Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
De Dietrich • Central Diagnostic Dictionary
130 Verified Codes in Database

De Dietrich Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for De Dietrich appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
Er06
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Main power board communication timeout Er06; display module loses digital data exchange with the internal power relay board.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Loosened data ribbon harness, electrical interference spikes, or dropped 12V DC auxiliary supply rail.

Reseat multi-core data harness connecting user interface and relay power PCB. Measure 12V DC and 5V DC supply rails on test pads. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er07
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: EEPROM memory configuration error Er07; oven parameters fail boot verification and controls freeze.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Corrupted non-volatile EEPROM storage sector caused by power grid surge during active baking.

Isolate mains breaker for 15 minutes to force microcomputer memory cold boot. If Er07 persists on power up, replace main control board. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er08
Oven / Microwave
NTC Temperature Sensor & Thermistor

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Meat probe temperature sensor fault Er08; core food probe reads short-circuit or abnormal value when plugged into internal socket.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Internal jack socket grease contamination, punctured probe cable insulation, or damaged probe thermistor tip.

Unplug probe. Clean female jack receptacle inside oven with electronics cleaner. Measure resistance across probe plug pins with a multimeter. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er09
Oven / Microwave
NTC Temperature Sensor & Thermistor

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Combi-steam boiler generator fault Er09; steam generator dry-boil thermal protection or NTC thermistor error detected.

On De Dietrich steam combi ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Heavy mineral limescale obstructing boiler heat transfer, open steam heater (~45–60 Ω), or defective boiler NTC (~10 kΩ at 25°C).

Execute automated descaling procedure with commercial sulfamic acid descaler. Measure boiler heating element resistance (~45–60 Ω) and boiler NTC (~10 kΩ at 25°C). Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er10
Oven / Microwave
Drainage System & Drain Pump

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Steam boiler water evacuation fault Er10; drain pump fails to pump residual water out of the steam boiler.

On De Dietrich steam combi ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Calcium flakes wedging the mini drain pump impeller, blocked silicone drain tube, or open pump coil (~150–220 Ω).

Inspect mini drainage pump below steam generator. Clear scale obstructions from pump chamber. Measure pump coil resistance (~150–220 Ω). Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er11
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Upper heating grill element relay fault Er11; top grill element glows red continuously without cooking program active.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Welded or arced grill power relay contacts on the main power relay circuit board.

Disconnect mains breaker immediately. Measure grill element resistance (~22–26 Ω). Test relay contacts with power off; replace power relay PCB if shorted. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er12
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Lower heating sole element relay fault Er12; bottom oven cavity continues heating unchecked regardless of thermostat setting.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Welded relay contacts on lower bake heating circuit on main power board.

Isolate breaker. Measure bottom bake element resistance (~35–45 Ω). Measure continuity across bake relay contacts with power off (must be open). Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er13
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Circular convection fan heating element open circuit Er13; convection forced air mode blows air without heating.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Burned-out circular calrod heating element surrounding the rear convection fan (~25–32 Ω).

Disconnect power and remove rear internal fan shroud inside oven cavity. Measure resistance across circular element terminals (~25–32 Ω). Replace element. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er14
Oven / Microwave
General System & Mechanical Integration

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Capacitive touch panel continuous keypress error Er14; touch control button registers continuous contact for longer than 10 seconds.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Greasy residue, condensation film over glass front, or detached conductive foam spacer under glass.

Clean front glass panel with a microfiber cloth and glass cleaner. Ensure hands are dry. Power cycle circuit breaker for 60 seconds to recalibrate capacitance. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
Er15
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Electronics housing ambient overtemperature Er15; onboard PCB ambient thermal sensor registers temperatures exceeding 85°C.

On De Dietrich built-in ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Defective tangential cooling blower, blocked cabinetry ventilation chimney, or damaged upper heat deflector.

Turn off oven and allow cooling. Ensure kitchen cabinet has minimum 50mm rear ventilation gap. Verify tangential cooling fan runs freely. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
F0
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: No cookware detected or unsuitable pan base F0; zone display alternates 'F0' and heating output is withheld.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Non-ferromagnetic cookware (copper, pure aluminum, ceramic glass), or warped base diameter smaller than 120mm.

Use an induction-compatible pan with a thick flat steel or cast-iron base. Verify with a refrigerator magnet (must stick securely to pan bottom). Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F01
Oven / Microwave
NTC Temperature Sensor & Thermistor

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Temperature sensor probe open circuit F01; controller senses completely broken cavity temperature sensor loop.

On De Dietrich ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Broken internal PT500 RTD platinum filament, disconnected connector behind rear insulation, or fractured probe wires.

Unplug oven from power. Measure probe resistance (~540 Ω at 20°C). Inspect sensor wiring behind rear fiberglass blanket. Replace probe if open. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
F01
Washing Machine
Water Inlet Valve, Aquastop & Flowmeter

De Dietrich Prestige / DWF Inverter Washing Machine: Basque electronic platform water fill fault F01; water inlet solenoid valve fails to supply water within allocated timeout.

On De Dietrich washing machines featuring Prestige DWF brushless inverter drive, optoelectronic water metering, and anti-vibration cabinet damping: Closed external supply tap, clogged inlet hose mesh, or open inlet solenoid coil (~3.8 kΩ).

Verify tap water pressure. Remove and rinse the mesh filter screen at the rear valve inlet. Measure coil resistance (~3.8 kΩ). Touch the Power button off, touch and hold Option and Start keys together for 6 seconds until 'rSt' illuminates, then cycle mains power.

Diagnose
F1
Dishwasher
Water Inlet Valve, Aquastop & Flowmeter

De Dietrich Quattro / Space / DFI Luxury Built-in Dishwasher: Water inlet pressure drop error F1; flowmeter impeller does not register incoming pulses during filling phase.

On De Dietrich dishwashers featuring Quattro 4-level hydraulic spray distribution, ICS turbidity assessment, and 42dB acoustic encapsulation: Closed tap, clogged inlet valve screen, stuck flowmeter turbine, or defective reed contact on air break.

Open tap fully. Clean inline filter screen. Measure reed switch pulse closure with a multimeter while water enters air break. Press and hold Programme Selection and Start buttons for 5 seconds until all cycle lights illuminate steadily, then switch off power.

Diagnose
F1
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: User interface keyboard communication timeout F1; touch control panel loses synchronization with induction power board.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Oxidized ribbon cable pin headers, electrical line transient spikes, or defective 5V DC low-voltage regulator.

Inspect multi-strand cable linking touch panel to power module. Measure 5V DC on logic supply test pads. Reseat connectors firmly. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F1
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

De Dietrich Prestige No Frost / DRS Multi-Zone Refrigerator: Defrost evaporator sensor error F1; freezer display blinks warning code and defrost cycle does not terminate properly.

On De Dietrich refrigeration units featuring Prestige No Frost multi-sensor refrigeration, active preservation zone, and inverter compressor modulation: Fagor Innova platform evaporator NTC sensor out of ohmic range, broken wire harness in cabinet foaming, or plug oxidation.

Measure evaporator NTC resistance at board plug: approx. 10.0 kΩ at 25°C and 32.5 kΩ at 0°C. If value deviates by >15%, replace the probe using service repair kit. Touch and hold the Alarm Acknowledge and Quick Chill icons for 8 seconds until the ICS chime signals buffer reset, then release.

Diagnose
F02
Oven / Microwave
NTC Temperature Sensor & Thermistor

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Temperature sensor probe short circuit F02; controller registers zero resistance on cavity thermal loop.

On De Dietrich ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Pinch in braided high-temperature leads, crushed probe sheath touching cavity chassis, or internal short in RTD element.

Disconnect sensor at PCB plug. Measure resistance across pins (must not be zero; nominal ~540 Ω at 20°C). Inspect wiring harness for chassis contact. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
F2
Dishwasher
Drainage System & Drain Pump

De Dietrich Quattro / Space / DFI Luxury Built-in Dishwasher: Sump water evacuation timeout F2; water remains detected in the bottom sump basin after drain phase timing expires.

On De Dietrich dishwashers featuring Quattro 4-level hydraulic spray distribution, ICS turbidity assessment, and 42dB acoustic encapsulation: Blocked sink spigot connection, debris in drain pump volute, or open drain pump winding (~180–220 Ω).

Check sink drain connector and punch out membrane if newly installed. Measure drain pump motor resistance (~180–220 Ω). Press and hold Programme Selection and Start buttons for 5 seconds until all cycle lights illuminate steadily, then switch off power.

Diagnose
F2
Hob / Cooktop
NTC Temperature Sensor & Thermistor

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: Induction coil thermal probe circuit anomaly F2; cooking zone halts heating immediately after detecting open or shorted NTC.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Fractured coil center thermistor glass bead (~100 kΩ at 25°C), or wire severance under coil mounting disc.

Disconnect coil thermistor plug from power module. Measure resistance across probe leads (~100 kΩ at 25°C). Replace central coil sensor if damaged. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F2
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

De Dietrich Prestige No Frost / DRS Multi-Zone Refrigerator: Refrigerator compartment air temperature probe failure F2; display alternates temperature and fault code.

On De Dietrich refrigeration units featuring Prestige No Frost multi-sensor refrigeration, active preservation zone, and inverter compressor modulation: Open-circuit or short-circuit in the refrigerator compartment NTC thermistor sensor, or disconnected harness.

Check sensor resistance at pins on main PCB: nominal 5.0 kΩ at 25°C and 16.3 kΩ at 0°C. If open or shorted, install service replacement NTC probe. Touch and hold the Alarm Acknowledge and Quick Chill icons for 8 seconds until the ICS chime signals buffer reset, then release.

Diagnose
F03
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Tangential cooling fan speed error F03; fan operates at insufficient RPM or tachometer signal is missing.

On De Dietrich ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Degraded blower motor run winding, dusty fan bearings, or failed Hall sensor IC.

Clean fan roller of lint and dust. Measure motor coil resistance (~240–320 Ω). Verify tachometer signal line voltage (pulses 0–5V DC). Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
F3
Dishwasher
Water Level Pressure Switch & Air Dome

De Dietrich Quattro / Space / DFI Luxury Built-in Dishwasher: Heating system malfunction F3; temperature fails to climb during wash segment, aborting heating cycle.

On De Dietrich dishwashers featuring Quattro 4-level hydraulic spray distribution, ICS turbidity assessment, and 42dB acoustic encapsulation: Open heater resistance element (~25–28 Ω), blown inline thermal fuse, or open safety pressure switch.

Measure heating element terminals for continuity (~25–28 Ω). Verify safety pressure switch closes when circulation pump creates water pressure. Press and hold Programme Selection and Start buttons for 5 seconds until all cycle lights illuminate steadily, then switch off power.

Diagnose
F3
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: High voltage surge protection active F3; power board shuts down induction frequency generation to prevent semiconductor destruction.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Lightning strike transient, sudden line inductive load switching, or missing neutral on 400V 3-phase hookup.

Isolate cooktop for 10 minutes. Check supply voltage across all terminals (must be steady 230V AC to Neutral). Ensure neutral is connected solidly. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F3
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

De Dietrich Prestige No Frost / DRS Multi-Zone Refrigerator: Freezer compartment air temperature probe failure F3; freezer temperature control loses precision and warning flashes.

On De Dietrich refrigeration units featuring Prestige No Frost multi-sensor refrigeration, active preservation zone, and inverter compressor modulation: Freezer air NTC sensor failure, wire harness pinch at cabinet bottom, or moisture infiltration into sensor body.

Measure freezer sensor resistance: expected approx. 10.0 kΩ at 25°C, 32.5 kΩ at 0°C, and 85 kΩ at -18°C. Replace sensor if resistance does not match temperature curve. Touch and hold the Alarm Acknowledge and Quick Chill icons for 8 seconds until the ICS chime signals buffer reset, then release.

Diagnose
F04
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Pyrolytic door lock motor drive failure F04; latch actuator fails to reach locked position within 60 seconds.

On De Dietrich ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Open actuator motor coil (~4.8 kΩ), cracked reduction gears, or door hook misalignment.

Check door latch motor coil resistance (~4.8 kΩ). Verify latch mechanism rotates freely without binding against chassis sheet metal. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
F4
Dishwasher
NTC Temperature Sensor & Thermistor

De Dietrich Quattro / Space / DFI Luxury Built-in Dishwasher: Sump NTC sensor open or short circuit F4; controller senses disconnected or shorted thermal sensor circuit.

On De Dietrich dishwashers featuring Quattro 4-level hydraulic spray distribution, ICS turbidity assessment, and 42dB acoustic encapsulation: Defective NTC thermistor element (~47 kΩ at 25°C), disconnected wiring harness, or moisture bridging pins.

Unplug NTC sensor from sump. Measure resistance across probe pins (~47 kΩ at 25°C). Inspect wiring harness for pin push-back. Press and hold Programme Selection and Start buttons for 5 seconds until all cycle lights illuminate steadily, then switch off power.

Diagnose
F4
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: Generator DC bus undervoltage trip F4; internal filtered rectified voltage collapses under induction pulse load.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Degraded primary bridge rectifier, dried-out high-voltage DC filter electrolytic capacitors, or poor supply terminal connection.

Check mains terminal block screw torque. Measure rectified DC bus voltage across bulk capacitors (must maintain >290V DC under zone operation). Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F4
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

De Dietrich Prestige No Frost / DRS Multi-Zone Refrigerator: Defrost heater cycle timeout F4; maximum defrost heating duration exceeded without reaching cutout temperature.

On De Dietrich refrigeration units featuring Prestige No Frost multi-sensor refrigeration, active preservation zone, and inverter compressor modulation: Defective calrod defrost element (~280 Ω), open thermal fuse (72°C), or poor thermal contact of defrost NTC on evaporator.

Measure defrost heater: expect ~260–300 Ω. Measure inline thermal safety fuse: must read 0 Ω. Confirm defrost NTC is tightly clamped to the evaporator tube. Touch and hold the Alarm Acknowledge and Quick Chill icons for 8 seconds until the ICS chime signals buffer reset, then release.

Diagnose
F05
Oven / Microwave
General System & Mechanical Integration

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Pyrolytic latch microswitch position error F05; position feedback microswitch does not toggle when door unlatches.

On De Dietrich ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: Sticky microswitch actuator plunger, oxidized switch contacts, or bent actuator leaf spring.

Test microswitch continuity with a multimeter in both unlatched (~0 Ω) and latched (infinite) positions. Replace microswitch if sticky. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
F5
Dishwasher
Drive Motor, Inverter & Tachometer Sensor

De Dietrich Quattro / Space / DFI Luxury Built-in Dishwasher: Circulation wash motor electrical fault F5; wash pump fails to run and cycle stalls during wash stages.

On De Dietrich dishwashers featuring Quattro 4-level hydraulic spray distribution, ICS turbidity assessment, and 42dB acoustic encapsulation: Open motor windings (~70–110 Ω), defective starting capacitor (~4 µF), or tripped motor thermal protector.

Measure wash motor winding resistance (~70–110 Ω). Check run capacitor rating with a capacitance meter (~4 µF). Verify 230V AC arrival on call. Press and hold Programme Selection and Start buttons for 5 seconds until all cycle lights illuminate steadily, then switch off power.

Diagnose
← Previous PagePage 4 of 5 (130 results)Next Page →

De Dietrich — Complete Error Code Catalog

73 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher20

d01d02d03d04d05d06d07d08d09d10d11d12d13d14F1F2F3F4F5F6

Washing Machine7

d21d22d23d24d25d26d27

Tumble Dryer6

d15d16d17d18d19d20

Oven / Microwave23

Er00Er01Er02Er03Er04Er05Er06Er07Er08Er09Er10Er11Er12Er13Er14Er15F01F02F03F04F05F10SAFE

Hob / Cooktop14

ASE1E2E3E4E5E6E7E8E9F0F7F8F9

Refrigerator / Freezer3

AL01AL02AL03

Need Help? Call a Certified Technician

Our official certified partners service De Dietrich appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy