Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
De Dietrich • Central Diagnostic Dictionary
130 Verified Codes in Database

De Dietrich Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for De Dietrich appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
F5
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: Induction power stage thermal overload F5; cooling fan cannot dissipate heat quickly enough, triggering thermal power foldback.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Sustained maximum power boiling across all zones simultaneously with restricted under-counter ventilation channel.

Reduce cooking zone power levels. Open cabinet doors temporarily to exhaust hot trapped air. Ensure front cooling ventilation gap is unblocked. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F5
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

De Dietrich Prestige No Frost / DRS Multi-Zone Refrigerator: Evaporator fan motor feedback failure F5; fan motor does not achieve target operating RPM during cooling demand.

On De Dietrich refrigeration units featuring Prestige No Frost multi-sensor refrigeration, active preservation zone, and inverter compressor modulation: Heavy ice build-up impeding fan blades, seized motor sleeve bushings, or defective Hall-effect RPM feedback circuit.

Manually defrost evaporator cavity. Spin fan wheel by hand to verify free movement. Measure 12V DC power and frequency on Hall tacho wire during operation. Replace fan assembly. Touch and hold the Alarm Acknowledge and Quick Chill icons for 8 seconds until the ICS chime signals buffer reset, then release.

Diagnose
F6
Dishwasher
Water Level Pressure Switch & Air Dome

De Dietrich Quattro / Space / DFI Luxury Built-in Dishwasher: Continuous water entry / water level safety fault F6; water continues to rise after program attempts shut-off.

On De Dietrich dishwashers featuring Quattro 4-level hydraulic spray distribution, ICS turbidity assessment, and 42dB acoustic encapsulation: Mechanically stuck inlet valve seat, shorted triac on power board, or blocked pressure sensor hose.

Disconnect mains power and check if water stops entering (if yes, electronic triac short; if no, mechanical valve failure). Replace component. Press and hold Programme Selection and Start buttons for 5 seconds until all cycle lights illuminate steadily, then switch off power.

Diagnose
F6
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: Short-circuited IGBT power semiconductor F6; circuit breaker trips with an audible pop when zone is turned on.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Collector-to-emitter semiconductor breakdown on IGBT due to voltage spike or thermal fatigue under load.

Disconnect cooktop from breaker. Disassemble power unit and test IGBTs on heatsink with multimeter on diode test (~0V = blown). Replace power module. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F6
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

De Dietrich Prestige No Frost / DRS Multi-Zone Refrigerator: Door display communication fault F6; user interface loses digital connection to the main power board.

On De Dietrich refrigeration units featuring Prestige No Frost multi-sensor refrigeration, active preservation zone, and inverter compressor modulation: Severed or pinched wires inside the top door hinge bushing, oxidized connector pins, or faulty transceiver on display PCB.

Inspect door hinge wiring harness: check each wire for breakages caused by door swinging. Clean multi-pin connectors with contact cleaner. Replace display module if wiring tests OK. Touch and hold the Alarm Acknowledge and Quick Chill icons for 8 seconds until the ICS chime signals buffer reset, then release.

Diagnose
F7
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: Cooling fan blocked or low RPM stall F7; electronic safety cuts zone power when fan fails to achieve operational speed.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Grease accumulation seizing fan spindle, dislodged internal sound baffle, or open motor coil winding (~40–80 Ω).

Clean fan impeller blades and bearing spindle with alcohol. Measure motor coil resistance (~40–80 Ω). Verify free spin by hand. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F8
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: Continuous pan sensing resonance failure F8; induction coil pulses loudly but cannot sustain stable magnetic field coupling.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Cookware with non-uniform sandwich composite base, cracked resonance capacitor bank on power PCB, or burned Litz coil wire.

Switch to a solid heavy cast iron skillet to test coil coupling. Inspect resonance capacitors on PCB for bulging or scorch marks. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F9
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

De Dietrich Piano Zoneless / Horizone / DPI Induction Cooktop: Control board EEPROM calibration checksum failure F9; factory power table values are corrupted and zones will not operate.

On De Dietrich cooktops utilizing Piano full-surface zoneless induction matrix, 16-level power modulation, and Boil function boilover prevention: Power line voltage surge corrupting non-volatile flash memory cells on touch microprocessor board.

Disconnect power circuit breaker for 15 minutes. Reconnect power and observe if calibration reloads; replace touch controller PCB if code persists. Clear the ceramic surface, turn off the dedicated breaker for 60 seconds, restore supply and touch the Key Lock sensor for 5 seconds.

Diagnose
F10
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

De Dietrich Fascination Pyrolytic Oven stops during pyrolytic cycle and locks door, flashing error 'F10'.

Chassis temperature exceeded safe ceiling (overheat switch open) due to cooling turbine stall or obstructed air exhaust ducts.

Allow oven to cool 60 minutes. Check upper exhaust grille clearance. Test overheat limiter continuity (0 Ω). Reset mechanical thermostat button.

Diagnose
SAFE
Oven / Microwave
General System & Mechanical Integration

De Dietrich ICS (Intelligent Cooking System) / Fascination / Corium Pyrolytic Oven: Child safety control lock active SAFE; display shows 'SAFE' and oven controls are locked against accidental activation.

On De Dietrich ovens featuring ICS sensor-guided automated culinary cooking, PT500 platinum thermal probe (~540 Ω at 20°C), and 480°C Pyro-Turbo cleaning: User-activated child lock feature, or long accidental press on the Key pad or Clock icon.

Touch and hold the Key icon or Clock button firmly for 5 seconds until an audible beep confirms deactivation and 'SAFE' extinguishes. Rotate rotary knob to zero, disconnect power at the master breaker panel for 90 seconds, re-engage and validate time on the ICS interface.

Diagnose
← Previous PagePage 5 of 5 (130 results)
Next Page →

De Dietrich — Complete Error Code Catalog

73 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher20

d01d02d03d04d05d06d07d08d09d10d11d12d13d14F1F2F3F4F5F6

Washing Machine7

d21d22d23d24d25d26d27

Tumble Dryer6

d15d16d17d18d19d20

Oven / Microwave23

Er00Er01Er02Er03Er04Er05Er06Er07Er08Er09Er10Er11Er12Er13Er14Er15F01F02F03F04F05F10SAFE

Hob / Cooktop14

ASE1E2E3E4E5E6E7E8E9F0F7F8F9

Refrigerator / Freezer3

AL01AL02AL03

Need Help? Call a Certified Technician

Our official certified partners service De Dietrich appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.