Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E34
FAQ TREEWhat does error code E34 mean on a Faure appliance?
Faure error code E34 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Level incongruence alarm E34; mismatch between analog sensor frequency and anti-overflow safety switch..
What is the root cause of Faure error code E34?
The primary root cause for Faure code E34 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Anti-overflow mechanical contact stuck open or closed, analog sensor calibration drifted, or electrical noise on analog signal line..
How do I fix or resolve Faure error code E34?
To resolve error code E34: Test continuity of mechanical anti-overflow switch contacts (should be closed at rest < 1 Ω). Verify analog pressure sensor frequency (~43.5 Hz empty). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E34 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E34 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Anti-overflow mechanical contact stuck open or closed, analog sensor calibration drifted, or electrical noise on analog signal line. must be inspected or replaced.
How do I test electrical resistance for Faure code E34 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Faure code E34?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



