Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Rosieres ER02
FAQ TREEWhat does error code ER02 mean on a Rosieres appliance?
Rosieres error code ER02 indicates: Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor short circuit Er02; measured resistance across probe terminals drops below 100 Ω threshold..
What is the root cause of Rosieres error code ER02?
The primary root cause for Rosieres code ER02 is: On Rosières ovens powered by French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Pinching of probe lead wires by rear metal backplate screws, crushed fiberglass sleeving, or internal short in sensing bulb..
How do I fix or resolve Rosieres error code ER02?
To resolve error code ER02: Inspect wiring harness from probe to PCB for pinched insulation. Verify probe resistance disconnected from PCB (nominal ~538 Ω / ~1078 Ω at 20°C). Return oven selectors to 0, switch off the kitchen circuit breaker for 60 seconds, re-engage and reset the rotary clock timer.
Is it safe to clear Rosieres error code ER02 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code ER02 persists, the physical component causing On Rosières ovens powered by French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Pinching of probe lead wires by rear metal backplate screws, crushed fiberglass sleeving, or internal short in sensing bulb. must be inspected or replaced.
How do I test electrical resistance for Rosieres code ER02 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Rosieres code ER02?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?