OFFICIAL FAULT CODEE70
Faure
Faure // OFFICIAL DIAGNOSTIC BENCH

Faure E70

Washing MachineNTC Temperature Sensor & Thermistor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Washing Machine
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code E70:ElectroluxE70AEGE70ZanussiE70Arthur MartinE70PhilipsE70CastorE70FrigidaireE70WestinghouseE70ZoppasE70

Symptom / Description

FAULT

Faure FWG / FWF Series / Magic'45 Compact Washer: Temperature sensor general alarm E70; temperature measurement circuit out of plausible range.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Wash NTC sensor out of tolerance, corroded pins on NTC connector, broken wire in harness, or defective ADC input channel on MCU.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Measure NTC resistance at room temperature 20°C (nominal 4.8–6.0 kΩ; at 60°C ~1.2 kΩ). Clean connector contacts with contact cleaner. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Faure Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorWashing Machine
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Faure E70

FAQ TREE
What does error code E70 mean on a Faure appliance?

Faure error code E70 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Temperature sensor general alarm E70; temperature measurement circuit out of plausible range..

What is the root cause of Faure error code E70?

The primary root cause for Faure code E70 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Wash NTC sensor out of tolerance, corroded pins on NTC connector, broken wire in harness, or defective ADC input channel on MCU..

How do I fix or resolve Faure error code E70?

To resolve error code E70: Measure NTC resistance at room temperature 20°C (nominal 4.8–6.0 kΩ; at 60°C ~1.2 kΩ). Clean connector contacts with contact cleaner. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.

Is it safe to clear Faure error code E70 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E70 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Wash NTC sensor out of tolerance, corroded pins on NTC connector, broken wire in harness, or defective ADC input channel on MCU. must be inspected or replaced.

How do I test electrical resistance for Faure code E70 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Faure code E70?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FAURE

Related Faure Washing Machine Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E71NTC Temperature Sensor & Thermistor
Faure FWG / FWF Series / Magic'45 Compact Washer: Wash NTC thermistor open or short circuit ...
Inspect Protocol
E72NTC Temperature Sensor & Thermistor
Faure FWG / FWF Series / Magic'45 Compact Washer: Drying condenser NTC sensor fault E72 on w...
Inspect Protocol
E73NTC Temperature Sensor & Thermistor
Faure FWG / FWF Series / Magic'45 Compact Washer: Drying air duct NTC sensor fault E73 on wa...
Inspect Protocol
E74NTC Temperature Sensor & Thermistor
Faure FWG / FWF Series / Magic'45 Compact Washer: Wash NTC sensor misplaced or loose in tub ...
Inspect Protocol
E80Heating Element, Thermostat & Safety Fuse
Faure FWG / FWF Series / Magic'45 Compact Washer: Program selector dial general fault E80; p...
Inspect Protocol
E82Electronic Control Board (PCB) & Bus Communications
Faure FWG / FWF Series / Magic'45 Compact Washer: Program selector position encoding error E...
Inspect Protocol
E83Electronic Control Board (PCB) & Bus Communications
Faure FWG / FWF Series / Magic'45 Compact Washer: Program selector reading error while cycle...
Inspect Protocol
E84Drive Motor, Inverter & Tachometer Sensor
Faure FWG / FWF Series / Magic'45 Compact Washer: Recirculation wash pump triac sensing circ...
Inspect Protocol
E85Drive Motor, Inverter & Tachometer Sensor
Faure FWG / FWF Series / Magic'45 Compact Washer: Recirculation pump triac damaged or motor ...
Inspect Protocol
E90Electronic Control Board (PCB) & Bus Communications
Faure FWG / FWF Series / Magic'45 Compact Washer: Electronic control configuration general m...
Inspect Protocol
E91Electronic Control Board (PCB) & Bus Communications
Faure FWG / FWF Series / Magic'45 Compact Washer: UI to main board communication error E91; ...
Inspect Protocol
E92Electronic Control Board (PCB) & Bus Communications
Faure FWG / FWF Series / Magic'45 Compact Washer: Protocol incongruence between UI and main ...
Inspect Protocol
E93Electronic Control Board (PCB) & Bus Communications
Faure FWG / FWF Series / Magic'45 Compact Washer: Configuration code mismatch E93; appliance...
Inspect Protocol
E94Electronic Control Board (PCB) & Bus Communications
Faure FWG / FWF Series / Magic'45 Compact Washer: Cycle configuration parameter error E94; s...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy