Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Sauter ER02
FAQ TREEWhat does error code ER02 mean on a Sauter appliance?
Sauter error code ER02 indicates: Sauter Saveurs / Confort / Amphora / SFP Pyrolytic Oven: Cavity high-temperature limit exceeded Er02; oven safety system triggers after cavity exceeds 320°C in non-pyrolytic baking mode..
What is the root cause of Sauter error code ER02?
The primary root cause for Sauter code ER02 is: On Sauter built-in ovens featuring Saveurs gentle convection airflow, Conseil Température cooking guide, and Amphora enamel heat reflection: Welded heating element relay on power PCB feeding current continuously, or drifted PT500 probe..
How do I fix or resolve Sauter error code ER02?
To resolve error code ER02: Cut mains power immediately and let oven cool down. Test heater relay contacts with power disconnected (must be open). Check PT500 resistance. Turn selector to Off, drop power at the branch breaker for 60 seconds, restore supply and touch the clock icon to recalibrate.
Is it safe to clear Sauter error code ER02 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Sauter code ER02 persists, the physical component causing On Sauter built-in ovens featuring Saveurs gentle convection airflow, Conseil Température cooking guide, and Amphora enamel heat reflection: Welded heating element relay on power PCB feeding current continuously, or drifted PT500 probe. must be inspected or replaced.
How do I test electrical resistance for Sauter code ER02 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..
What safety protocol must be followed before servicing Sauter code ER02?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



