OEM VERIFIED BENCH
OFFICIAL FAULT CODEF13
Bompani
Bompani // OFFICIAL DIAGNOSTIC BENCH

Bompani F13

OvenNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code F13:MieleF13WhirlpoolF13IndesitF13BauknechtF13V-ZugF13AristonF13BrandtF13LiebherrF13HisenseF13SchulthessF13

Symptom / Description

FAULT

Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational diagnostic fault code F13 signaled by internal electronics. Lower bottom bake heating element open circuit or high resistance (1300W, nominal 38-44 Ω)

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Bompani kitchen suites engineered with PT1000 cavity RTD sensor (1080 Ω at 20°C), bi-directional tangential cooling fan, motorized pyrolytic door lock, and 2300W convection circular element: Internal heating spiral burned open, thermal insulation sagging, or spade connector scorched by heat Multimeter diagnostic parameter: nominal resistance 38 Ω to 44 Ω at 20°C; infinite resistance indicates open circuit breakdown.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Safely de-energize the appliance at the electrical distribution board. Unplug wiring connector from the affected component and verify with a digital multimeter: gain access to lower chassis housing and measure resistance directly across the bottom element spades. Inspect spade lugs for signs of heat discoloration. Replace defective component, restore electrical supply, and perform system reset: Turn oven selector knob to OFF position. Press and hold Temp and Timer buttons simultaneously for 5 seconds until 'rSt' flashes, then press Start to confirm memory wipe.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bompani Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bompani F13

FAQ TREE
What does error code F13 mean on a Bompani appliance?

Bompani error code F13 indicates: Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational diagnostic fault code F13 signaled by internal electronics. Lower bottom bake heating element open circuit or high resistance (1300W, nominal 38-44 Ω).

What is the root cause of Bompani error code F13?

The primary root cause for Bompani code F13 is: On Bompani kitchen suites engineered with PT1000 cavity RTD sensor (1080 Ω at 20°C), bi-directional tangential cooling fan, motorized pyrolytic door lock, and 2300W convection circular element: Internal heating spiral burned open, thermal insulation sagging, or spade connector scorched by heat Multimeter diagnostic parameter: nominal resistance 38 Ω to 44 Ω at 20°C; infinite resistance indicates open circuit breakdown..

How do I fix or resolve Bompani error code F13?

To resolve error code F13: Safely de-energize the appliance at the electrical distribution board. Unplug wiring connector from the affected component and verify with a digital multimeter: gain access to lower chassis housing and measure resistance directly across the bottom element spades. Inspect spade lugs for signs of heat discoloration. Replace defective component, restore electrical supply, and perform system reset: Turn oven selector knob to OFF position. Press and hold Temp and Timer buttons simultaneously for 5 seconds until 'rSt' flashes, then press Start to confirm memory wipe.

Is it safe to clear Bompani error code F13 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bompani code F13 persists, the physical component causing On Bompani kitchen suites engineered with PT1000 cavity RTD sensor (1080 Ω at 20°C), bi-directional tangential cooling fan, motorized pyrolytic door lock, and 2300W convection circular element: Internal heating spiral burned open, thermal insulation sagging, or spade connector scorched by heat Multimeter diagnostic parameter: nominal resistance 38 Ω to 44 Ω at 20°C; infinite resistance indicates open circuit breakdown. must be inspected or replaced.

How do I test electrical resistance for Bompani code F13 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Bompani code F13?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOMPANI

Related Bompani Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F14NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F15NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F16NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F17NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F18NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F19NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F20NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F21NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F22NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F23NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F24NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F25NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F26NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
F27NTC Temperature Sensor & Thermistor
Bompani Serie Divina / Linea Built-in Multifunction Pyrolytic & Convection Oven: Operational...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy