Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Castor I10
FAQ TREEWhat does error code I10 mean on a Castor appliance?
Castor error code I10 indicates: Castor CDF Series / Lavastoviglie Silenziosa Dishwasher: Water fill timeout error i10; appliance fails to reach operational water fill level within 180 seconds..
What is the root cause of Castor error code I10?
The primary root cause for Castor code I10 is: On Castor (Castor CDF Series / Lavastoviglie Silenziosa Dishwasher) models: Closed water tap, kinked supply hose, clogged inlet filter, defective AquaStop solenoid valve (nominal 3.8–4.4 kΩ), or blocked pressure sensor hose..
How do I fix or resolve Castor error code I10?
To resolve error code I10: Check water tap pressure. Clean mesh filter in AquaStop coupling. Measure solenoid valve coil resistance with multimeter (3.8–4.4 kΩ). Hold Start and Reset keys for 5 seconds until the display clears the alarm code and restores standby status.
Is it safe to clear Castor error code I10 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Castor code I10 persists, the physical component causing On Castor (Castor CDF Series / Lavastoviglie Silenziosa Dishwasher) models: Closed water tap, kinked supply hose, clogged inlet filter, defective AquaStop solenoid valve (nominal 3.8–4.4 kΩ), or blocked pressure sensor hose. must be inspected or replaced.
How do I test electrical resistance for Castor code I10 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Castor code I10?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?