Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Sauter D10
FAQ TREEWhat does error code D10 mean on a Sauter appliance?
Sauter error code D10 indicates: Sauter Silence / SVH / Saveurs Built-in Dishwasher: Continuous uncontrolled water fill d10; water continues entering appliance after target fill level is achieved..
What is the root cause of Sauter error code D10?
The primary root cause for Sauter code D10 is: On Sauter dishwashers featuring Saveurs alternating hydraulic wash arms, Flexi-Safe load geometry, and 42dB acoustic shielding: Debris wedging inlet valve plunger open, shorted inlet triac on PCB, or leaking valve diaphragm..
How do I fix or resolve Sauter error code D10?
To resolve error code D10: Shut off water tap immediately. Check if water continues flowing with power turned off (proves mechanical valve seat leak). Replace inlet valve. Press and hold the Start/Reset button for 4 seconds until drain pump initiates, allow pumpout to complete, then switch off.
Is it safe to clear Sauter error code D10 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Sauter code D10 persists, the physical component causing On Sauter dishwashers featuring Saveurs alternating hydraulic wash arms, Flexi-Safe load geometry, and 42dB acoustic shielding: Debris wedging inlet valve plunger open, shorted inlet triac on PCB, or leaking valve diaphragm. must be inspected or replaced.
How do I test electrical resistance for Sauter code D10 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Sauter code D10?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?