DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Bauknecht AL01
FAQ TREEWhat does error code AL01 mean on a Bauknecht appliance?
Bauknecht error code AL01 indicates: Bauknecht ProFresh & Dynamic0° Total NoFrost Refrigerator: Fresh food compartment evaporator NTC thermistor sensor fault AL01; circuit reading out of calibrated limits..
What is the root cause of Bauknecht error code AL01?
The primary root cause for Bauknecht code AL01 is: On Bauknecht refrigerators (Bauknecht Zen Motor Direct Drive brushless BLDC and L1373 / DEA700 power control architecture): Water ingress into thermal sensor epoxy potting, fractured copper leads behind liner, or corrosion on terminal pin J1..
How do I fix or resolve Bauknecht error code AL01?
To resolve error code AL01: Unplug unit. Access sensor behind rear baffle. Measure NTC resistance: nominal ~2.7 kΩ at 25°C, ~7.8 kΩ at 4°C, ~16 kΩ at 0°C. Replace sensor probe. Hold Alarm Reset button for 3 seconds until alarm indicator turns off and evaporator fan resumes normal cycle.
Is it safe to clear Bauknecht error code AL01 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bauknecht code AL01 persists, the physical component causing On Bauknecht refrigerators (Bauknecht Zen Motor Direct Drive brushless BLDC and L1373 / DEA700 power control architecture): Water ingress into thermal sensor epoxy potting, fractured copper leads behind liner, or corrosion on terminal pin J1. must be inspected or replaced.
How do I test electrical resistance for Bauknecht code AL01 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Bauknecht code AL01?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.