Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEd01
FAGOR
FAGOR // OFFICIAL DIAGNOSTIC BENCH

FAGOR Dishwasher d01

DishwasherWater Level Pressure Switch & Air Dome
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Brandt / Fagor Group: Equivalent Code Across OEM Group Brands
Groupe Brandt / Fagor Shared Electronic Platform
Brandtd01De Dietrichd01Sauterd01
Other Brands Sharing Code d01:ArdoD01BlueskyD01OceanD01SametD01

Symptom / Description

FAULT

Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water fill timeout d01; appliance fails to fill with adequate water volume within 4 minutes of program launch.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Closed water isolation cock, clogged aquastop filter mesh, or open inlet solenoid coil (~3.8 kΩ).

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Inspect tap flow rate. Unscrew hose connection and clean the inline strainer. Measure aquastop solenoid resistance (~3.8 kΩ). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide FAGOR Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Nominal Resistance / Test Range
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.
Test Harness Pins
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Level Pressure Switch & Air DomeDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Test Pins & Connections
PROBE (+)
PROBE (-)
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Tolerance & Diagnostic CriteriaMechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Cut 230V mains power before accessing the upper chassis or pressure switch terminals.
  • !Drain appliance tub completely before disconnecting pressure switch sensing hoses.
  • !Never blow high-pressure compressed air into electronic analog pressure sensors: internal diaphragms will rupture!
3. Preliminary Mechanical & Visual Checks
  • Disconnect the silicone pressure tube from the lower air trap and inspect for soap sludge, lint, or water blockage.
  • Inspect the flexible rubber hose along its entire length for pinholes, cracks, or loose clamp fit.
  • Thoroughly flush the lower compression chamber (air dome) with hot water to dissolve detergent buildup.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: FAGOR D01

FAQ TREE
What does error code D01 mean on a FAGOR appliance?

FAGOR error code D01 indicates: Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water fill timeout d01; appliance fails to fill with adequate water volume within 4 minutes of program launch..

What is the root cause of FAGOR error code D01?

The primary root cause for FAGOR code D01 is: On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Closed water isolation cock, clogged aquastop filter mesh, or open inlet solenoid coil (~3.8 kΩ)..

How do I fix or resolve FAGOR error code D01?

To resolve error code D01: Inspect tap flow rate. Unscrew hose connection and clean the inline strainer. Measure aquastop solenoid resistance (~3.8 kΩ). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.

Is it safe to clear FAGOR error code D01 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if FAGOR code D01 persists, the physical component causing On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Closed water isolation cock, clogged aquastop filter mesh, or open inlet solenoid coil (~3.8 kΩ). must be inspected or replaced.

How do I test electrical resistance for FAGOR code D01 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..

What safety protocol must be followed before servicing FAGOR code D01?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does FAGOR error code d01 mean on a Dishwasher?

FAGOR error code d01 on a Dishwasher indicates: Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water fill timeout d01; appliance fails to fill with adequate water volume within 4 minutes of program launch.. Primary cause: On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Closed water isolation cock, clogged aquastop filter mesh, or open inlet solenoid coil (~3.8 kΩ).. Recommended solution: Inspect tap flow rate. Unscrew hose connection and clean the inline strainer. Measure aquastop solenoid resistance (~3.8 kΩ). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off..

What does FAGOR error code d01 mean on a Tumble Dryer?

FAGOR error code d01 on a Tumble Dryer indicates: Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Condensation water reservoir full d01; dryer halts cycle and triggers acoustic water tank warning.. Primary cause: On FAGOR tumble dryers utilizing Innova thermodynamic refrigeration circuit, dual conductivity sensor bars, and reversible drum rotation: Full water recovery tank, stuck polystyrene float microswitch, or obstructed condensate drain tube.. Recommended solution: Empty upper condensation drawer. Inspect lower float switch chamber and remove lint fluff. Test float microswitch with a multimeter. Turn dial to Off position, hold Start and Anti-Crease buttons together for 6 seconds until buzzer beeps, then turn back on..

What does FAGOR error code d01 mean on a Refrigerator / Freezer?

FAGOR error code d01 on a Refrigerator / Freezer indicates: Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Fridge compartment temperature sensor failure d01; internal cold air temperature fluctuates uncontrollably.. Primary cause: On FAGOR refrigeration units featuring Innova Total No Frost dual-evaporator system, dynamic cooling column, and intelligent automated defrost cycle: Open circuit, shorted NTC thermistor, or moisture ingress in the refrigerator cavity sensor harness.. Recommended solution: Measure the refrigerator NTC resistance: expect approx. 5.0 kΩ at 25°C or 16.3 kΩ at 0°C. If reading is infinite (open) or zero (short), replace the sensor kit. Press and hold the Super Freeze and Alarm Mute pads together for 6 seconds until the beep confirms diagnostic memory cleared..

What does FAGOR error code d01 mean on a Washing Machine?

FAGOR error code d01 on a Washing Machine indicates: Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Water intake timeout d01; tub water level does not reach wash threshold within 6 minutes of valve opening.. Primary cause: On FAGOR washing machines featuring Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Low mains pressure (<0.5 bar), blocked inlet filter screen, kinked hose, or open dual solenoid valve coil (~3.8 kΩ).. Recommended solution: Check mains tap pressure (>10 L/min). Clean the inlet hose filter. Measure resistance of both solenoid coils (~3.8 kΩ). Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart..

Community Verification

COMMUNITY

Did this solution resolve the issue?

FAGOR d01 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

FAGOR d01 — Dishwasher

[ACTIVE]
Symptom / Description:

Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water fill timeout d01; appliance fails to fill with adequate water volume within 4 minutes of program launch.

Root Cause:

On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Closed water isolation cock, clogged aquastop filter mesh, or open inlet solenoid coil (~3.8 kΩ).

Repair Instructions:

Inspect tap flow rate. Unscrew hose connection and clean the inline strainer. Measure aquastop solenoid resistance (~3.8 kΩ). Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.

FAGOR d01 — Dryer

Symptom / Description:

Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Condensation water reservoir full d01; dryer halts cycle and triggers acoustic water tank warning.

Root Cause:

On FAGOR tumble dryers utilizing Innova thermodynamic refrigeration circuit, dual conductivity sensor bars, and reversible drum rotation: Full water recovery tank, stuck polystyrene float microswitch, or obstructed condensate drain tube.

Repair Instructions:

Empty upper condensation drawer. Inspect lower float switch chamber and remove lint fluff. Test float microswitch with a multimeter. Turn dial to Off position, hold Start and Anti-Crease buttons together for 6 seconds until buzzer beeps, then turn back on.

FAGOR d01 — Refrigerator / Freezer

Symptom / Description:

Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Fridge compartment temperature sensor failure d01; internal cold air temperature fluctuates uncontrollably.

Root Cause:

On FAGOR refrigeration units featuring Innova Total No Frost dual-evaporator system, dynamic cooling column, and intelligent automated defrost cycle: Open circuit, shorted NTC thermistor, or moisture ingress in the refrigerator cavity sensor harness.

Repair Instructions:

Measure the refrigerator NTC resistance: expect approx. 5.0 kΩ at 25°C or 16.3 kΩ at 0°C. If reading is infinite (open) or zero (short), replace the sensor kit. Press and hold the Super Freeze and Alarm Mute pads together for 6 seconds until the beep confirms diagnostic memory cleared.

FAGOR d01 — Washing Machine

Symptom / Description:

Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Water intake timeout d01; tub water level does not reach wash threshold within 6 minutes of valve opening.

Root Cause:

On FAGOR washing machines featuring Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Low mains pressure (<0.5 bar), blocked inlet filter screen, kinked hose, or open dual solenoid valve coil (~3.8 kΩ).

Repair Instructions:

Check mains tap pressure (>10 L/min). Clean the inlet hose filter. Measure resistance of both solenoid coils (~3.8 kΩ). Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart.

SEMANTIC KNOWLEDGE GRAPH // FAGOR

Related FAGOR Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

d02Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Drain pump timeout d02; dirty wash water r...
Inspect Protocol
d03Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash heating system failure d03; water rem...
Inspect Protocol
d04Dishwasher
NTC Temperature Sensor & Thermistor
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump NTC temperature thermistor fault d04;...
Inspect Protocol
d05Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash circulation pump stall d05; main wash...
Inspect Protocol
d06Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash motor overcurrent cutoff d06; power e...
Inspect Protocol
d07Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: AquaSafe anti-flood base pan float trigger...
Inspect Protocol
d08Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Alternating spray distributor valve motor ...
Inspect Protocol
d09Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Internal control bus communication error d...
Inspect Protocol
d10Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous uncontrolled water fill d10; wa...
Inspect Protocol
d11Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Pressure switch chamber clogged d11; water...
Inspect Protocol
d12Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Dynamic water level loss d12; water level ...
Inspect Protocol
d13Dishwasher
NTC Temperature Sensor & Thermistor
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water temperature overheating cutoff d13; ...
Inspect Protocol
d14Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash pump cavitation / water fill discrepa...
Inspect Protocol
F1Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water inlet pressure drop error F1; flowme...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy