Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Sauter D02
FAQ TREEWhat does error code D02 mean on a Sauter appliance?
Sauter error code D02 indicates: Sauter Silence / SVH / Saveurs Built-in Dishwasher: Drain pump timeout d02; dirty wash water remains pooled in the sump tub after 3 minutes of pumpout..
What is the root cause of Sauter error code D02?
The primary root cause for Sauter code D02 is: On Sauter dishwashers featuring Saveurs alternating hydraulic wash arms, Flexi-Safe load geometry, and 42dB acoustic shielding: Bone fragment or glass shard wedging the drain impeller, kinked drain tube, or open drain motor winding (~180–220 Ω)..
How do I fix or resolve Sauter error code D02?
To resolve error code D02: Remove microfilter basket and reach into sump to clear debris from impeller. Measure drain pump winding resistance (~180–220 Ω). Press and hold the Start/Reset button for 4 seconds until drain pump initiates, allow pumpout to complete, then switch off.
Is it safe to clear Sauter error code D02 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Sauter code D02 persists, the physical component causing On Sauter dishwashers featuring Saveurs alternating hydraulic wash arms, Flexi-Safe load geometry, and 42dB acoustic shielding: Bone fragment or glass shard wedging the drain impeller, kinked drain tube, or open drain motor winding (~180–220 Ω). must be inspected or replaced.
How do I test electrical resistance for Sauter code D02 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Sauter code D02?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?