Siemens E25 — Dishwasher
[ACTIVE]Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain pump impeller locked / pump cover missing E25; wastewater cannot be pumped out, standing water in tub bottom.
On Siemens dishwashers: Fruit seeds, small bone fragments, or glass shards jamming drain impeller, or white impeller cover dislodged during cleaning.
Scoop out standing water. Remove filter, lever off white pump cover with teaspoon, wear gloves to clear glass/debris from impeller, snap cover back. Press and hold Start button for 4 seconds until display indicates '0:01', wait for evacuation pump, then power off.