Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Ignis F23
FAQ TREEWhat does error code F23 mean on a Ignis appliance?
Ignis error code F23 indicates: Machine overfills or does not fill with enough water.
What is the root cause of Ignis error code F23?
The primary root cause for Ignis code F23 is: Pressure switch fault. The switch that senses the water level is providing an incorrect reading..
How do I fix or resolve Ignis error code F23?
To resolve error code F23: Check the pressure switch hose for blockages or splits. Inspect wiring to the pressure switch. Replace the pressure switch if faulty.
Is it safe to clear Ignis error code F23 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ignis code F23 persists, the physical component causing Pressure switch fault. The switch that senses the water level is providing an incorrect reading. must be inspected or replaced.
How do I test electrical resistance for Ignis code F23 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Ignis code F23?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.