rear corner of tub for obstructions. Measure Zeolith heater resistance (nominal ~35–45 Ω). Check thermal fuse continuity. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.

Is it safe to clear Bosch error code E31 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E31 persists, the physical component causing On Bosch dishwashers: Blocked drying air inlet or exhaust inside tub, fan blower failed during regeneration, or water entered zeolite container. must be inspected or replaced.

How do I test electrical resistance for Bosch code E31 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Bosch code E31?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Bosch error code E31 mean on a Dishwasher?

Bosch error code E31 on a Dishwasher indicates: Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith heat pump overheating safety trip E31; thermal cutout on drying container activated.. Primary cause: On Bosch dishwashers: Blocked drying air inlet or exhaust inside tub, fan blower failed during regeneration, or water entered zeolite container.. Recommended solution: Check drying air outlet cap in right rear corner of tub for obstructions. Measure Zeolith heater resistance (nominal ~35–45 Ω). Check thermal fuse continuity. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off..

What does Bosch error code E31 mean on a Washing Machine?

Bosch error code E31 on a Washing Machine indicates: Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Maximum safety water level exceeded E31; overflow protection trips, inlet valves closed and drain pump energized.. Primary cause: On Bosch washers: Mechanically jammed inlet solenoid valve seat, shorted inlet triac continuing to feed coil, or clogged air trap creating false pressure.. Recommended solution: Shut off water tap. If water continues filling while unplugged, replace defective inlet valve assembly. If water stops when unplugged, replace power PCB. Turn dial to 6 o'clock (down), hold Spin button, rotate to 7 o'clock, release Spin button, turn to 12 o'clock (Off)..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Bosch E31 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Bosch E31 — Dishwasher

[ACTIVE]
Symptom / Description:

Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith heat pump overheating safety trip E31; thermal cutout on drying container activated.

Root Cause:

On Bosch dishwashers: Blocked drying air inlet or exhaust inside tub, fan blower failed during regeneration, or water entered zeolite container.

Repair Instructions:

Check drying air outlet cap in right rear corner of tub for obstructions. Measure Zeolith heater resistance (nominal ~35–45 Ω). Check thermal fuse continuity. Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.

Bosch E31 — Washing Machine

Symptom / Description:

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Maximum safety water level exceeded E31; overflow protection trips, inlet valves closed and drain pump energized.

Root Cause:

On Bosch washers: Mechanically jammed inlet solenoid valve seat, shorted inlet triac continuing to feed coil, or clogged air trap creating false pressure.

Repair Instructions:

Shut off water tap. If water continues filling while unplugged, replace defective inlet valve assembly. If water stops when unplugged, replace power PCB. Turn dial to 6 o'clock (down), hold Spin button, rotate to 7 o'clock, release Spin button, turn to 12 o'clock (Off).

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E3100Dishwasher
NTC Temperature Sensor & Thermistor
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith container NTC se...
Inspect Protocol
E3200Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Zeolith regeneration hea...
Inspect Protocol
E6101Dishwasher
Water Level Pressure Switch & Air Dome
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Drain safety monitoring ...
Inspect Protocol
E6900Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Main inverter power modu...
Inspect Protocol
E9001Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Low voltage DC power rai...
Inspect Protocol
E9210Dishwasher
Drainage System & Drain Pump
Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Water hardness ion-excha...
Inspect Protocol
HDishwasher
Electronic Control Board (PCB) & Bus Communications
After the flash fires, "H" appears on the display
Inspect Protocol
h:00 – h:24Dishwasher
Drainage System & Drain Pump
Delay start countdown display active (h:00 to h:24); wash cycle execution deferred.
Inspect Protocol
P0 Switchmirror 1Dishwasher
Electronic Control Board (PCB) & Bus Communications
Error message „P0 Switchmirror 1“ or barre colorate south display with capacitive control pa...
Inspect Protocol
1Dishwasher
Electronic Control Board (PCB) & Bus Communications
Error in the Aquasensor system (Error in Aquasensor system)
Inspect Protocol
16Dishwasher
Electronic Control Board (PCB) & Bus Communications
Bosch 16: Operational cycle fault detected during Dishwasher program execution.
Inspect Protocol
2Dishwasher
Electronic Control Board (PCB) & Bus Communications
Heizfehler (Heating error)
Inspect Protocol
4Dishwasher
Water Level Pressure Switch & Air Dome
Bosch 4: Water inlet / filling timeout in Dishwasher; appliance fails to fill to minimum ope...
Inspect Protocol
8Dishwasher
NTC Temperature Sensor & Thermistor
Fault detected in the NTC temperature sensor circuit
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy