FAGOR d10 — Dishwasher
[ACTIVE]Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous uncontrolled water fill d10; water continues entering appliance after target fill level is achieved.
On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Debris wedging inlet valve plunger open, shorted inlet triac on PCB, or leaking valve diaphragm.
Shut off water tap immediately. Check if water continues flowing with power turned off (proves mechanical valve seat leak). Replace inlet valve. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.