OEM VERIFIED BENCH
OFFICIAL FAULT CODEF2
Rosieres
Rosieres // OFFICIAL DIAGNOSTIC BENCH

Rosieres F2

DryerNTC Temperature Sensor & Thermistor
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code F2:BoschF2MieleF2SiemensF2LGF2WhirlpoolF2ElectroluxF2AEGF2BekoF2IndesitF2HaierF2

Symptom / Description

FAULT

Rosières RLE Heat-Pump Tumble Dryer: Rear exhaust temperature sensor fault F2; exhaust air probe sends corrupted or out-of-range temperature signal.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Rosières dryers utilizing RLE thermodynamic heat-pump condensation circuit, precision electronic moisture sensor, and low-vibration chassis: Defective rear duct NTC thermistor, damaged sensor wire harness near heater chamber, or connector corrosion.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check rear duct probe resistance (~10 kΩ–20 kΩ at 25°C). Inspect sensor lead routing to ensure no heat damage from rear element. Set program dial to 12 o'clock (Off), press and hold Start and Delicate buttons for 5 seconds until double tone sounds, then release.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Rosieres Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Rosieres F2

FAQ TREE
What does error code F2 mean on a Rosieres appliance?

Rosieres error code F2 indicates: Rosières RLE Heat-Pump Tumble Dryer: Rear exhaust temperature sensor fault F2; exhaust air probe sends corrupted or out-of-range temperature signal..

What is the root cause of Rosieres error code F2?

The primary root cause for Rosieres code F2 is: On Rosières dryers utilizing RLE thermodynamic heat-pump condensation circuit, precision electronic moisture sensor, and low-vibration chassis: Defective rear duct NTC thermistor, damaged sensor wire harness near heater chamber, or connector corrosion..

How do I fix or resolve Rosieres error code F2?

To resolve error code F2: Check rear duct probe resistance (~10 kΩ–20 kΩ at 25°C). Inspect sensor lead routing to ensure no heat damage from rear element. Set program dial to 12 o'clock (Off), press and hold Start and Delicate buttons for 5 seconds until double tone sounds, then release.

Is it safe to clear Rosieres error code F2 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code F2 persists, the physical component causing On Rosières dryers utilizing RLE thermodynamic heat-pump condensation circuit, precision electronic moisture sensor, and low-vibration chassis: Defective rear duct NTC thermistor, damaged sensor wire harness near heater chamber, or connector corrosion. must be inspected or replaced.

How do I test electrical resistance for Rosieres code F2 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Rosieres code F2?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ROSIÈRES

Related Rosières Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F3NTC Temperature Sensor & Thermistor
Rosières RLE Heat-Pump Tumble Dryer: Compressor discharge pipe high-temperature limit exceed...
Inspect Protocol
F4Water Level Pressure Switch & Air Dome
Rosières RLE Heat-Pump Tumble Dryer: Condensate evacuation pump failure F4; water level swit...
Inspect Protocol
F5Drive Motor, Inverter & Tachometer Sensor
Rosières RLE Heat-Pump Tumble Dryer: Motor / compressor inverter communication timeout F5; m...
Inspect Protocol
F6Drive Motor, Inverter & Tachometer Sensor
Rosières RLE Heat-Pump Tumble Dryer: Auxiliary heat-pump cooling fan fault F6; compressor co...
Inspect Protocol
E01Heating Element, Thermostat & Safety Fuse
Rosières RLE Heat-Pump Tumble Dryer: Airflow restriction warning E01; door lint filter clogg...
Inspect Protocol
E02NTC Temperature Sensor & Thermistor
Rosières RLE Heat-Pump Tumble Dryer: Process air duct NTC sensor error E02; thermistor signa...
Inspect Protocol
E03General System & Mechanical Integration
Rosières RLE Heat-Pump Tumble Dryer: Maximum drying cycle time exceeded E03; machine aborts ...
Inspect Protocol
E04Heating Element, Thermostat & Safety Fuse
Rosières RLE Heat-Pump Tumble Dryer: Heating circuit safety lockout E04; heater relay contac...
Inspect Protocol
E05NTC Temperature Sensor & Thermistor
Rosières RLE Heat-Pump Tumble Dryer: Heat pump compressor thermistor fault E05; suction / di...
Inspect Protocol
E06Drive Motor, Inverter & Tachometer Sensor
Rosières RLE Heat-Pump Tumble Dryer: Drum motor drive failure E06; motor hums but fails to r...
Inspect Protocol
E07Drainage System & Drain Pump
Rosières RLE Heat-Pump Tumble Dryer: Drum rotation sensor speed feedback missing E07; contro...
Inspect Protocol
E08Heating Element, Thermostat & Safety Fuse
Rosières RLE Heat-Pump Tumble Dryer: Rear heater safety Klixon thermostat open E08; high-lim...
Inspect Protocol
E09Drive Motor, Inverter & Tachometer Sensor
Rosières RLE Heat-Pump Tumble Dryer: Drum motor drive semiconductor failure E09; motor triac...
Inspect Protocol
E10Door Lock Mechanism & Safety Interlock
Rosières RLE Heat-Pump Tumble Dryer: Moisture sensing conductivity circuit error E10; sensor...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy