Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEd13
FAGOR
FAGOR // OFFICIAL DIAGNOSTIC BENCH

FAGOR Dishwasher d13

DishwasherNTC Temperature Sensor & Thermistor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Brandt / Fagor Group: Equivalent Code Across OEM Group Brands
Groupe Brandt / Fagor Shared Electronic Platform
Brandtd13De Dietrichd13Sauterd13
Other Brands Sharing Code d13:ArdoD13BlueskyD13OceanD13SametD13

Symptom / Description

FAULT

Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water temperature overheating cutoff d13; sump temperature exceeds 75°C safety threshold during cycle.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Welded power relay contacts powering heater continuously, or short-circuited NTC thermistor.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect power immediately. Measure heater relay contact continuity with power off (must be open). Test NTC resistance (~47 kΩ at 25°C). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide FAGOR Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: FAGOR D13

FAQ TREE
What does error code D13 mean on a FAGOR appliance?

FAGOR error code D13 indicates: Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water temperature overheating cutoff d13; sump temperature exceeds 75°C safety threshold during cycle..

What is the root cause of FAGOR error code D13?

The primary root cause for FAGOR code D13 is: On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Welded power relay contacts powering heater continuously, or short-circuited NTC thermistor..

How do I fix or resolve FAGOR error code D13?

To resolve error code D13: Disconnect power immediately. Measure heater relay contact continuity with power off (must be open). Test NTC resistance (~47 kΩ at 25°C). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.

Is it safe to clear FAGOR error code D13 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if FAGOR code D13 persists, the physical component causing On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Welded power relay contacts powering heater continuously, or short-circuited NTC thermistor. must be inspected or replaced.

How do I test electrical resistance for FAGOR code D13 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing FAGOR code D13?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does FAGOR error code d13 mean on a Dishwasher?

FAGOR error code d13 on a Dishwasher indicates: Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water temperature overheating cutoff d13; sump temperature exceeds 75°C safety threshold during cycle.. Primary cause: On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Welded power relay contacts powering heater continuously, or short-circuited NTC thermistor.. Recommended solution: Disconnect power immediately. Measure heater relay contact continuity with power off (must be open). Test NTC resistance (~47 kΩ at 25°C). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off..

What does FAGOR error code d13 mean on a Tumble Dryer?

FAGOR error code d13 on a Tumble Dryer indicates: Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Drum drive belt broken or tensioner open d13; motor spins freely but drum does not rotate.. Primary cause: On FAGOR tumble dryers utilizing Innova thermodynamic refrigeration circuit, dual conductivity sensor bars, and reversible drum rotation: Snapped poly-V drive belt, fallen tensioner pulley tripping the safety microswitch, or seized idler bearing.. Recommended solution: Remove side or top panel. Check belt integrity around drum. Fit new poly-V belt over motor pulley and reset the tensioner microswitch arm. Turn dial to Off position, hold Start and Anti-Crease buttons together for 6 seconds until buzzer beeps, then turn back on..

What does FAGOR error code d13 mean on a Washing Machine?

FAGOR error code d13 on a Washing Machine indicates: Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Spin unbalance cutoff d13; drum spin ramp is terminated repeatedly due to uneven laundry mass distribution.. Primary cause: On FAGOR washing machines utilizing Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Single large heavy item (bath mat, pillow), worn drum friction dampers, or broken suspension springs.. Recommended solution: Untangle laundry and add smaller items to balance load. Inspect tub shock absorbers for damping resistance. Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart..

Community Verification

COMMUNITY

Did this solution resolve the issue?

FAGOR d13 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

FAGOR d13 — Dishwasher

[ACTIVE]
Symptom / Description:

Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water temperature overheating cutoff d13; sump temperature exceeds 75°C safety threshold during cycle.

Root Cause:

On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Welded power relay contacts powering heater continuously, or short-circuited NTC thermistor.

Repair Instructions:

Disconnect power immediately. Measure heater relay contact continuity with power off (must be open). Test NTC resistance (~47 kΩ at 25°C). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.

FAGOR d13 — Dryer

Symptom / Description:

Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Drum drive belt broken or tensioner open d13; motor spins freely but drum does not rotate.

Root Cause:

On FAGOR tumble dryers utilizing Innova thermodynamic refrigeration circuit, dual conductivity sensor bars, and reversible drum rotation: Snapped poly-V drive belt, fallen tensioner pulley tripping the safety microswitch, or seized idler bearing.

Repair Instructions:

Remove side or top panel. Check belt integrity around drum. Fit new poly-V belt over motor pulley and reset the tensioner microswitch arm. Turn dial to Off position, hold Start and Anti-Crease buttons together for 6 seconds until buzzer beeps, then turn back on.

FAGOR d13 — Washing Machine

Symptom / Description:

Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Spin unbalance cutoff d13; drum spin ramp is terminated repeatedly due to uneven laundry mass distribution.

Root Cause:

On FAGOR washing machines utilizing Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Single large heavy item (bath mat, pillow), worn drum friction dampers, or broken suspension springs.

Repair Instructions:

Untangle laundry and add smaller items to balance load. Inspect tub shock absorbers for damping resistance. Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart.

SEMANTIC KNOWLEDGE GRAPH // FAGOR

Related FAGOR Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

d14Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash pump cavitation / water fill discrepa...
Inspect Protocol
F1Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water inlet pressure drop error F1; flowme...
Inspect Protocol
F2Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump water evacuation timeout F2; water re...
Inspect Protocol
F3Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Heating system malfunction F3; temperature...
Inspect Protocol
F4Dishwasher
NTC Temperature Sensor & Thermistor
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump NTC sensor open or short circuit F4; ...
Inspect Protocol
F5Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Circulation wash motor electrical fault F5...
Inspect Protocol
F6Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous water entry / water level safet...
Inspect Protocol
i20Dishwasher
Drainage System & Drain Pump
Fagor Dishwasher beeps and stops with fault code 'i20'; dirty water remains pooled in the bo...
Inspect Protocol
i30Dishwasher
Drainage System & Drain Pump
Fagor Dishwasher triggers emergency drain pump and displays 'i30'; machine cannot be restart...
Inspect Protocol
C3Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Dishwasher displays 'C3' and runs drain pump continuously even with door open or power...
Inspect Protocol
d01Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water fill timeout d01; appliance fails to...
Inspect Protocol
d02Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Drain pump timeout d02; dirty wash water r...
Inspect Protocol
d03Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash heating system failure d03; water rem...
Inspect Protocol
d04Dishwasher
NTC Temperature Sensor & Thermistor
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump NTC temperature thermistor fault d04;...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy