Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
V-Zug • Central Diagnostic Dictionary
165 Verified Codes in Database

V-Zug Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for V-Zug appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
E13
Dishwasher
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Detergent dispenser actuator error E13; tablet compartment lid fails to release or rinse aid valve does not actuate.

On V-ZUG dishwashers featuring AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Open dispenser release solenoid coil (~1.8–2.8 kΩ or wax motor ~1.5 kΩ), mechanical latch catch warped, or broken wire.

Remove door inner liner screws. Disconnect dispenser coil terminals and measure resistance (~1.8–2.8 kΩ or ~1.5 kΩ). Inspect door hinge wiring. Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
E13
Tumble Dryer
Drainage System & Drain Pump

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: Electronic mainboard memory checksum failure E13; display freezes on error code and machine refuses programming inputs.

On V-ZUG dryers with AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: Non-volatile memory corruption caused by mains transient spikes, defective 5V DC low-voltage rail filter capacitor, or MCU firmware fault.

Disconnect mains power for 10 minutes to drain capacitors. If fault persists after reboot, reflash firmware using service tool or replace configured main electronic module. Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E13
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Bridge flex zone synchronization failure E13; paired induction zones fail to link into unified rectangular cooking surface.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: Phase shift mismatch between front and rear inductor drive circuits, high-speed optocoupler delay, or uneven coil inductance.

Measure inductance of both bridge coils using LCR meter (must match within ±3%). Verify inter-module synchronization link ribbon cable continuity (<0.2 Ω). Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E13
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Combi-steam boiler heating element fault E13; oven operates in dry convection but steam injection modes fail completely.

On V-ZUG combi-steam ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Open steam boiler heating element (~42–58 Ω nominal, 1000–1200W), heavy limescale accumulation, or dry-run safety trip.

Disconnect power. Access steam boiler module. Measure element resistance (~42–58 Ω). Check manual reset Klixon on boiler casing (<0.5 Ω). Perform full descaling cycle. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E13
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Lower machinery compartment condenser fan motor stalled E13; compressor overheats, high pressure rises, and cooling drops drastically.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Heavy carpet lint or pet hair choking fan shroud, seized motor shaft bearings, or burned motor coil (~12V DC or ~220–350 Ω AC).

Disconnect power and remove rear lower access grille. Vacuum dust from condenser coil and fan blades. Verify 12V DC supply or check AC coil continuity. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E13
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Configuration parameter error E13; microcontroller detects checksum mismatch in non-volatile EEPROM memory tables.

On V-ZUG washing machines featuring AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: AC mains brownout during active write operation, electrical storm surge, or degraded EEPROM silicon flash cells.

Disconnect power for 10 minutes. If error persists upon reboot, main control module requires reprogramming via manufacturer service tool or replacement. Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E14
Dishwasher
Heating Element, Thermostat & Safety Fuse

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Active drying system fault E14; zeolite regeneration heater or drying ventilation blower fan fails to engage during dry cycle.

On V-ZUG dishwashers utilizing AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Open zeolite heating element (~30–42 Ω), seized BLDC drying blower bearing, or tripped safety thermal cutout.

Measure zeolite element resistance (~30–42 Ω). Check fan motor winding resistance with multimeter (~180–320 Ω). Verify free blower rotation. Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
E14
Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: Process cooling air blower fan stalled E14; secondary blower fan fails to run, causing internal thermal build-up and emergency shutdown.

On V-ZUG dryers with AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: Foreign object or dense lint jamming fan impeller blades, seized blower motor sleeve bearing, or blown triac on PCB (~120–220 Ω motor coil).

Spin blower wheel by hand to ensure free rotation without binding. Check motor coil resistance (~120–220 Ω). Verify supply voltage is delivered by board when activated. Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E14
Hob / Cooktop
Heating Element, Thermostat & Safety Fuse

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Mains zero-crossing sync circuit failure E14; cooktop cannot time IGBT switching to AC waveform, shutting down all power.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: High-value SMD resistor chain open on mains sensing line (typically 330 kΩ–1 MΩ), defective zero-cross comparator IC, or heavy harmonic line noise.

Inspect high-voltage sensing resistors on power board inlet stage. Verify 100 Hz (or 120 Hz) clock pulses at microcontroller zero-cross input pin with oscilloscope. Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E14
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Steam water feed pump or inlet valve failure E14; steam drawer does not dispense water into steam generator chamber.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Open pump solenoid coil (~2.2–3.6 kΩ), calcified diaphragm check valve preventing suction, or pinched silicone water tube.

Disconnect electrical terminals of water pump. Measure coil resistance (~2.2–3.6 kΩ). Check silicone suction tubes for kinks and unclog drawer docking seal. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E14
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Refrigeration thermodynamic cycle inefficiency E14; compressor operates continuously for >120 minutes with zero cooling temperature drop.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Slow R600a/R134a refrigerant leak in internal aluminium evaporator tubing or partially blocked capillary expansion tube.

Touch compressor discharge pipe: if cold while running, refrigerant charge has escaped. Check suction pipe for frost ball. Certified refrigeration tech required for brazing/recharge. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E14
Washing Machine
Heating Element, Thermostat & Safety Fuse

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Earth leakage safety trip E14; current leakage from heating element sheath to ground exceeds residual safety threshold.

On V-ZUG washing machines utilizing AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Microscopic fissure in tubular stainless steel heater sheath allowing water ingress into magnesium oxide insulation.

Disconnect heater power leads. Use 500V megaohmmeter to test insulation resistance between heater terminal and metal flange (>2 MΩ required; replace if <2 MΩ). Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E15
Dishwasher
Electronic Control Board (PCB) & Bus Communications

V-ZUG AdoraDish / AdoraSpülen V2000-V6000 SteamFinish Dishwasher: Power module DC voltage failure E15; internal switched-mode power supply rail drops below operational threshold (<10.5V DC).

On V-ZUG dishwashers featuring AdoraDish SteamFinish technology, FunctionLight optical projection, and active zeolite condensation adsorption: Degraded filter capacitor on main power board, shorted actuator coil pulling down rail, or defective SMPS IC.

Inspect power board for capacitor bulging or scorched traces. Measure DC voltage on 12V and 5V test points. Disconnect loads individually to locate short. Open door slightly, press and hold the Program Selection sensor for 4 seconds until three acoustic beeps confirm memory reset, then latch door.

Diagnose
E15
Tumble Dryer
Drainage System & Drain Pump

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: External condensate drain backflow or siphon restriction E15; condensate water overflows into base pan or triggers continuous pumping.

On V-ZUG dryers with AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: Kinked or pinched direct-drain rear hose, drain hose inserted too deep into standpipe creating vacuum siphon, or blocked non-return valve.

Verify drain hose is not pushed more than 10 cm into standpipe; use siphon break bracket. Clean inline rubber non-return flapper valve and ensure unkinked hose path. Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E15
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Power management current limiting relay fault E15; cooktop limits cooking power to single zone or refuses to heat at settings above level 4.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: Pitted or burned contacts on power management selector relay, open relay energizing coil (~350–550 Ω), or failed coil driver transistor.

Measure resistance of relay drive coil (~350–550 Ω). Check contact resistance across switched terminals when energized (<0.1 Ω). Replace relay or inverter board. Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E15
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Steam generator water level sensor anomaly E15; oven falsely reports empty water reservoir or overfills boiler chamber.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Conductive mineral scaling bridging dual level probes, reed switch float jammed by sediment, or detached sense wire.

Clean stainless level probe rods with concentrated citric acid descaler. Check float freedom in reservoir. Measure signal wire continuity to electronic board (<0.5 Ω). Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E15
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Multi-temperature convertible pantry drawer sensor fault E15; meat/fish or deli drawer temperature setting cannot be regulated.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Open or shorted NTC sensor embedded in custom-chill drawer housing (~5–10 kΩ at 25°C), or pinched wire harness in drawer rail.

Remove pantry drawer. Check sensor wiring along telescoping rails for chafing. Measure sensor resistance: expected ~16 kΩ at 0°C (~5–10 kΩ at 25°C). Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E15
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Mains undervoltage fault E15; power supply input voltage drops below operational threshold (<185V AC) during cycle.

On V-ZUG washing machines featuring AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Heavy household line load, loose electrical wall socket connections, or undersized extension power cords.

Measure AC voltage at electrical outlet with multimeter (must be 230V ±10%). Remove extension leads. Connect appliance directly into dedicated outlet. Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E16
Tumble Dryer
General System & Mechanical Integration

V-ZUG AdoraDry / AdoraTrocknen V2000-V6000 DualDry Heat Pump Dryer: Automated condenser flush cleaning valve failure E16; self-cleaning wash cycle fails to flush lint from heat pump exchanger.

On V-ZUG dryers with AdoraDry DualDry closed-loop heat pump thermodynamic circuit, EcoManagement, and conductivity sensor strips: Open or shorted solenoid actuator coil on condenser flushing valve (~3.5–4.8 kΩ), mechanical scale calcification, or clogged flush nozzle.

Disconnect valve electrical leads. Measure solenoid coil resistance (~3.5–4.8 kΩ). Inspect water flush distributor channel and clear lint debris with nylon brush. Turn program dial to Stop. Hold the Gentle and Start keys together for 5 seconds until display shows '000', then power cycle the dryer.

Diagnose
E16
Hob / Cooktop
NTC Temperature Sensor & Thermistor

V-ZUG CookTop / FullFlex / DualFlex Swiss Induction Cooktop: Residual heat indicator 'H' stuck illuminated E16; display shows hot glass warning permanently even after cooktop is cold for hours.

On V-ZUG cooktops with FullFlex multi-inductor surface matrix, OptiGlass ultra-hard diamond coating, and optical pan detection: Open or shorted zone temperature sensor holding simulated heat threshold, or microcontroller memory register latchup.

Cut mains power at breaker for 10 minutes to clear register memory. If 'H' returns immediately when power restored, measure zone NTC probe resistance (~100 kΩ at 25°C). Wipe induction glass surface completely dry. Cut mains supply at breaker box for 60 seconds, restore and touch Key Lock for 5 seconds.

Diagnose
E16
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Motorized rotisserie spit drive stall E16; spit does not rotate when inserted into drive coupling during rotisserie program.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Stripped metallic internal gear pinion, burned synchronous rotisserie motor winding (~8–14 kΩ), or spit overloaded beyond weight limit.

Remove spit and inspect rear drive hub. Measure rotisserie motor resistance across terminals (~8–14 kΩ). Verify 230V AC supply arrives at motor in grill mode. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E16
Refrigerator / Freezer
Door Lock Mechanism & Safety Interlock

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Door display to main power board serial communication failure E16; exterior touch interface goes black or flashes communication error.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: Damaged door hinge wire harness flexed repeatedly during door openings, or pin corrosion in top hinge terminal block.

Remove top hinge plastic cover. Inspect multi-pin harness for pinched or broken wires. Test continuity of each line (<0.3 Ω). Verify 12V and 5V DC supplies to door board. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E16
Washing Machine
Drainage System & Drain Pump

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Suds overdosing detected E16; excessive foam buildup inhibits pump drainage and prolongs rinse cycle safety times.

On V-ZUG washing machines utilizing AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Overdosing of high-foaming concentrated detergent, manual hand-wash powder use, or soft water overdosing.

Allow foam to dissipate. Run an empty drum rinse & drain cycle without soap. Clean pressure bell tube. Reduce detergent dosage according to water hardness. Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E17
Oven / Microwave
NTC Temperature Sensor & Thermistor

V-ZUG Combair / Combi-Steam / Miwell V6000 Swiss Luxury Oven: Internal lighting driver or dimmer circuit fault E17; cavity halogen lamps or LED spots flicker constantly or fail to illuminate.

On V-ZUG ovens with Combair / Combi-Steam Electronic Steam System (ESS), climate sensor chamber, and PT1000 platinum probe (~1090 Ω at 25°C): Blown lighting triac on power PCB caused by shorted halogen bulb filament, defective 12V DC switching transformer, or loose lamp socket.

Disconnect power. Remove bulb glass covers; test bulbs with multimeter continuity. Check 12V DC output voltage from light driver module or replace damaged triac PCB. Switch dial to 0 position. Disconnect master circuit breaker on fuse board for 60 seconds, restore power, and re-confirm clock time.

Diagnose
E17
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

V-ZUG SupremeLine / CombiCooler / Cooler V6000 Luxury Refrigerator: Inverter module AC supply undervoltage lockout E17; compressor controller disables motor drive to protect power silicon.

On V-ZUG refrigeration units with SupremeLine dual refrigeration circuits, MonoFiX precision mounting, and multi-zone dynamic air management: AC input voltage falling below 185V AC under heavy compressor starting torque, or degraded bulk DC bus electrolytic capacitors.

Measure AC voltage at electrical outlet under compressor startup. Measure DC bus voltage across bulk capacitors: must read ~310–340V DC smoothly without excessive ripple. Open fresh food door, press and hold the Cold and Alarm Mute touch pads together for 6 seconds until confirmation chime sounds.

Diagnose
E17
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Drum positioning error E17; automatic drum parking sensor fails to align opening flaps with the top access lid.

On V-ZUG washing machines featuring AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Dislodged drum pulley magnet, open Reed switch sensor, or slipping drive belt preventing fine motor indexing.

Inspect drum drive pulley magnet. Test continuity across Reed sensor contacts while rotating pulley by hand. Inspect and tighten motor drive belt. Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E18
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: 3D vibration telemetry fault E18; electronic controller receives out-of-range acceleration signals from chassis motion sensor.

On V-ZUG washing machines utilizing AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Unclipped 3D accelerometer sensor bracket, broken internal piezoelectric bridge, or pinched sensor ribbon cable.

Inspect 3D sensor mounting clip on outer tub. Verify sensor cable harness connections. Measure DC reference voltage at sensor connector (5V DC). Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E19
Washing Machine
Water Inlet Valve, Aquastop & Flowmeter

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Hot water intake fault E19; secondary hot water inlet valve fails to supply water within allocated filling phase.

On V-ZUG washing machines featuring AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Closed hot water tap, sediment-blocked hot inlet filter, or open hot solenoid coil (~3.6–4.6 kΩ).

Check hot water tap supply. Clean the hot inlet hose mesh filter. Measure electrical resistance of hot solenoid coil (~3.6–4.6 kΩ). Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E20
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

V-ZUG AdoraWash / Unimatic V2000-V6000 Swiss Precision Washer: Recirculation spray failure E20; EcoSpray jet pump fails to recirculate detergent solution onto top of laundry load.

On V-ZUG washing machines utilizing AdoraWash vibration absorbing system (VAS), OptiTime energy logic, and brushless synchronous inverter drive: Lint clogging recirculation spray nozzle, seized circulation impeller, or open jet pump winding (~110–180 Ω).

Clear recirculation spray nozzle located at top door bellow. Inspect pump impeller for debris. Measure circulation pump resistance (~110–180 Ω). Turn appliance off with the Main button. Press and hold Start/Pause and Spin Speed simultaneously for 5 seconds until 'Fn' code clears.

Diagnose
E30
Oven / Microwave
Door Lock Mechanism & Safety Interlock

V-Zug E30: Door lock safety interlock fault in Oven / Microwave; door switch contact fails to close or open.

On V-Zug Oven: The door lock mechanism is faulty and cannot confirm the door is securely closed and locked.

On V-Zug Oven: Ensure the door is closed properly. If the error persists, the door lock assembly needs to be serviced or replaced.

Diagnose
← Previous PagePage 4 of 6 (165 results)Next Page →

V-Zug — Complete Error Code Catalog

65 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher29

C1E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15F01F02F03F04F05F13F22i10i20i30i50i60iC0

Washing Machine17

A01A02A03A05A06A07A09A10A13A15A16E18E19E20F06F08F14

Tumble Dryer1

E16

Oven / Microwave8

E17E30Er1Er3Er6F3F4F6

Hob / Cooktop5

E9F1F2F5F8

Refrigerator / Freezer5

AL01AL02E1E2E3

Need Help? Call a Certified Technician

Our official certified partners service V-Zug appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy