OEM VERIFIED BENCH
OFFICIAL FAULT CODEAL
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch AL

Refrigerator / FreezerRefrigeration Compressor, Defrost Heater & PTC Relay
Monolithic French-door smart refrigerator in matte black steel with dual refrigeration zones
Refrigerator / Freezer
Other Brands Sharing Code AL:SiemensALNeffALGaggenauAL

Symptom / Description

FAULT

Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: High temperature cavity alarm AL; freezer temperature has risen above critical threshold of -9°C for over 60 minutes.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bosch refrigerators: Door left ajar for extended period, prolonged household power outage, loss of refrigerant gas charge (leak), or compressor shutdown.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Press Alarm Silence key to mute buzzer. Ensure door seals adhere tightly with no gaps. Check compressor vibration and condenser warmth at rear. Press and hold Super/Alarm Off button for 10 seconds until acoustic chime confirms fault log reset.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLRefrigeration Compressor, Defrost Heater & PTC RelayRefrigerator / Freezer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Compressor Motor Windings (Run/Start) & Defrost Heater
Test Pins & Connections
PROBE (+)
PROBE (-)
Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).
Tolerance & Diagnostic Criteria±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero.
1. Pre-Intervention Electrical Safety Protocols
  • !Refrigeration Safety Protocol: Disconnect mains power before unclipping compressor terminal covers.
  • !Flammable Refrigerant Warning: R600a (isobutane) is flammable. Never puncture cooling tubes or use open flame.
  • !High Surface Temperature: Compressor shell can exceed 80°C during normal operation. Allow to cool before inspection.
3. Preliminary Mechanical & Visual Checks
  • Listen for compressor startup attempts: repetitive clicking every 60 seconds indicates locked rotor or failed PTC relay.
  • Inspect evaporator coil for thick solid frost buildup, signaling defrost heater, sensor, or timer failure.
  • Clean condenser coils and check cooling fan motor for free rotation and dust accumulation.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch AL

FAQ TREE
What does error code AL mean on a Bosch appliance?

Bosch error code AL indicates: Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: High temperature cavity alarm AL; freezer temperature has risen above critical threshold of -9°C for over 60 minutes..

What is the root cause of Bosch error code AL?

The primary root cause for Bosch code AL is: On Bosch refrigerators: Door left ajar for extended period, prolonged household power outage, loss of refrigerant gas charge (leak), or compressor shutdown..

How do I fix or resolve Bosch error code AL?

To resolve error code AL: Press Alarm Silence key to mute buzzer. Ensure door seals adhere tightly with no gaps. Check compressor vibration and condenser warmth at rear. Press and hold Super/Alarm Off button for 10 seconds until acoustic chime confirms fault log reset.

Is it safe to clear Bosch error code AL by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code AL persists, the physical component causing On Bosch refrigerators: Door left ajar for extended period, prolonged household power outage, loss of refrigerant gas charge (leak), or compressor shutdown. must be inspected or replaced.

How do I test electrical resistance for Bosch code AL using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..

What safety protocol must be followed before servicing Bosch code AL?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Refrigerator / Freezer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E01NTC Temperature Sensor & Thermistor
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Fridge compartment...
Inspect Protocol
E02Refrigeration Compressor, Defrost Heater & PTC Relay
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Evaporator defrost...
Inspect Protocol
E03NTC Temperature Sensor & Thermistor
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Chiller / VitaFres...
Inspect Protocol
E04NTC Temperature Sensor & Thermistor
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Ambient room tempe...
Inspect Protocol
E05Refrigeration Compressor, Defrost Heater & PTC Relay
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Freezer compartmen...
Inspect Protocol
E10Refrigeration Compressor, Defrost Heater & PTC Relay
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Compressor inverte...
Inspect Protocol
E11Electronic Control Board (PCB) & Bus Communications
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Display user inter...
Inspect Protocol
E15Refrigeration Compressor, Defrost Heater & PTC Relay
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Defrost heater sys...
Inspect Protocol
E20Refrigeration Compressor, Defrost Heater & PTC Relay
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Inverter compresso...
Inspect Protocol
E21Refrigeration Compressor, Defrost Heater & PTC Relay
Bosch Serie 4 / Serie 6 / Serie 8 VitaFresh pro 0°C NoFrost Refrigerator: Evaporator circula...
Inspect Protocol
d0Door Lock Mechanism & Safety Interlock
Bosch Serie 6 / Serie 8 FlexInduction & PerfectFry Induction Cooktop: Showroom demo mode act...
Inspect Protocol
d1Drive Motor, Inverter & Tachometer Sensor
Bosch Serie 6 / Serie 8 FlexInduction & PerfectFry Induction Cooktop: Front left cooking zon...
Inspect Protocol
d2Door Lock Mechanism & Safety Interlock
Bosch Serie 6 / Serie 8 FlexInduction & PerfectFry Induction Cooktop: Rear left cooking zone...
Inspect Protocol
d3Door Lock Mechanism & Safety Interlock
Bosch Serie 6 / Serie 8 FlexInduction & PerfectFry Induction Cooktop: Center / rear right co...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy