Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
V-Zug • Central Diagnostic Dictionary
165 Verified Codes in Database

V-Zug Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for V-Zug appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
E03
Hob / Cooktop
Heating Element, Thermostat & Safety Fuse

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Power module IGBT inverter transistor short circuit E03; appliance trips home breaker instantly when zone power is dialed up.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: Collector-Emitter thermal punch-through (<1 Ω) in one or more 1200V IGBT transistors or shorted bridge rectifier.

Measure C-E resistance of all IGBTs on aluminum heatsink with diode tester: low resistance (<100 Ω) confirms puncture. Replace blown IGBTs and gate drive resistors or swap power board. Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E03
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Tangential cooling fan motor failure E03; electronic safety cuts off heating to prevent control panel and casing overheating.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Seized tangential fan roller bearings, burned motor winding (~160–240 Ω), or failed Hall effect tachometer feedback sensor.

Inspect fan rotor for mechanical binding. Measure motor coil resistance (~160–240 Ω). Verify tachometer signal pulses with oscilloscope or multimeter frequency mode. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E03
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Defrost termination evaporator sensor fault E03; evaporator coil freezes solid with ice, choking air circulation vents.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Defrost NTC sensor clipped to evaporator header pipe open (~5 kΩ at 25°C, ~16 kΩ at 0°C), preventing defrost cycle execution.

Manually defrost evaporator using steam/heat gun. Measure sensor resistance: expected ~16.3 kΩ in iced water (0°C). Replace sensor firmly clipped to aluminum tube. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E03
Washing Machine
Drainage System & Drain Pump

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Drainage timeout error E03; waste wash water remains in tub after 4 minutes of drain pump activation.

On V-ZUG washing machines featuring AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Blocked coin filter, foreign object jamming impeller, kinked drain line, or open pump motor coil (~150–220 Ω).

Unscrew and clean bottom coin filter. Verify free impeller spin by hand. Measure drain pump winding resistance with multimeter (~150–220 Ω). Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E3
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-Zug E3: Cooling circuit or defrost system anomaly in Refrigerator / Freezer; compartment temperature deviation.

On V-Zug Refrigerator: The temperature sensor for the freezer compartment is defective.

On V-Zug Refrigerator: The cooling system will run in an emergency mode. Contact a service technician to have the sensor replaced.

Diagnose
E04
Dishwasher
Drainage System & Drain Pump

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Base pan leak detection E04; polystyrene float switch in bottom drip tray activates emergency continuous drainage.

On V-ZUG dishwashers utilizing AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Leaking circulation pump shaft seal, cracked sump gasket, split spray arm joint, or loose hose clamp.

Unplug unit. Tilt machine backward 45° onto a towel to drain base pan. Inspect circulation pump volute and sump perimeter for chalky leak trails. Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
E04
Tumble Dryer
NTC Temperature Sensor & Thermistor

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: Process air NTC temperature sensor fault E04; machine aborts cycle after 2 minutes or overheats and triggers safety trip.

On V-ZUG dryers featuring AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: NTC sensor open circuit or shorted, wiring harness chaffed against chassis, or resistance drifting beyond curve (standard ~10–20 kΩ at 25°C).

Unplug NTC connector at main board. Measure sensor resistance with multimeter: expected ~10–20 kΩ at 25°C (~4–6 kΩ at 60°C). Replace sensor if out of spec. Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E04
Hob / Cooktop
NTC Temperature Sensor & Thermistor

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Induction coil center temperature probe fault E04; zone display posts error and cuts heating to protect ceramic glass from cracking.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: Spring-loaded center NTC probe open circuit or disconnected (~100 kΩ or ~10 kΩ at 25°C), or sensor silicone cap degraded.

Measure NTC probe resistance across its dual terminals: nominal ~100 kΩ (or ~10 kΩ depending on board version) at 25°C. Check spring contact against underside of glass. Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E04
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Cavity high-limit overtemperature emergency shutoff E04; thermal Klixon trips (>320°C bake / >500°C pyro) completely powering off heating elements.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Welded heating relay keeping element continuously energized, defective cavity sensor under-reading temperature, or jammed cooling airflow.

Allow oven to cool down completely. Reset Klixon if equipped with manual red pin on top casing. Test continuity (<0.5 Ω cold). Check PCB relays for welded contacts. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E04
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Ambient room temperature sensor failure E04; dynamic defrost interval calculations and door heater logic misbehave.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Open or shorted ambient NTC thermistor mounted on top hinge cover or behind display panel (~10 kΩ at 25°C).

Inspect ambient sensor under top hinge cap. Measure resistance at room temperature: expected ~10 kΩ at 25°C (~12.5 kΩ at 20°C). Replace sensor if value is open. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E04
Washing Machine
Drainage System & Drain Pump

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Anti-flood protection triggered E04; safety drain pump runs continuously and program halts due to water in base pan.

On V-ZUG washing machines utilizing AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Internal hydraulic hose split, tub seal degradation, dispenser overflow, or stuck polystyrene base float microswitch.

Disconnect mains power immediately. Tilt unit back 45° to drain base tray. Locate and seal internal hose leak. Test float switch continuity (<1 Ω). Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E05
Dishwasher
NTC Temperature Sensor & Thermistor

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Temperature sensor communication anomaly E05; wash NTC circuit voltage drops to 0V (short) or rises to 5V (open circuit).

On V-ZUG dishwashers featuring AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Defective negative temperature coefficient thermistor bead, corroded plug terminals in sump, or broken harness lead.

Unplug NTC harness plug from sump. Measure resistance across sensor pins: ~10–12 kΩ at 25°C, ~2.5 kΩ at 60°C. Check wiring continuity to PCB. Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
E05
Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: Electronic moisture conductance sensor anomaly E05; program ends prematurely after 3 to 5 minutes with damp clothes inside.

On V-ZUG dryers with AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: Insulating scale or fabric softener film coating the dual stainless steel sensor bars, or worn drum ground slip brush.

Clean stainless sensor electrodes below door opening with white vinegar and fine abrasive pad. Check copper ground carbon brush on top/rear of drum (<2 Ω to earth). Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E05
Hob / Cooktop
General System & Mechanical Integration

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Mains supply voltage high overvoltage protection E05; cooktop beeps and isolates electronic components to prevent catastrophic failure.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: AC input voltage exceeding 275V AC, accidental 400V connection between phase and neutral during installation, or severe line surge.

Immediately disconnect power! Check voltage between Phase (L) and Neutral (N): must be 230V AC (not 400V). Verify neutral jumper bridge on mains terminal block. Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E05
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Bottom sole heating element open circuit E05; bottom crust remains uncooked and lower chamber fails to reach set temperature.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Burned-out bottom heating element wire (~35–50 Ω nominal, 1200–1500W), burnt faston terminal connector, or defective wiring wire loom.

Disconnect power. Access rear or bottom panel. Measure resistance across bottom element terminals: expected ~35–50 Ω (infinite indicates open circuit). Replace element. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E05
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Evaporator defrost heating element open circuit E05; defrost cycle aborts on maximum timer and ice completely encases cooling coil.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Burned-out aluminum sheath or calrod defrost heating element (~180–320 Ω nominal, 150–250W), or corroded silicone end seal plugs.

Disconnect defrost heater wiring leads. Measure resistance across terminals: expected ~180–320 Ω (infinite Ω indicates broken element). Replace heating element assembly. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E05
Washing Machine
NTC Temperature Sensor & Thermistor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Heating malfunction E05; wash water temperature fails to increase by more than 4°C within 15 minutes of heater activation.

On V-ZUG washing machines featuring AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Open tubular wash heating element (~24–32 Ω), open NTC thermistor probe (~12 kΩ at 20°C), or burnt heater relay.

Measure wash heater resistance between terminals (~24–32 Ω). Measure insulation to earth (>2 MΩ). Check NTC thermistor resistance (~12 kΩ at 20°C). Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E06
Dishwasher
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Circulation pump motor stall E06; BLDC wash motor fails to maintain operating spray pressure or draws locked rotor current.

On V-ZUG dishwashers utilizing AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Toothpick or fruit pit wedging circulation turbine, dried detergent sludge, or open motor phase winding (~45–95 Ω).

Inspect circulation pump volute through sump inlet for foreign obstructions. Disconnect motor connector and measure winding phase resistances (~45–95 Ω balanced). Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
E06
Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: Heat pump inverter compressor drive trip E06; compressor attempts startup with vibrating buzz, shuts down, and posts fault.

On V-ZUG heat pump dryers with AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: Inverter module IPM overcurrent, seized scroll/rotary compressor piston, or unequal winding resistance (~3.5–7.0 Ω balanced U-V-W).

Disconnect compressor wiring plug. Measure phase-to-phase winding resistance: all three pairs (U-V, V-W, W-U) must be equal (~3.5–7.0 Ω). Check no short to earth (>10 MΩ). Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E06
Hob / Cooktop
General System & Mechanical Integration

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Mains supply undervoltage condition E06; cooktop drops booster power or shuts off all heating zones under heavy cooking load.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: AC supply voltage dropping below 180V AC under load, loose line wire connection in wall outlet box, or undersized supply wiring.

Measure voltage at junction box while powering two zones: must remain >207V AC. Verify supply wire gauge is minimum 2.5 mm² (or 4 mm² for 7.4 kW mono-phase). Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E06
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Circular convection ring element open circuit E06; hot air convection mode blows cool air without heating chamber.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Thermal fatigue fracture of circular element coil (~22–32 Ω nominal, 2000–2400W), internal short to sheath, or blown supply relay.

Disconnect power. Remove rear cavity baffle plate. Measure resistance of circular element (~22–32 Ω). Check continuity to protective earth ground (>10 MΩ). Replace element. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E06
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Defrost circuit thermal safety fuse opened E06; defrost heater receives no voltage and freezer evaporator rapidly chokes with frost.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: In-line 72°C/77°C thermal fuse blown due to defrost relay stuck on control board or defective defrost termination sensor.

Test thermal fuse continuity with ohmmeter: must be <0.5 Ω (infinite Ω confirms blown fuse). Replace thermal fuse harness and verify defrost relay de-energizes properly. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E06
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Unbalanced load warning E06; spin cycle aborted after multiple distribution attempts due to excessive drum eccentricity.

On V-ZUG washing machines utilizing AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Single heavy textile (blanket, rug), tangled load, worn friction dampers, or weak suspension tub springs.

Pause cycle, untangle and redistribute laundry evenly around drum perimeter. Inspect shock dampers for fluid leaks or lack of friction resistance. Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E07
Dishwasher
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Spray diverter positioning error E07; motorized water switch disc fails to register upper/lower spray arm alternating position.

On V-ZUG dishwashers featuring AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Jammed disc gear train, oxidized position microswitch contact, or open synchronous diverter motor winding (~4.0–6.0 kΩ).

Access water switch module under sump. Measure diverter motor winding (~4.0–6.0 kΩ). Test microswitch continuity when cam lobe activates contact. Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
E07
Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: Drum rotation drive motor failure E07; motor hums without rotating or stops reversing direction mid-program.

On V-ZUG dryers with AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: Defective motor run capacitor (typically 7–16 µF / 450V), open auxiliary motor winding (~18–35 Ω), or welded reversing relay on PCB.

Discharge and test motor capacitor using capacitance meter: replace if below rated capacitance (±5%). Measure main and auxiliary winding resistances (~18–35 Ω). Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E07
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Induction module cooling fan motor stalled or missing tach E07; cooktop shuts down power to prevent heatsink thermal avalanche.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: 12V DC brushless fan impeller jammed by grease or stray wire, disconnected 3-wire fan plug, or blown fan driver transistor on PCB.

Inspect fan blades for physical obstructions. Test fan with 12V DC bench supply: verify smooth spinning and square wave tachometer signal output. Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E07
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Top grill or broil element open circuit E07; upper heating zone does not glow red and browning or grilling fails completely.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Burned-out inner broil or outer bake heating circuit (~18–28 Ω per circuit, combined 2200–2800W) or thermal overload switch open.

Measure resistance across both upper element terminal pairs: inner grill (~20–28 Ω) and outer perimeter (~35–45 Ω). Replace dual element assembly if any loop is open. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E07
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Freezer evaporator circulation fan motor stalled E07; air circulation stops, fresh food compartment warms up, and ice accumulates.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Ice build-up jamming fan blade wheel, seized 12V DC BLDC motor sleeve bearing, or missing feedback tachometer pulse signal.

Melt ice obstruction around fan cowl. Measure DC voltage at fan plug: red/black must supply ~12V DC; yellow must toggle pulse signal (0–5V) when rotating blade. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E07
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Motor drive velocity anomaly E07; control module detects sudden motor acceleration or missing tachometer frequency feedback.

On V-ZUG washing machines featuring AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Loose tachometer coil magnet on motor shaft, open tachometer winding (~65–140 Ω), or shorted motor Triac.

Inspect tachometer magnet tightening on rotor shaft. Measure tachometer winding resistance (~65–140 Ω). Verify motor wiring harness continuity. Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E08
Dishwasher
Water Inlet Valve, Aquastop & Flowmeter

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Water softener circuit fault E08; salt chamber regeneration solenoid valve fails to open during regeneration cycle.

On V-ZUG dishwashers utilizing AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Crystallized salt jamming valve plunger, open regeneration solenoid coil (~3.8–5.2 kΩ), or burnt triac driver.

Inspect regeneration solenoid mounted on side of ion-exchange tank. Measure coil resistance (~3.8–5.2 kΩ). Rinse plunger mechanism to dissolve salt crystals. Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
← Previous PagePage 2 of 6 (165 results)Next Page →

V-Zug — Complete Error Code Catalog

65 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher29

C1E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15F01F02F03F04F05F13F22i10i20i30i50i60iC0

Washing Machine17

A01A02A03A05A06A07A09A10A13A15A16E18E19E20F06F08F14

Tumble Dryer1

E16

Oven / Microwave8

E17E30Er1Er3Er6F3F4F6

Hob / Cooktop5

E9F1F2F5F8

Refrigerator / Freezer5

AL01AL02E1E2E3

Need Help? Call a Certified Technician

Our official certified partners service V-Zug appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy