OFFICIAL FAULT CODEE5
Franke
Franke // OFFICIAL DIAGNOSTIC BENCH

Franke E5

DishwasherWater Level Pressure Switch & Air Dome
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code E5:BoschE5SiemensE5LGE5WhirlpoolE5ElectroluxE5AEGE5BekoE5IndesitE5HaierE5CandyE5

Symptom / Description

FAULT

Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E5 registered by the microcomputer controller. Water level pressure sensor failure / pressure chamber clogged

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: pressure sensor diaphragm fouled with food soil Metrological tolerance verification: sensor voltage 0.5V DC empty, 2.5V DC full..

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: remove pressure sensor, clean pressure dome with warm water, and test voltage. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold Start/Pause for 5 seconds until the display shows '0:01' or cancels the cycle. Close the door to allow 60 seconds of drain down, then switch off power for 30 seconds before restarting.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Franke Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Level Pressure Switch & Air DomeDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Test Pins & Connections
PROBE (+)
PROBE (-)
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Tolerance & Diagnostic CriteriaMechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Cut 230V mains power before accessing the upper chassis or pressure switch terminals.
  • !Drain appliance tub completely before disconnecting pressure switch sensing hoses.
  • !Never blow high-pressure compressed air into electronic analog pressure sensors: internal diaphragms will rupture!
3. Preliminary Mechanical & Visual Checks
  • Disconnect the silicone pressure tube from the lower air trap and inspect for soap sludge, lint, or water blockage.
  • Inspect the flexible rubber hose along its entire length for pinholes, cracks, or loose clamp fit.
  • Thoroughly flush the lower compression chamber (air dome) with hot water to dissolve detergent buildup.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Franke E5

FAQ TREE
What does error code E5 mean on a Franke appliance?

Franke error code E5 indicates: Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E5 registered by the microcomputer controller. Water level pressure sensor failure / pressure chamber clogged.

What is the root cause of Franke error code E5?

The primary root cause for Franke code E5 is: On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: pressure sensor diaphragm fouled with food soil Metrological tolerance verification: sensor voltage 0.5V DC empty, 2.5V DC full...

How do I fix or resolve Franke error code E5?

To resolve error code E5: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: remove pressure sensor, clean pressure dome with warm water, and test voltage. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold Start/Pause for 5 seconds until the display shows '0:01' or cancels the cycle. Close the door to allow 60 seconds of drain down, then switch off power for 30 seconds before restarting.

Is it safe to clear Franke error code E5 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Franke code E5 persists, the physical component causing On Franke appliances engineered with Dynamic Flow hydraulic wash circuit with BLDC variable-speed circulation wash pump, optical dual turbidity sensor, and active condensation drying turbine: pressure sensor diaphragm fouled with food soil Metrological tolerance verification: sensor voltage 0.5V DC empty, 2.5V DC full.. must be inspected or replaced.

How do I test electrical resistance for Franke code E5 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..

What safety protocol must be followed before servicing Franke code E5?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FRANKE

Related Franke Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E6NTC Temperature Sensor & Thermistor
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E6 reg...
Inspect Protocol
E7Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E7 reg...
Inspect Protocol
E8Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E8 reg...
Inspect Protocol
E9Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E9 reg...
Inspect Protocol
AL01Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code AL01 r...
Inspect Protocol
E1Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E1 reg...
Inspect Protocol
E10Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E10 re...
Inspect Protocol
E11Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E11 re...
Inspect Protocol
E12Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E12 re...
Inspect Protocol
E13Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E13 re...
Inspect Protocol
E14Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E14 re...
Inspect Protocol
E15Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E15 re...
Inspect Protocol
E16Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E16 re...
Inspect Protocol
E17Drainage System & Drain Pump
Franke Mythos FDW / Maris Active Kitchen Integrated Dishwasher: Diagnostic fault code E17 re...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.