Haier E07 — Dishwasher
[ACTIVE]Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Circulation wash pump motor rotation error E07; tachometer sensor sends no pulse feedback to power inverter.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Jammed circulation pump rotor, detached tachometer coil or magnet, or open stator winding phase (~45–95 Ω).
Inspect circulation pump volute chamber for foreign obstructions. Measure stator windings resistance (~45–95 Ω across phases). Verify tach coil (~100–180 Ω). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.