Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE16
Franke
Franke // OFFICIAL DIAGNOSTIC BENCH

Franke E16

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code E16:BoschE16SiemensE16SamsungE16LGE16BekoE16HaierE16CandyE16NeffE16V-ZugE16HooverE16

Symptom / Description

FAULT

Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E16 registered by the microcomputer controller. Door lock latch switch open during wash cycle

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: door latch switch contacts open Metrological tolerance verification: microswitch continuity 0.0 Ω closed..

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check door latch alignment and test microswitch continuity. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold Start/Pause for 5 seconds until the display shows '0:01' or cancels the cycle. Close the door to allow 60 seconds of drain down, then switch off power for 30 seconds before restarting.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Franke Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Franke E16

FAQ TREE
What does error code E16 mean on a Franke appliance?

Franke error code E16 indicates: Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E16 registered by the microcomputer controller. Door lock latch switch open during wash cycle.

What is the root cause of Franke error code E16?

The primary root cause for Franke code E16 is: On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: door latch switch contacts open Metrological tolerance verification: microswitch continuity 0.0 Ω closed...

How do I fix or resolve Franke error code E16?

To resolve error code E16: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check door latch alignment and test microswitch continuity. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold Start/Pause for 5 seconds until the display shows '0:01' or cancels the cycle. Close the door to allow 60 seconds of drain down, then switch off power for 30 seconds before restarting.

Is it safe to clear Franke error code E16 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Franke code E16 persists, the physical component causing On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: door latch switch contacts open Metrological tolerance verification: microswitch continuity 0.0 Ω closed.. must be inspected or replaced.

How do I test electrical resistance for Franke code E16 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Franke code E16?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FRANKE

Related Franke Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E17Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E17 re...
Inspect Protocol
E18Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E18 re...
Inspect Protocol
E2Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E2 reg...
Inspect Protocol
E3Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E3 reg...
Inspect Protocol
E4Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E4 reg...
Inspect Protocol
E5Water Level Pressure Switch & Air Dome
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E5 reg...
Inspect Protocol
E6NTC Temperature Sensor & Thermistor
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E6 reg...
Inspect Protocol
E7Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E7 reg...
Inspect Protocol
E8Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E8 reg...
Inspect Protocol
E9Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E9 reg...
Inspect Protocol
AL01Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code AL01 r...
Inspect Protocol
E1Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E1 reg...
Inspect Protocol
E10Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E10 re...
Inspect Protocol
E11Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E11 re...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy