Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEd07
FAGOR
FAGOR // OFFICIAL DIAGNOSTIC BENCH

FAGOR Dishwasher d07

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Brandt / Fagor Group: Equivalent Code Across OEM Group Brands
Groupe Brandt / Fagor Shared Electronic Platform
Brandtd07De Dietrichd07Sauterd07
Other Brands Sharing Code d07:ArdoD07BlueskyD07OceanD07SametD07

Symptom / Description

FAULT

Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: AquaSafe anti-flood base pan float triggered d07; machine halts wash cycle and forces continuous drain pumpout.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On FAGOR dishwashers utilizing Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Water accumulation in lower retention tray due to leaking sump O-ring, perforated hose, or tripped polystyrene float.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect power. Sponge dry the base tray under the appliance. Locate and repair the active water drip. Verify microswitch opens cleanly. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide FAGOR Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: FAGOR D07

FAQ TREE
What does error code D07 mean on a FAGOR appliance?

FAGOR error code D07 indicates: Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: AquaSafe anti-flood base pan float triggered d07; machine halts wash cycle and forces continuous drain pumpout..

What is the root cause of FAGOR error code D07?

The primary root cause for FAGOR code D07 is: On FAGOR dishwashers utilizing Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Water accumulation in lower retention tray due to leaking sump O-ring, perforated hose, or tripped polystyrene float..

How do I fix or resolve FAGOR error code D07?

To resolve error code D07: Disconnect power. Sponge dry the base tray under the appliance. Locate and repair the active water drip. Verify microswitch opens cleanly. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.

Is it safe to clear FAGOR error code D07 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if FAGOR code D07 persists, the physical component causing On FAGOR dishwashers utilizing Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Water accumulation in lower retention tray due to leaking sump O-ring, perforated hose, or tripped polystyrene float. must be inspected or replaced.

How do I test electrical resistance for FAGOR code D07 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing FAGOR code D07?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does FAGOR error code d07 mean on a Dishwasher?

FAGOR error code d07 on a Dishwasher indicates: Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: AquaSafe anti-flood base pan float triggered d07; machine halts wash cycle and forces continuous drain pumpout.. Primary cause: On FAGOR dishwashers utilizing Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Water accumulation in lower retention tray due to leaking sump O-ring, perforated hose, or tripped polystyrene float.. Recommended solution: Disconnect power. Sponge dry the base tray under the appliance. Locate and repair the active water drip. Verify microswitch opens cleanly. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off..

What does FAGOR error code d07 mean on a Tumble Dryer?

FAGOR error code d07 on a Tumble Dryer indicates: Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Air circulation restriction detected d07; airflow differential pressure drops significantly across condenser heat exchanger.. Primary cause: On FAGOR tumble dryers utilizing Innova thermodynamic refrigeration circuit, dual conductivity sensor bars, and reversible drum rotation: Heavy lint compaction on fine mesh door filters, or blocked aluminum condenser fin channels.. Recommended solution: Remove and wash lint filters under warm running water. Extract condenser block and flush with shower spray to clear all fin channels. Turn dial to Off position, hold Start and Anti-Crease buttons together for 6 seconds until buzzer beeps, then turn back on..

What does FAGOR error code d07 mean on a Refrigerator / Freezer?

FAGOR error code d07 on a Refrigerator / Freezer indicates: Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Condenser cooling fan motor failure d07; compressor overheats, trips overload protector, and cooling stops.. Primary cause: On FAGOR refrigeration units featuring Innova Total No Frost dual-evaporator system, dynamic cooling column, and intelligent automated defrost cycle: Heavy lint/dust clogging lower condenser grille, seized fan shaft, or disconnected 230V/12V fan power cable.. Recommended solution: Clean dust from lower condenser coil and fan blades. Check for free rotation. Test voltage at fan motor terminals during active compressor cycle. Replace seized fan motor. Press and hold the Super Freeze and Alarm Mute pads together for 6 seconds until the beep confirms diagnostic memory cleared..

What does FAGOR error code d07 mean on a Washing Machine?

FAGOR error code d07 on a Washing Machine indicates: Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Door interlock safety fault d07; cycle will not begin because electronic module cannot confirm closed door contact.. Primary cause: On FAGOR washing machines utilizing Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Defective bi-metal PTC door latch mechanism (~800–1200 Ω), misaligned strike hook, or pitted safety contacts.. Recommended solution: Check door latch engagement. Measure resistance across PTC terminals of the interlock (~800–1200 Ω). Verify 230V AC arrival on trigger. Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart..

Community Verification

COMMUNITY

Did this solution resolve the issue?

FAGOR d07 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

FAGOR d07 — Dishwasher

[ACTIVE]
Symptom / Description:

Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: AquaSafe anti-flood base pan float triggered d07; machine halts wash cycle and forces continuous drain pumpout.

Root Cause:

On FAGOR dishwashers utilizing Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Water accumulation in lower retention tray due to leaking sump O-ring, perforated hose, or tripped polystyrene float.

Repair Instructions:

Disconnect power. Sponge dry the base tray under the appliance. Locate and repair the active water drip. Verify microswitch opens cleanly. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.

FAGOR d07 — Dryer

Symptom / Description:

Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Air circulation restriction detected d07; airflow differential pressure drops significantly across condenser heat exchanger.

Root Cause:

On FAGOR tumble dryers utilizing Innova thermodynamic refrigeration circuit, dual conductivity sensor bars, and reversible drum rotation: Heavy lint compaction on fine mesh door filters, or blocked aluminum condenser fin channels.

Repair Instructions:

Remove and wash lint filters under warm running water. Extract condenser block and flush with shower spray to clear all fin channels. Turn dial to Off position, hold Start and Anti-Crease buttons together for 6 seconds until buzzer beeps, then turn back on.

FAGOR d07 — Refrigerator / Freezer

Symptom / Description:

Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Condenser cooling fan motor failure d07; compressor overheats, trips overload protector, and cooling stops.

Root Cause:

On FAGOR refrigeration units featuring Innova Total No Frost dual-evaporator system, dynamic cooling column, and intelligent automated defrost cycle: Heavy lint/dust clogging lower condenser grille, seized fan shaft, or disconnected 230V/12V fan power cable.

Repair Instructions:

Clean dust from lower condenser coil and fan blades. Check for free rotation. Test voltage at fan motor terminals during active compressor cycle. Replace seized fan motor. Press and hold the Super Freeze and Alarm Mute pads together for 6 seconds until the beep confirms diagnostic memory cleared.

FAGOR d07 — Washing Machine

Symptom / Description:

Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Door interlock safety fault d07; cycle will not begin because electronic module cannot confirm closed door contact.

Root Cause:

On FAGOR washing machines utilizing Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Defective bi-metal PTC door latch mechanism (~800–1200 Ω), misaligned strike hook, or pitted safety contacts.

Repair Instructions:

Check door latch engagement. Measure resistance across PTC terminals of the interlock (~800–1200 Ω). Verify 230V AC arrival on trigger. Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart.

SEMANTIC KNOWLEDGE GRAPH // FAGOR

Related FAGOR Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

d08Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Alternating spray distributor valve motor ...
Inspect Protocol
d09Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Internal control bus communication error d...
Inspect Protocol
d10Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous uncontrolled water fill d10; wa...
Inspect Protocol
d11Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Pressure switch chamber clogged d11; water...
Inspect Protocol
d12Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Dynamic water level loss d12; water level ...
Inspect Protocol
d13Dishwasher
NTC Temperature Sensor & Thermistor
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water temperature overheating cutoff d13; ...
Inspect Protocol
d14Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash pump cavitation / water fill discrepa...
Inspect Protocol
F1Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water inlet pressure drop error F1; flowme...
Inspect Protocol
F2Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump water evacuation timeout F2; water re...
Inspect Protocol
F3Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Heating system malfunction F3; temperature...
Inspect Protocol
F4Dishwasher
NTC Temperature Sensor & Thermistor
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Sump NTC sensor open or short circuit F4; ...
Inspect Protocol
F5Dishwasher
Drainage System & Drain Pump
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Circulation wash motor electrical fault F5...
Inspect Protocol
F6Dishwasher
Water Level Pressure Switch & Air Dome
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous water entry / water level safet...
Inspect Protocol
i20Dishwasher
Drainage System & Drain Pump
Fagor Dishwasher beeps and stops with fault code 'i20'; dirty water remains pooled in the bo...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy