Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Franke E14
FAQ TREEWhat does error code E14 mean on a Franke appliance?
Franke error code E14 indicates: Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E14 registered by the microcomputer controller. Water inlet flowrate exceeding maximum safety threshold (>10 bar).
What is the root cause of Franke error code E14?
The primary root cause for Franke code E14 is: On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: household water pressure excessively high Metrological tolerance verification: flow rate > 5 L/min...
How do I fix or resolve Franke error code E14?
To resolve error code E14: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: install water pressure regulator on supply line if pressure exceeds 5 bar. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold Start/Pause for 5 seconds until the display shows '0:01' or cancels the cycle. Close the door to allow 60 seconds of drain down, then switch off power for 30 seconds before restarting.
Is it safe to clear Franke error code E14 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Franke code E14 persists, the physical component causing On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: household water pressure excessively high Metrological tolerance verification: flow rate > 5 L/min.. must be inspected or replaced.
How do I test electrical resistance for Franke code E14 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Franke code E14?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?